2021-02-26 06:08:33 -0500 | commented answer | Natural ventilation result equal to zero Thanks for the answer! I am already using AirflowNetwork objects for natural ventilation. To use Fan: ZoneExhaust do I n |
2021-02-24 12:13:42 -0500 | commented question | Natural ventilation result equal to zero Added. I am using Energy Plus 8.6 |
2021-02-24 12:00:58 -0500 | received badge | ● Disciplined (source) |
2021-02-24 12:00:32 -0500 | asked a question | Natural ventilation result equal to zero Natural ventilation result equal to zero I am modeling a project that is totally naturally ventilated, in the results of |
2021-01-25 06:12:34 -0500 | asked a question | Natural Ventilation Output Objects for LEED Natural Ventilation Output Objects for LEED Hello guys, I have a fully natural ventilation project to LEED V4, this is |
2020-10-07 14:02:40 -0500 | asked a question | Baseline fan airflow rates sized based on a 20 deg. F supply-air-to-room-air temperature difference Baseline fan airflow rates sized based on a 20 deg. F supply-air-to-room-air temperature difference Hi there, I have a |
2020-05-26 10:35:19 -0500 | marked best answer | Modelling Natural ventilation for LEED v4 Hi everyone, I am modelling an industrial case that has only natural ventilation in the design building. I searched in LEED and ASHRAE for some guidance to do the baseline building when the proposed model has only natural ventilation, but i haven't found some clarifying answers. Can anyone help? What is expected to do in baseline buildings when the design building has only natural ventilation? |
2020-05-13 08:05:09 -0500 | asked a question | Modelling Natural ventilation for LEED v4 Modelling Natural ventilation for LEED v4 Hi everyone, I am modelling an industrial case that has only natural ventila |
2020-05-07 08:43:17 -0500 | received badge | ● Enthusiast |
2020-03-16 08:06:04 -0500 | commented answer | Error importing gbxml in OpenStudio Thank you, David. I saw this, I don't know why the geometry look like this way, because in ARCHICAD the zones are made e |
2020-03-16 08:01:35 -0500 | commented answer | Error importing gbxml in OpenStudio Thank you, David. I saw this, I don't know why the geometry look like this way, because in ARCHICAD the zones are made e |
2020-03-13 14:00:26 -0500 | asked a question | Number of baseline Chillers - LEED v4 Number of baseline Chillers - LEED v4 Hi, I have a baseline model from a restaurant that is a combination of System 7 a |
2020-03-12 08:48:45 -0500 | commented answer | Diffuse skylight in DesignBuilder Thank you. I will try this. |
2020-03-11 12:58:27 -0500 | asked a question | Diffuse skylight in DesignBuilder Diffuse skylight in DesignBuilder Hello, Can I consider a polycarbonate skylight Diffuser System in daylight calculatio |
2020-03-10 13:30:31 -0500 | commented question | Error importing gbxml in OpenStudio I saw this forum. But I haven't tested yet |
2020-03-10 13:24:41 -0500 | commented question | Error importing gbxml in OpenStudio I will send it. I am using OpenStudio 2.8, and the model was design in Archicad 23. |
2020-03-08 19:08:16 -0500 | edited question | Error importing gbxml in OpenStudio Error importing gbxml in OpenStudio Hi, I have a model in a gbxml file but when I tried to merge the model with OpenStu |
2020-03-08 19:07:54 -0500 | edited question | Error importing gbxml in OpenStudio Error importing gbxml in OpenStudio Hi, I have a model in a gbxml file but when I tried to merge the model with OpenStu |
2020-03-08 19:07:16 -0500 | asked a question | Error importing gbxml in OpenStudio Error importing gbxml in OpenStudio Hi, I have a model in a gbxml file but when I tried to merge the model with OpenStu |
2020-03-03 14:11:39 -0500 | asked a question | Fan Power Minimum Flow Fraction changes Fan Power Minimum Flow Fraction changes Hello, I am a new OpenStudio user and I am modelling a full service restaurant t |
2020-02-20 13:14:04 -0500 | received badge | ● Editor (source) |
2020-02-20 13:14:04 -0500 | edited question | Outdoor Air Zone Inputs Outdoor Air Zone Inputs Hi, I was wondering if it's possible set Minimum Outdoor Air flow to HVAC zones in DesignBuilde |
2020-02-20 13:11:03 -0500 | asked a question | Outdoor Air Zone Inputs Outdoor Air Zone Inputs Hi, I was wondering if it's possible set Minimum Outdoor Air flow to HVAC zones in DesignBuilde |
2020-01-16 13:20:38 -0500 | asked a question | Simulation performance outputs Simulation performance outputs Hi, I have a Proposed Model with VRF HVAC System and the baseline match systems are syst |
2020-01-16 04:55:34 -0500 | commented answer | ASHRAE 90.1/2010 G3.1.3.12 Interpretation Thanks a lot. It was very helpful |
2020-01-16 04:54:29 -0500 | marked best answer | ASHRAE 90.1/2010 G3.1.3.12 Interpretation Hi, I'm new in energy modelling and I received a note from a energy model reviewer (LEED) regarding my Baseline energy model that is supposed to be in accordance with Section G3.1.3.12 ASHRAE 90.1/2010. The G3.1.3.12 says : Supply Air Temperature Reset (Systems 5 through 8). The air temperature for cooling shall be reset higher by 5°F under the minimum cooling load conditions. My baseline model is a system 7 and 8, and the building type is a full service restaurant. I had some doubts about the Section G3.1.3.12 interpretation, it's related to the setpoit manager? Can I use the setpoint manager warmest with the difference between minimum setpoint temperature and maximum setpoint temperature being 5°F? Any help is appreciated |
2020-01-16 04:54:28 -0500 | received badge | ● Scholar (source) |
2020-01-15 10:59:22 -0500 | received badge | ● Supporter (source) |
2020-01-15 07:46:32 -0500 | commented answer | ASHRAE 90.1/2010 G3.1.3.12 Interpretation Thank you for your answer. What are the correct values that I have to set in minimum setpoint temperature and maximum se |
2020-01-15 07:07:39 -0500 | received badge | ● Student (source) |
2020-01-14 13:48:31 -0500 | commented question | ASHRAE 90.1/2010 G3.1.3.12 Interpretation I am using DesignBuilder |
2020-01-14 13:45:25 -0500 | received badge | ● Organizer (source) |
2020-01-14 13:39:43 -0500 | asked a question | ASHRAE 90.1/2010 G3.1.3.12 Interpretation ASHRAE 90.1/2010 G3.1.3.12 Interpretation Hi, I'm new in energy modelling and I received a note from a energy model rev |