matbla's profile - activity

2023-06-08 17:52:30 -0500 received badge  Rapid Responder (source)
2023-06-08 17:52:30 -0500 answered a question Design Builder Air to Air Heat Pump important question

Answer could be in this post here?

2023-05-29 22:04:56 -0500 received badge  Rapid Responder (source)
2023-05-29 22:04:56 -0500 answered a question Run EnergyPlus continuously

Hi there, I dont think much influence, considering 1 day is <1% of the year. Perhaps think of it like a TMY file, w

2023-05-23 00:11:04 -0500 marked best answer Creating a MVHR system for residential application

Hi there,

I have a residential project that has mechanical ventilation with heat recovery. I am using designbuilder detailed HVAC to model this system, and am aiming to provide summer bypass function (economiser).

System design: Typical residential MVHR system with supply and extract fan inside the MVHR unit, including summer boost bypass of heat recovery. The design controls for summer bypass based on a thermostat installed in living room. When summer bypass is in operation, the other two supply zones (2 bedrooms) recieve boost air, as dependent on the demand for boosts at living room thermostat.

The control logic is summer boost bypass ON

IF Troom > 22C, AND Troom > TOA, AND TOA > 12C

TOA = Temp outside air

Troom = Temperature living room thermostat

System in designbuilder: I have modelled the system as a VAV central AHU with VAV No Reheat air distribution units serving three zones (living/kitchen and 2 bedrooms). Reciculation is used to enable use of the economiser which emulates the boost summer bypass. The AHU OA fraction is set to always 1.0, to prevent any recirculation and provide 100% fresh air. I have put a setpoint manager on supply side inlet (after AHU), controlling for 'single zone cooling', with living room as selected zone for cooling control.

The problem: I have been successful creating the above control logic. However, the problem I have is that the zone airflows under boost mode are independent based on each zone's unique thermostat, rather than based on just the living room thermostat. Instead, I would like each zone's airflow to boost dependent on the living room thermostat. Each zone airflow should follow the same varying profile albeit different airflow based on each zone max airflow rate. But even with single zone cooling setpoint manager, and living room selected, the zones still vary their airflow independently.

One thing I have tried was to edit the idf text creating a single thermostat, and applying a ZoneList of all three zones to the one thermostat object. However, this didnt change the result. Each zone airflow was still modulating independent.

Has anyone created a similar system before, and does anyone know how each zone airflow can be dependent on a single thermostat control?

I have uploaded the system idf here

Thanks,

2023-05-23 00:11:04 -0500 received badge  Scholar (source)
2023-05-23 00:10:47 -0500 answered a question Creating a MVHR system for residential application

This query is now solved using a custom EMS program. The HVAC system used was a VAV central AHU, combined with CAV no re

2023-05-16 04:51:20 -0500 commented question Creating a MVHR system for residential application

Hi Greg, thanks for your response. The designed system does not have VAV terminal boxes. Without yet having EMS scriptin

2023-05-16 04:48:28 -0500 commented question Creating a MVHR system for residential application

Hi Keigo, thanks for your response - I will add a schematic in the coming days.

2023-05-14 15:19:14 -0500 commented answer Dilemma combining AirflowNetwork with a zone plenum in EnergyPlus IDF?

Interesting, what is your application of AFN that needs a return plenum?

2023-05-13 22:44:35 -0500 edited answer Long waiting time when openning eso file in Designbuilder Result Viewer

I have experienced the same, usually when hourly or sub-hourly results are selected for the simulation. At hourly, with

2023-05-13 22:35:41 -0500 edited question Creating a MVHR system for residential application

Creating a MVHR system for residential application Hi there, I have a residential project that has mechanical ventilati

2023-05-13 22:35:17 -0500 received badge  Editor (source)
2023-05-13 22:35:17 -0500 edited question Creating a MVHR system for residential application

Creating a MVHR system for residential application Hi there, I have a residential project that has mechanical ventilati

2023-05-13 22:27:53 -0500 answered a question Dilemma combining AirflowNetwork with a zone plenum in EnergyPlus IDF?

Hi Bhonz, I have a 'work in progress' residential MVHR system which includes a return plenum. The system was created in

2023-05-12 12:35:16 -0500 received badge  Teacher (source)
2023-05-10 16:33:08 -0500 answered a question Long waiting time when openning eso file in Designbuilder Result Viewer

I have experienced the same, usually when hourly or sub-hourly results are selected for the simulation. At hourly, with

2023-05-10 16:33:08 -0500 received badge  Rapid Responder (source)
2023-05-09 16:54:09 -0500 answered a question designbuilder v7 simple hvac seasonal cop has no effect

The data tab on the right is only part of the help function. It displays the inputs associated with whichever simple HVA

2023-05-08 09:45:18 -0500 received badge  Student (source)
2023-05-08 09:41:35 -0500 asked a question Creating a MVHR system for residential application

Creating a MVHR system for residential application Hi there, I have a residential project that has mechanical ventilati