2021-05-09 08:54:59 -0500 | marked best answer | what is best way to model parking garage May I know what is the best way to model underground parking garage which has opening to outdoor? |
2021-04-27 04:59:42 -0500 | commented question | Control of Ice Storage model with Heat Exchanger hi @Keigo could you please leave a mail? |
2021-04-21 00:40:59 -0500 | commented question | Control of Ice Storage model with Heat Exchanger hi @keigo, you may add common pipe to ice storage loop to operate the ice storage system |
2020-08-20 20:50:32 -0500 | commented question | what is best way to model parking garage @MatthewSteen I am trying to analyze energy consumption of a mall which has underground parking garage below it. As the |
2020-08-10 22:23:32 -0500 | marked best answer | Unhandled exception with Openstudio application v1.0.1 Using openstudio application v1.0.1. |
2020-08-10 22:23:31 -0500 | commented answer | Unhandled exception with Openstudio application v1.0.1 Many thanks, it solved! |
2020-08-10 22:12:38 -0500 | asked a question | Unhandled exception with Openstudio application v1.0.1 Unhandled exception with Openstudio application v1.0.1 Using openstudio application v1.0.1. An unhandled exception error |
2020-08-06 05:25:47 -0500 | commented question | An unhandled exception has occurred. boost::filesystem::create_directory: Access is denied Hi, I have same issue with Openstudio 1.0.0.1. Did you solve it already? |
2020-08-06 00:07:14 -0500 | received badge | ● Organizer (source) |
2020-08-05 23:55:07 -0500 | asked a question | Is it possible to reheat the air with heat recovery system? Is it possible to reheat the air with heat recovery system? As below diagram shows, heat recovery system is exchanging t |
2020-08-02 20:51:57 -0500 | commented question | what is best way to model parking garage @Aaron Boranian, many thanks for your reply! |
2020-07-30 20:32:17 -0500 | commented question | what is best way to model parking garage @Aaron Boranian, Thanks for your comment. Both posts all recommend including underground parking garage in the energy mo |
2020-07-28 00:09:41 -0500 | edited question | what is best way to model parking garage best way to model parking garage May I know what is the best way to model underground parking garage which has opening t |
2020-07-27 21:35:58 -0500 | asked a question | what is best way to model parking garage best way to model parking garage May I know what is the best way to model underground parking garage which has opening t |
2020-07-04 04:33:12 -0500 | received badge | ● Enthusiast |
2020-06-23 10:22:59 -0500 | commented answer | Cooling Supply with dual compressor chiller and ice thermal storage Thanks for your reply! I am now trying to use same method to build the plant loop. Does the ice storage need to be model |
2020-06-20 12:24:12 -0500 | received badge | ● Commentator |
2020-06-20 12:24:12 -0500 | commented answer | Flow rate of Fluid-to-Fluid Heat exchanger The reason is I am now modelling two cooling plants which serve chilled water for one building based on different time. |
2020-06-19 22:09:33 -0500 | commented answer | EMS control timestep Hi, @Aaron Boranian many thanks for your explanation. Then, if I want to transfer exactly same condition (flow rate and |
2020-06-19 22:04:35 -0500 | marked best answer | EMS control timestep Dear Users, What I am expect is the pump flow will be identical with the flow rate of load profile during every timestep, but the result shows that it will be excuted after one time-step. (For example, the timestep is 6, and load profile flow rate is 6 for one hour, then result of pump's flow rate for same hour is calculated as 5, remaining 1 is counted in next hour.) |
2020-06-19 22:04:35 -0500 | received badge | ● Scholar (source) |
2020-06-19 11:29:14 -0500 | edited question | EMS control timestep EMS control timestep Dear Users, How to provide same time-step sensor value to actuator for plant system? I have made a |
2020-06-19 11:26:13 -0500 | asked a question | EMS control timestep EMS control timestep Dear Users, How to provide same time-step sensor value to actuator for plant system? I have made a |
2020-06-17 22:38:01 -0500 | commented answer | Modeling Primary-Secondary Chilled Water Pumps in OpenStudio Hi, @aparker the mentioned example file (energyplus v9.2) results that heat exchanger supply side outlet temp is much hi |
2020-06-17 21:58:35 -0500 | answered a question | Modeling primary-secondary plant loop with VSD pumps on both sides I have similar issue here. To simulate a complex cooling plant, I have to use heat exchanger to transfer fluid from one |
2020-06-15 23:00:53 -0500 | commented question | Flow rate of Fluid-to-Fluid Heat exchanger @mehrdad According to engineering reference, district cooling may follow the given flow rate. So, I think the issue here |
2020-06-15 22:58:52 -0500 | commented question | Flow rate of Fluid-to-Fluid Heat exchanger @mehrdad According to engineering reference, district cooling may follow the given flow rate. So, I think the issue here |
2020-06-15 20:30:34 -0500 | commented question | Flow rate of Fluid-to-Fluid Heat exchanger @mehrdad Here is the link for the idf file. ( https://we.tl/t-p2ALSAZ6nZ ) Very appreciate for your help! |
2020-06-15 17:58:31 -0500 | commented question | Flow rate of Fluid-to-Fluid Heat exchanger @mehrdad Yes, heat exchanger’s supply side flow rate is identical with the load profile flow rate. But the demand side’s |
2020-06-15 09:23:07 -0500 | asked a question | Flow rate of Fluid-to-Fluid Heat exchanger Flow rate of Fluid-to-Fluid Heat exchanger I have modeled primary/secondary loop with fluid-to-fluid heat exchanger acco |
2020-06-12 01:45:59 -0500 | asked a question | How to set the plant fluid chilled by ice storage only? How to set the plant fluid chilled by ice storage only? Ice storage and one set of chillers are connected in series. Dur |
2020-06-10 13:10:40 -0500 | commented answer | How to stop chiller from running while thermal energy storage still has capacity? @mldichter Actually, the chiller and ice storage in my model is connect with heat exchanger, but as long as the chiller |
2020-06-10 10:37:57 -0500 | commented answer | How to stop chiller from running while thermal energy storage still has capacity? Hi, @mldichter, did you find the way to solve this problem? I am now trying to model a series chiller and ice storage lo |
2020-06-09 20:51:43 -0500 | edited question | Cooling Supply with dual compressor chiller and ice thermal storage Cooling Supply with dual compressor chiller and ice thermal storage I am now trying to modeling a cooling plant which se |
2020-06-09 20:51:43 -0500 | received badge | ● Editor (source) |
2020-06-09 20:45:11 -0500 | edited question | Cooling Supply with dual compressor chiller and ice thermal storage Cooling Supply with dual compressor chiller and ice thermal storage I am now trying to modeling a cooling plant which se |
2020-06-09 20:43:45 -0500 | commented answer | Using more than one splitter-mixer pair in one Plant Loop @Aaron Boranian yes, they are same question |
2020-06-09 10:31:49 -0500 | received badge | ● Student (source) |
2020-06-09 10:28:05 -0500 | asked a question | Cooling Supply with dual compressor chiller and ice thermal storage Cooling Supply with dual compressor chiller and ice thermal storage I am now trying to modeling a cooling plant which se |
2020-06-09 10:27:58 -0500 | commented answer | Using more than one splitter-mixer pair in one Plant Loop Dear @Aaron Boranian, I have a query regarding to the FFHX issue. As I know that energyplus loop needs at least one pump |
2020-06-09 03:46:34 -0500 | received badge | ● Supporter (source) |