Question-and-Answer Resource for the Building Energy Modeling Community
Get started with the Help page
Ask Your Question

liu shuo's profile - activity

2019-08-29 19:55:46 -0500 commented answer Problem about Radiant Cooling system that doesn't have Cooling rate and Mass flow

Thank you very much. I've sent my .idf file to your e-mail. I'm sorry to have taken up your time. Looking forward your r

2019-08-28 00:59:09 -0500 commented answer Problem about Radiant Cooling system that doesn't have Cooling rate and Mass flow

Yeah, my case is almost the same setup as this example idf. So I'm confused. If possible,can I know your e-mail? I want

2019-08-27 23:45:36 -0500 commented answer Problem about Radiant Cooling system that doesn't have Cooling rate and Mass flow

I had built only a Radiant system for this building(without Air loop case) . But the same problem occurred. There was no

2019-08-27 19:18:17 -0500 commented answer Problem about Radiant Cooling system that doesn't have Cooling rate and Mass flow

Thank you for your answer. I'm sure that the radiant system has its own temperature and humidity control thermostat. And

2019-08-27 19:18:11 -0500 commented answer Problem about Radiant Cooling system that doesn't have Cooling rate and Mass flow

Thank you for your answer. I'm sure that the radiant system has its own temperature and humidity control thermostat. And

2019-08-27 19:17:18 -0500 commented answer Problem about Radiant Cooling system that doesn't have Cooling rate and Mass flow

Thank you for your answer. I'm sure that the radiant system has its own temperature and humidity control thermostat. And

2019-08-21 21:44:41 -0500 edited question Problem about Radiant Cooling system that doesn't have Cooling rate and Mass flow

Problem about Radiant Cooling system that doesn't have Cooling rate and Mass flow I made a system with low temperature r

2019-08-21 21:44:41 -0500 received badge  Editor (source)
2019-08-21 21:43:13 -0500 edited question Problem about Radiant Cooling system that doesn't have Cooling rate and Mass flow

Problem about Radiant Cooling system that doesn't have Cooling rate and Mass flow I made a system with low temperature r

2019-08-21 21:36:21 -0500 asked a question Problem about Radiant Cooling system that doesn't have Cooling rate and Mass flow

Problem about Radiant Cooling system that doesn't have Cooling rate and Mass flow I made a system with low temperature r

2019-07-15 06:24:22 -0500 asked a question Is there a Cooling coil or air conditioner that condesation heat can be used as the regeneration heat of desiccant?

Is there a Cooling coil or air conditioner that condesation heat can be used as the regeneration heat of desiccant? Is t

2019-07-06 09:08:11 -0500 received badge  Student (source)
2019-07-05 09:21:04 -0500 asked a question Low temperature radiant floor with heating and cooling only have cooling rate during a year

[Energyplus]Low radiant floor with heating and cooling_Q: only have cooling rate during a year(no heating rate) I made a