2021-04-22 11:29:34 -0500 marked best answer Forcing an upgrade to have zero unmet hours

Using PAT Tool v.2.8.0 with ResStock's project_singlefamilydetached to run analyses.

Was wondering if there's a way to force PAT tool to create an end-use load profile where there are zero unmet hours? I'm currently using the ASHP, SEER 16, 9.0 HSPF upgrade option on a building stock that's fixed in a IECC Climate Zone 6 area. There are some buildings that will have up to 30% of the year having hours that do not meet the heating setpoint temperature. During some of these hours, the zone air temperature and the zone thermostat temperature will differ by up to 10° F.

My objective is to run PAT tool with any HVAC system and observe the end-use load profile on the basis that it can meet heating load 100% of the time out of the year.

2020-06-22 00:14:30 -0500 edited question RECS Data Used For Housing Characteristics?

RECS Data Used For Housing Characteristics Observing the CHANGELOG for ResStock (https://github.com/NREL/OpenStudio-Buil

2020-06-22 00:14:24 -0500 edited question RECS Data Used For Housing Characteristics?

RECS Status of Housing Characteristics Observing the CHANGELOG for ResStock (https://github.com/NREL/OpenStudio-BuildSto

2020-06-22 00:14:02 -0500 asked a question RECS Data Used For Housing Characteristics?

RECS Status of Housing Characteristics Observing the CHANGELOG for ResStock (https://github.com/NREL/OpenStudio-BuildSto

2020-06-16 22:12:02 -0500 edited question MSHP and 2-speed ASHP expend more energy than single-speed ASHP?

MSHP and 2-speed ASHP expend more energy than ASHP? Using ResStock 2.2.4, OpenStudio 2.9.0, and EnergyPlus 9.2 I'm find

2020-06-16 22:12:02 -0500 received badge  Editor (source)
2020-06-15 09:45:57 -0500 asked a question MSHP and 2-speed ASHP expend more energy than single-speed ASHP?

MSHP and 2-speed ASHP expend more energy than ASHP? Using ResStock 2.2.4, OpenStudio 2.9.0, and EnergyPlus 9.2 I'm find

2020-06-12 10:41:34 -0500 commented answer Decision Logic for Supplementary Heating of ASHP

So for ASHP's in particular, supplementary heating operation is decided by min_temp instead of heating load? Furthermore

2020-06-10 16:29:29 -0500 edited question Decision Logic for Supplementary Heating of ASHP

Decision Logic for Supplementary Electric Resistance Heating Using ResStock 2.2.4, OpenStudio 2.9.0, EnergyPlus 9.2 For

2020-06-10 16:29:08 -0500 asked a question Decision Logic for Supplementary Heating of ASHP

Decision Logic for Supplementary Electric Resistance Heating Using ResStock 2.2.4, OpenStudio 2.9.0, EnergyPlus 9.2 For

2020-06-10 16:14:13 -0500 commented question recovering old results files

I don't believe so. Every time you run a new analysis in PAT, the contents within your localResults folder is emptied ou

2020-06-08 10:35:50 -0500 received badge  Commentator
2020-06-08 10:35:50 -0500 commented answer High unmet cooling hours for finished basements served by central cooling systems

What methods would you suggest to tackle first in correcting for this issue? Is there a way to alter the basement supply

2020-06-07 17:08:19 -0500 asked a question High unmet cooling hours for finished basements served by central cooling systems

Centralized Cooling Results in Unmet Hours For Finished Basement Using ResStock v2.2.4 with OpenStudio v.2.9.0 and Energ

2020-05-22 10:18:19 -0500 asked a question Incremental Cost and Savings for Upgrades

Incremental Cost and Savings for Upgrades Context: Using OpenStudio-Buildstock v.2.2.3 Using project_singlefamilydetac

2020-04-12 14:16:16 -0500 commented question Forcing an upgrade to have zero unmet hours

The following is the OS result for an Electric Baseboard upgrade without the oversizing: Time Setpoint Not Met Time (

2020-03-28 16:47:50 -0500 asked a question Modeling WSHP w/DOAS on Parametric Analysis Tool

Modeling WSHP w/DOAS on Parametric Analysis Tool I'm using the "Replace HVAC with WSHP and DOAS" OpenStudio measure with

2020-03-25 21:19:42 -0500 received badge  Enthusiast
2020-03-07 17:17:27 -0500 asked a question Forcing an upgrade to have zero unmet hours

Forcing an upgrade to have zero unmet hours Using PAT Tool v.2.8.0 with ResStock's project_singlefamilydetached to run a

2020-01-22 18:24:32 -0500 asked a question Some upgrade options aren't compatible with ResStock?

Some upgrade options aren't compatible with ResStock? Context: Using Parametric Analysis Tool to run analyses using pr

2020-01-10 13:26:22 -0500 answered a question Using own weather files in PAT tool

Using weather file zip locally will not work (i.e. from your own machine). What I found worked was taking the desired zi

2020-01-10 13:23:23 -0500 commented answer Using own weather files in PAT tool

Thank you! Yes, uploading the zipped weather files into Dropbox, and using the download link to the respective files, se

2019-12-26 14:43:37 -0500 asked a question Using own weather files in PAT tool

Using own weather files in PAT tool I would like to run PAT tool analysis on project_singlefamilydetached using TMY2 and

2019-12-06 14:15:39 -0500 commented answer What does changing seed value in Algorithm Settings do?

It worked! Changing the seed value in the ruby script does in fact change my results. Thank you!

2019-12-05 20:34:59 -0500 asked a question What does changing seed value in Algorithm Settings do?

What does changing seed value in Algorithm Settings do? Context: I am working with project_singlefamilydetached from t

2019-11-09 16:25:55 -0500 commented answer Best variables to use to capture hour-by-hour COP

Thank you! Yes, when I use the HEATING COIL HEATING ENERGY and HEATING COIL ELECTRIC ENERGY output, I receive more reaso

2019-11-05 07:31:30 -0500 received badge  Student (source)
2019-11-03 21:08:09 -0500 asked a question Best variables to use to capture hour-by-hour COP

Best variables to use to capture hour-by-hour COP I am trying to capture the instantaneous COP of various HVAC system up

2019-10-24 16:44:59 -0500 commented answer Determining the heating load that's independent of upgrade choice

How would I compare electric baseboard heat with the propane furnace upgrade? Wouldn't I just run into the same problems

2019-10-24 16:44:26 -0500 commented answer Determining the heating load that's independent of upgrade choice

How would I compare electric baseboard heat with the propane furnace upgrade? Wouldn't I just run into the same problems

2019-10-23 15:24:48 -0500 commented answer Determining the heating load that's independent of upgrade choice

Thank you for your insight Eric. I tried comparing coil heat output variables, and there are still times when the values

2019-10-23 14:04:40 -0500 commented answer Determining the heating load that's independent of upgrade choice

Thank you for your insight Eric. I tried comparing coil heat output variables, and there are still times when the values

2019-10-22 20:19:58 -0500 commented answer Determining the heating load that's independent of upgrade choice

How would I simulate with IdealLoadsAirSystems using Parametric Analysis Tool + ResStock directory? There is no "IdealLo

2019-10-21 14:53:55 -0500 asked a question Determining the heating load that's independent of upgrade choice

Determining the heating load that's independent of upgrade choice I've been working with the project_singlefamilydetache

2019-10-16 11:32:48 -0500 received badge  Teacher (source)
2019-10-16 08:47:39 -0500 answered a question Difference between editing buildstock.csv versus location + location-region.tsv?

So, in experience so far, editing the buildstock.csv versus the locations.tsv and locations-region.tsv has no difference

2019-10-01 17:38:45 -0500 commented answer Apply Upgrade gets rid of Building Characteristics Report?

Thank you so much! The github solution worked!

2019-09-30 15:11:11 -0500 marked best answer Apply Upgrade gets rid of Building Characteristics Report?

Hello everyone,

I'm loading project_singlefamilydetached from ResStock into the Parametric Analysis Tool, and an issue I'm running into is that whenever I have an upgrade applied, my results.csv file does not produce ANY entries for the building_characteristics_report columns. Entries for simulation_output_report columns are produced fine, and I see my upgrade name filled out in the "simulation_output_report.upgrade_name" column, so I know my entry for Apply Upgrade is not being ignored.

However, when I choose to skip the Apply Upgrade measures, THEN my results.csv file produces entries for the building_characteristics_report columns. Is anyone else experiencing this issue? I really don't know what the problem is, since I have the "Building Characteristics Report" measure unchecked for both situations.

2019-09-30 15:11:11 -0500 received badge  Scholar (source)
2019-09-27 16:02:25 -0500 asked a question Apply Upgrade gets rid of Building Characteristics Report?

Apply Upgrade gets rid of Building Characteristics Report? Hello everyone, I'm loading project_singlefamilydetached fro

2019-09-22 10:23:56 -0500 received badge  Supporter (source)
2019-09-20 15:30:32 -0500 commented question Difference between editing buildstock.csv versus location + location-region.tsv?

Apologies, to clarify, when I say "anything I put in Apply Upgrade won't go through", I mean that my results.csv file do

2019-09-20 08:26:25 -0500 asked a question Difference between editing buildstock.csv versus location + location-region.tsv?

Difference between editing buildstock.csv versus location + location-region.tsv? Context: Using "project_singlefamilyd