First time here? Check out the Help page!
2023-06-01 23:09:49 -0500 | edited answer | Unmet Hours slack channel (chat) ~~My vote is for Gitter because the OS and EP development takes place nearby on GitHub and the majority of the questions |
2023-06-01 23:08:38 -0500 | commented answer | Unmet Hours slack channel (chat) @ianvg Slack and Discord are the current "active" ones. @julien marrec is the Slack Invite bot still working? |
2023-06-01 23:08:02 -0500 | commented answer | Unmet Hours slack channel (chat) @ianvg Slack and Discord are the current "active" ones. @julien marrec is the Slack Invite bot working still? |
2022-11-14 09:08:03 -0500 | edited answer | Get/Set default COP for district cooling via openstudio SDK (Rather than creating a new question I think it is better to continue here for future reference.) I managed to change t |
2022-11-13 12:54:49 -0500 | commented answer | Get/Set default COP for district cooling via openstudio SDK @mortar io great, report back with your results. |
2022-11-13 11:02:36 -0500 | edited answer | Get/Set default COP for district cooling via openstudio SDK No, the DistrictCooling (and DistrictHeating) objects don't have fields for efficiency, so you could post-process the en |
2022-11-13 11:01:11 -0500 | commented answer | Get/Set default COP for district cooling via openstudio SDK Yeah Michael Witte mentioned that in the issue I linked above, which I haven't used. Reading the docs it appears that it |
2022-11-12 20:54:53 -0500 | received badge | ● Rapid Responder (source) |
2022-11-12 20:54:53 -0500 | answered a question | Get/Set default COP for district cooling via openstudio SDK No, the DistrictCooling (and DistrictHeating) objects don't have fields for efficiency, so you could post-process the en |
2022-11-12 20:50:06 -0500 | received badge | ● Rapid Responder (source) |
2022-11-12 20:50:06 -0500 | answered a question | IGDB historical versions, data access What have you tried? Have you read through the website? Looks like the IGDB are Microsoft Data Base files that can be op |
2022-10-14 14:03:08 -0500 | commented answer | What's the COP/EER of Ideal Loads Air System @liza lee it is saying that by generalizing the efficiency of heating and cooling systems. A COP of 3.0 is basically an |
2022-10-14 13:50:10 -0500 | commented answer | What's the COP/EER of Ideal Loads Air System @Liza Lee it's mentioned here. https://bigladdersoftware.com/epx/docs/22-2/input-output-reference/group-zone-forced-air- |
2022-10-14 13:41:58 -0500 | commented answer | What's the COP/EER of Ideal Loads Air System @Liza Lee it is here. https://bigladdersoftware.com/epx/docs/22-2/input-output-reference/group-zone-forced-air-units.htm |
2022-10-14 13:41:44 -0500 | commented answer | What's the COP/EER of Ideal Loads Air System @Liza Lee - it is here. https://bigladdersoftware.com/epx/docs/22-2/input-output-reference/group-zone-forced-air-units.h |
2022-10-14 13:41:11 -0500 | commented answer | What's the COP/EER of Ideal Loads Air System @Liza Lee - it is. This component can be thought of as an ideal unit that mixes air at the zone exhaust condition (o |
2022-10-14 11:34:15 -0500 | commented answer | What's the COP/EER of Ideal Loads Air System Here's a relevant feature request to add efficiency fields to the District* objects. https://github.com/NREL/EnergyPlus/ |
2022-08-05 10:37:59 -0500 | commented answer | LEED Reports in OpenStudio @JasonGlazer see above. @furtonb most likely it hasn't been added to the new version of the BCL. https://bcl.nrel.gov/co |
2022-08-05 10:36:24 -0500 | commented answer | LEED Reports in OpenStudio @JasonGlazer see above. |
2022-07-14 10:22:26 -0500 | edited answer | IECC standard reference HVAC system for VRF/DOAS Hotels >3 stories fall under Group R occupancy per the IBC. So, you could model the baseline as a System 8 (PTHP). I |
2022-07-14 10:21:18 -0500 | edited answer | IECC standard reference HVAC system for VRF/DOAS Hotels >3 stories fall under Group R occupancy per the IBC. So, you could model the baseline as a System 8. IECC-20 |
2022-07-13 11:40:49 -0500 | edited answer | IECC standard reference HVAC system for VRF/DOAS I believe hotels are considered "residential", at least according to 90.1 (check the IECC definitions, I don't have a co |
2022-07-13 11:38:36 -0500 | edited answer | IECC standard reference HVAC system for VRF/DOAS I believe hotels are considered "residential", at least according to 90.1 (check the IECC definitions, I don't have a co |
2022-07-13 11:37:45 -0500 | edited answer | IECC standard reference HVAC system for VRF/DOAS I believe hotels are considered "residential", at least according to 90.1 (check the IECC definitions, I don't have a co |
2022-07-13 11:36:00 -0500 | edited answer | IECC standard reference HVAC system for VRF/DOAS I believe hotels are considered "residential", at least according to 90.1 (check the IECC definitions, I don't have a co |
2022-07-13 11:34:58 -0500 | received badge | ● Rapid Responder (source) |
2022-07-13 11:34:58 -0500 | answered a question | IECC standard reference HVAC system for VRF/DOAS I believe hotels are considered "residential" (check the IECC definitions), at least according to 90.1 (I don't have a c |
2022-06-01 09:51:43 -0500 | commented answer | Merge select gbXML file elements Also worth noting that there are XML extensions for VS Code. |
2022-05-25 13:19:50 -0500 | commented answer | Size report units kBtu/h should be MBH @TheEnergyTutor coming to a Q&A site asking for help and then insulting someone who tries to help is not a good way |
2022-05-12 16:36:48 -0500 | edited answer | How to simulate PCM materials in Openstudio / Energyplus? I wrote a simple measure called Envelope Material Property Phase Change that could be useful. My results did not show si |
2022-05-12 16:33:59 -0500 | edited answer | How to simulate PCM materials in Openstudio / Energyplus? I wrote a simple measure called Envelope Material Property Phase Change that could be useful. Note, I did not see signif |
2022-05-12 16:29:46 -0500 | answered a question | How to simulate PCM materials in Openstudio / Energyplus? I wrote a simple measure called Envelope Material Property Phase Change that could be useful. Note, I did not see signif |
2022-05-12 16:29:46 -0500 | received badge | ● Rapid Responder (source) |
2022-05-12 16:16:59 -0500 | commented answer | baseboard btu per hour sizing @theenergytutor it's helpful to describe what you've already tried (like reading all the EP documentation) per the Help |
2022-05-10 08:56:54 -0500 | commented answer | OpenStudio SDK Connect Coil to PlantLoop Julien's to_actual_object method is also helpful to avoid all the casting that is required without it. https://unmethour |
2022-05-10 08:56:16 -0500 | commented answer | OpenStudio SDK Connect Coil to PlantLoop In Ruby, there's the object.class method, which will return the entire class i.e. OpenStudio::Model::CoilHeatingWater. I |
2022-05-10 08:55:41 -0500 | commented answer | OpenStudio SDK Connect Coil to PlantLoop In Ruby, there's the object.class method, which will return the _entire_ class i.e. OpenStudio::Model::CoilHeatingWater. |
2022-05-10 08:55:14 -0500 | commented answer | OpenStudio SDK Connect Coil to PlantLoop In Ruby, there's the object.class method, which will return the _entire_ class i.e. OpenStudio::Model::CoilHeatingWater. |
2022-05-10 08:54:53 -0500 | commented answer | OpenStudio SDK Connect Coil to PlantLoop In Ruby, there's the object.class method, which will return the _entire_ class i.e. OpenStudio::Model::CoilHeatingWater. |
2022-05-09 16:30:45 -0500 | commented answer | OpenStudio SDK Connect Coil to PlantLoop You could also use plant_loop_object.sizingPlant.loopType == 'Heating' to make your script more generic rather than rely |
2022-05-09 16:30:07 -0500 | commented answer | OpenStudio SDK Connect Coil to PlantLoop You could also use plant_loop_object.sizingPlant.loopType == 'Heating' to make your script more generic rather than rely |
2022-05-04 12:59:01 -0500 | commented question | Size report units kBtu/h should be MBH And what about kBtu/ft2? It's the standard unit for EUI mixing an SI prefix with an IP unit. |
2022-05-04 12:58:27 -0500 | commented question | Size report units kBtu/h should be MBH And what about kBtu/ft2? It's the standard unit for EUI mixing SI and IP units. |
2022-05-04 12:52:32 -0500 | commented question | Size report units kBtu/h should be MBH And what about kBtu/ft2? |
2022-04-21 16:06:17 -0500 | edited answer | Fan Power Inputs in OpenStudio IDL-Boise has created this spreadsheet tool that will calculate fan power given a few input parameters. It will aid you |
2022-02-18 17:08:25 -0500 | commented answer | OpenStudio Only Displays 1 Zone of 3 Zone Model Cory, feel free to accept [check] your own answer for the karma points. |
2022-01-21 14:02:32 -0500 | commented question | Interoperability of Autodesk Revit with OpenStudio packages If it's important to you, Revit has, as of v2022, used an older version of OpenStudio (2.8.0). |
2022-01-21 13:59:08 -0500 | commented answer | high electricity use for chiller When this happened or I was unable to get detailed performance data, I would often simply use ChillerConstantCOP (not wr |
2022-01-13 09:12:04 -0500 | commented question | Modeling Displacement Ventilation in OpenStudio or EnergyPlus, High Energy Consumption @yi it doesn't appear to be on the new BCL site https://bcl.nrel.gov/, but it's still in a private GitHub repo. Maybe @d |
2022-01-13 09:11:27 -0500 | commented question | Modeling Displacement Ventilation in OpenStudio or EnergyPlus, High Energy Consumption @yi it doesn't appear to be on the new BCL site https://bcl.nrel.gov/, but it's still in a private GitHub repo. Maybe @D |