First time here? Check out the Help page!
2021-04-22 11:29:34 -0500 | marked best answer | Forcing an upgrade to have zero unmet hours Using PAT Tool v.2.8.0 with ResStock's project_singlefamilydetached to run analyses. Was wondering if there's a way to force PAT tool to create an end-use load profile where there are zero unmet hours?
I'm currently using the My objective is to run PAT tool with any HVAC system and observe the end-use load profile on the basis that it can meet heating load 100% of the time out of the year. |
2020-06-22 00:14:30 -0500 | edited question | RECS Data Used For Housing Characteristics? RECS Data Used For Housing Characteristics Observing the CHANGELOG for ResStock (https://github.com/NREL/OpenStudio-Buil |
2020-06-22 00:14:24 -0500 | edited question | RECS Data Used For Housing Characteristics? RECS Status of Housing Characteristics Observing the CHANGELOG for ResStock (https://github.com/NREL/OpenStudio-BuildSto |
2020-06-22 00:14:02 -0500 | asked a question | RECS Data Used For Housing Characteristics? RECS Status of Housing Characteristics Observing the CHANGELOG for ResStock (https://github.com/NREL/OpenStudio-BuildSto |
2020-06-16 22:12:02 -0500 | edited question | MSHP and 2-speed ASHP expend more energy than single-speed ASHP? MSHP and 2-speed ASHP expend more energy than ASHP? Using ResStock 2.2.4, OpenStudio 2.9.0, and EnergyPlus 9.2 I'm find |
2020-06-16 22:12:02 -0500 | received badge | ● Editor (source) |
2020-06-15 09:45:57 -0500 | asked a question | MSHP and 2-speed ASHP expend more energy than single-speed ASHP? MSHP and 2-speed ASHP expend more energy than ASHP? Using ResStock 2.2.4, OpenStudio 2.9.0, and EnergyPlus 9.2 I'm find |
2020-06-12 10:41:34 -0500 | commented answer | Decision Logic for Supplementary Heating of ASHP So for ASHP's in particular, supplementary heating operation is decided by min_temp instead of heating load? Furthermore |
2020-06-10 16:29:29 -0500 | edited question | Decision Logic for Supplementary Heating of ASHP Decision Logic for Supplementary Electric Resistance Heating Using ResStock 2.2.4, OpenStudio 2.9.0, EnergyPlus 9.2 For |
2020-06-10 16:29:08 -0500 | asked a question | Decision Logic for Supplementary Heating of ASHP Decision Logic for Supplementary Electric Resistance Heating Using ResStock 2.2.4, OpenStudio 2.9.0, EnergyPlus 9.2 For |
2020-06-10 16:14:13 -0500 | commented question | recovering old results files I don't believe so. Every time you run a new analysis in PAT, the contents within your localResults folder is emptied ou |
2020-06-08 10:35:50 -0500 | received badge | ● Commentator |
2020-06-08 10:35:50 -0500 | commented answer | High unmet cooling hours for finished basements served by central cooling systems What methods would you suggest to tackle first in correcting for this issue? Is there a way to alter the basement supply |
2020-06-07 17:08:19 -0500 | asked a question | High unmet cooling hours for finished basements served by central cooling systems Centralized Cooling Results in Unmet Hours For Finished Basement Using ResStock v2.2.4 with OpenStudio v.2.9.0 and Energ |
2020-05-22 10:18:19 -0500 | asked a question | Incremental Cost and Savings for Upgrades Incremental Cost and Savings for Upgrades Context: Using OpenStudio-Buildstock v.2.2.3 Using project_singlefamilydetac |
2020-04-12 14:16:16 -0500 | commented question | Forcing an upgrade to have zero unmet hours The following is the OS result for an Electric Baseboard upgrade without the oversizing: Time Setpoint Not Met Time ( |
2020-03-28 16:47:50 -0500 | asked a question | Modeling WSHP w/DOAS on Parametric Analysis Tool Modeling WSHP w/DOAS on Parametric Analysis Tool I'm using the "Replace HVAC with WSHP and DOAS" OpenStudio measure with |
2020-03-25 21:19:42 -0500 | received badge | ● Enthusiast |
2020-03-07 17:17:27 -0500 | asked a question | Forcing an upgrade to have zero unmet hours Forcing an upgrade to have zero unmet hours Using PAT Tool v.2.8.0 with ResStock's project_singlefamilydetached to run a |
2020-01-22 18:24:32 -0500 | asked a question | Some upgrade options aren't compatible with ResStock? Some upgrade options aren't compatible with ResStock? Context: Using Parametric Analysis Tool to run analyses using pr |
2020-01-10 13:26:22 -0500 | answered a question | Using own weather files in PAT tool Using weather file zip locally will not work (i.e. from your own machine). What I found worked was taking the desired zi |
2020-01-10 13:23:23 -0500 | commented answer | Using own weather files in PAT tool Thank you! Yes, uploading the zipped weather files into Dropbox, and using the download link to the respective files, se |
2019-12-26 14:43:37 -0500 | asked a question | Using own weather files in PAT tool Using own weather files in PAT tool I would like to run PAT tool analysis on project_singlefamilydetached using TMY2 and |
2019-12-06 14:15:39 -0500 | commented answer | What does changing seed value in Algorithm Settings do? It worked! Changing the seed value in the ruby script does in fact change my results. Thank you! |
2019-12-05 20:34:59 -0500 | asked a question | What does changing seed value in Algorithm Settings do? What does changing seed value in Algorithm Settings do? Context: I am working with project_singlefamilydetached from t |
2019-11-09 16:25:55 -0500 | commented answer | Best variables to use to capture hour-by-hour COP Thank you! Yes, when I use the HEATING COIL HEATING ENERGY and HEATING COIL ELECTRIC ENERGY output, I receive more reaso |
2019-11-05 07:31:30 -0500 | received badge | ● Student (source) |
2019-11-03 21:08:09 -0500 | asked a question | Best variables to use to capture hour-by-hour COP Best variables to use to capture hour-by-hour COP I am trying to capture the instantaneous COP of various HVAC system up |
2019-10-24 16:44:59 -0500 | commented answer | Determining the heating load that's independent of upgrade choice How would I compare electric baseboard heat with the propane furnace upgrade? Wouldn't I just run into the same problems |
2019-10-24 16:44:26 -0500 | commented answer | Determining the heating load that's independent of upgrade choice How would I compare electric baseboard heat with the propane furnace upgrade? Wouldn't I just run into the same problems |
2019-10-23 15:24:48 -0500 | commented answer | Determining the heating load that's independent of upgrade choice Thank you for your insight Eric. I tried comparing coil heat output variables, and there are still times when the values |
2019-10-23 14:04:40 -0500 | commented answer | Determining the heating load that's independent of upgrade choice Thank you for your insight Eric. I tried comparing coil heat output variables, and there are still times when the values |
2019-10-22 20:19:58 -0500 | commented answer | Determining the heating load that's independent of upgrade choice How would I simulate with IdealLoadsAirSystems using Parametric Analysis Tool + ResStock directory? There is no "IdealLo |
2019-10-21 14:53:55 -0500 | asked a question | Determining the heating load that's independent of upgrade choice Determining the heating load that's independent of upgrade choice I've been working with the project_singlefamilydetache |
2019-10-16 11:32:48 -0500 | received badge | ● Teacher (source) |
2019-10-16 08:47:39 -0500 | answered a question | Difference between editing buildstock.csv versus location + location-region.tsv? So, in experience so far, editing the buildstock.csv versus the locations.tsv and locations-region.tsv has no difference |
2019-10-01 17:38:45 -0500 | commented answer | Apply Upgrade gets rid of Building Characteristics Report? Thank you so much! The github solution worked! |
2019-09-30 15:11:11 -0500 | marked best answer | Apply Upgrade gets rid of Building Characteristics Report? Hello everyone, I'm loading project_singlefamilydetached from ResStock into the Parametric Analysis Tool, and an issue I'm running into is that whenever I have an upgrade applied, my results.csv file does not produce ANY entries for the building_characteristics_report columns. Entries for simulation_output_report columns are produced fine, and I see my upgrade name filled out in the "simulation_output_report.upgrade_name" column, so I know my entry for Apply Upgrade is not being ignored. However, when I choose to skip the Apply Upgrade measures, THEN my results.csv file produces entries for the building_characteristics_report columns. Is anyone else experiencing this issue? I really don't know what the problem is, since I have the "Building Characteristics Report" measure unchecked for both situations. |
2019-09-30 15:11:11 -0500 | received badge | ● Scholar (source) |
2019-09-27 16:02:25 -0500 | asked a question | Apply Upgrade gets rid of Building Characteristics Report? Apply Upgrade gets rid of Building Characteristics Report? Hello everyone, I'm loading project_singlefamilydetached fro |
2019-09-22 10:23:56 -0500 | received badge | ● Supporter (source) |
2019-09-20 15:30:32 -0500 | commented question | Difference between editing buildstock.csv versus location + location-region.tsv? Apologies, to clarify, when I say "anything I put in Apply Upgrade won't go through", I mean that my results.csv file do |
2019-09-20 08:26:25 -0500 | asked a question | Difference between editing buildstock.csv versus location + location-region.tsv? Difference between editing buildstock.csv versus location + location-region.tsv? Context: Using "project_singlefamilyd |