2022-09-12 13:45:29 -0500 | marked best answer | Maximum capacity of Coil:Cooling:DX:SingleSpeed HI, I am working on a LEED energy model for a data center. The design case model ran through fine but my baseline model crashes with the following error: The IT and electrical rooms have very high internal loads as it is a datacenter. These spaces are conditioned by system 4 - PTHP with single speed DX cooling, single speed DX Heating coils and constant flow fan. Based on my sizing calculations, the rated air flow per watt for the zones is 0.000075 m³/s per watt. According to the idd file, I see that this value should be between 0.00004027 m3/s and .00006041 m3/s per watt of rated total cooling capacity. Here is the error that I get: Is there a work around to get this Coil:Cooling:DX:SIngleSpeed component used with ZoneHVAC:PackagedTerminalHeatPump to work? Thank you, Raghu |
2019-05-15 12:00:41 -0500 | commented answer | Modeling heated floor with hot water from condenser side of water cooled VRF Thanks for looking into it @Matt Doiron , my confusion is about setting up the condenser side loop. According to the pre |
2019-05-14 16:30:08 -0500 | asked a question | Modeling heated floor with hot water from condenser side of water cooled VRF Modeling heated floor with hot water from condenser side of water cooled VRF Hi, A similar question was asked previousl |
2019-05-01 13:20:02 -0500 | commented answer | VRF with hot water generation, heat exchanger @aaron boranian - I ran into the same situation and I am not 100% clear about the set up of the plant loop suggested in |
2018-08-07 12:16:32 -0500 | marked best answer | How to delete OS:ThermostatSetpoint:DualSetpoint objects? Hi, I am working with OS v 1.7.0. I created my complete model and realized that some of my thermal zones did not need thermostats. I could delete the thermostat schedules using the OpenStudio GUI but my model was crashing as I could not delete the OS:ThermostatSetpoint:DualSetpoint objects that were created. Is there a way that I can delete these objects through the GUI? I tried deleting these objects after opening the OSM file in a text editor but read in the below post that it may not be a great idea. https://unmethours.com/question/4189/... Is there a better way to delete thermostats from themal zones in OpenStudio? Thank you, Raghu |
2018-05-15 13:36:41 -0500 | commented question | can't split surface Based on your description, your question seems to be similar to this issue. Please take a look and see if the solution h |
2018-04-25 12:10:42 -0500 | commented answer | Proposed model constructions, leed That is my interpretation as well. |
2018-04-24 14:01:57 -0500 | answered a question | Proposed model constructions, leed For projects where we do not receive all construction layers, I usually try get information about the different layer ma |
2018-04-13 12:18:35 -0500 | marked best answer | CBECC-com inputs mapping to E+ inputs Was wondering if someone here know of a good resource that documents the mapping of CBECC-com inputs to corresponding EnergyPlus components that are populated in the back-end? Any suggestions would be super helpful! Thanks! |
2018-04-13 12:05:38 -0500 | commented answer | CBECC-com inputs mapping to E+ inputs @pflaumingo - That answers my question that there is not specific document that has this info. I didn't look at the reve |
2018-04-13 11:45:43 -0500 | commented question | CBECC-com inputs mapping to E+ inputs @mdahlhausen Thanks! I looked at this and it was helpful to understand SDD schema. I was looking for translation logic i |
2018-04-04 18:38:18 -0500 | commented question | CBECC-com inputs mapping to E+ inputs @mdahlhausen the link doesn't seem to work. Can you re-share it? To elaborate, I am having a tough time doing QA for my |
2018-04-04 17:26:46 -0500 | asked a question | CBECC-com inputs mapping to E+ inputs CBECC-com inputs mapping to E+ inputs Was wondering if someone here know of a good resource that documents the mapping o |
2018-03-23 14:33:53 -0500 | commented question | GBXML OR XML CUSTOM EXPORT You can create a simple tool to the update the gbXML from openstudio to the format that you desire. You can use any scri |
2018-03-23 14:23:16 -0500 | answered a question | Do you actually check this when modelling for LEED? Ashrae 90.1-2007 - G3.1.1 Exception b. To answer your question - I had some projects in the past that had several zones (over 100+) that fit these exception. I |
2018-02-28 18:50:10 -0500 | commented question | High cooling load Also, which cooling coil is shown in the plot? (Just to make sure that we are looking at the terminal cooling coil for t |
2018-02-28 13:41:33 -0500 | commented question | High cooling load Did you check all the other loads for the space - Lighting, occupancy (if any), infiltration (if any), outside air suppl |
2018-02-28 13:05:39 -0500 | received badge | ● Civic Duty (source) |
2017-12-21 13:43:30 -0500 | commented question | OpenStudio/ SketchUp - Euclid for Exporting gbxml files from DOE Prototype Models @nu energy , Openstudio should be able to export a gbXML file. If you are running into the strictness level 'Draft', can |
2017-12-15 15:42:22 -0500 | commented answer | Editing Cbecc-Com XML input with Python? Sikuli seems to be an interesting tool! Thanks for sharing. Will try to explore it. |
2017-12-15 12:01:24 -0500 | edited answer | Editing Cbecc-Com XML input with Python? I simply use excel to go through the input XML file and populate/repopulate fields based on project specific values. Sin |
2017-12-14 12:24:58 -0500 | answered a question | Editing Cbecc-Com XML input with Python? I simply use excel to go through the input XML file and populate/repopulate fields based on project specific values. Sin |
2017-11-16 11:26:32 -0500 | commented question | Openstudio 2.3 won't launch Can you check if the issues reported in these questions solves your issue? https://unmethours.com/question/13399/openst |
2017-10-27 17:09:52 -0500 | commented answer | Energyplus: is it possible to increase the variability of power demanded for a chilled water plant? Glad that was a good start. It is a tough problem to make sure that the energy model consumption exactly matches the act |
2017-10-26 05:32:21 -0500 | answered a question | Energyplus: is it possible to increase the variability of power demanded for a chilled water plant? I am assuming that the X-axis for the graph is time. If so, based on the graph - it appears that the real-life system ha |
2017-10-23 01:26:30 -0500 | answered a question | Branch Errors in Simulation What EnergyPlus version is the IDF in? and what version of EP-launch are you using? The Branch objects in older versions |
2017-10-02 09:32:51 -0500 | received badge | ● Critic (source) |
2017-09-21 10:35:32 -0500 | commented question | Using a (thick) surface as thermal storage in E+ So you mean, the slab doesn't necessarily have a flow through it during the night but holds the hot/cold water to be dis |
2017-09-21 07:18:24 -0500 | commented question | Using a (thick) surface as thermal storage in E+ Are you looking to model the slab with some sort of thermal storage that is expected to delay the discharge of heat /coo |
2017-09-18 10:34:53 -0500 | commented answer | 90.1-2010 App. G - Self shading & adjacent bldgs The narrative for baseline envelope requirements does talk about modeling the exterior envelope components with "Equival |
2017-09-18 10:29:26 -0500 | commented answer | 90.1-2010 App. G - Self shading & adjacent bldgs That's right, The language is slightly confusing. I was also wondering about a donut shaped buildings. I do not see a wa |
2017-09-18 09:37:41 -0500 | answered a question | 90.1-2010 App. G - Self shading & adjacent bldgs The user's manual for ASHRAE 90.1-2010 clarifies the difference between self-shading and shading by other structures tha |
2017-09-12 10:22:04 -0500 | commented question | openstudio app not launching I had some issues working with Openstudio app. I was able to launch the app but could not open files in it. Are you usin |
2017-08-30 09:50:07 -0500 | commented answer | OpenStudio Crash in Windows 8.1 I spent the past couple of days wondering what I was doing wrong. My Dell laptop has Windows 10 and OpenStudio 1.5.0 was |
2017-08-29 09:50:07 -0500 | edited answer | How to specify Supply Air flow at VAV Once you run a model with HVACTemplate objects, it is a good idea to verify the inputs in the expidf to make sure that t |
2017-08-29 09:35:12 -0500 | commented answer | How to specify Supply Air flow at VAV As mentioned, the object System:Sizing cannot be used to hardsize the flowrates in the system. It is the actual componen |
2017-08-24 12:25:28 -0500 | answered a question | How can i model hot water loop and air loop for a single zone Hi @Hannes The situation in the question that you referenced does not apply to your building as you do not have two ai |
2017-08-23 12:14:09 -0500 | answered a question | How to specify Supply Air flow at VAV Hi @Anna Did you verify that the field System Availability Schedule Name, Supply Fan Maximum Flow Rate and Supply Fan M |
2017-08-16 15:49:46 -0500 | commented answer | Designbuilder/EnergyPlus Relief fan Could you explain the system that you are trying to model and how you intend to control it? |
2017-08-16 15:46:16 -0500 | commented answer | How to design an occupancy schedule based on Area/person method? what does the fract 0.0 or 0.05 or 0.2 mean? To be precise, that depends on your specific project requirements. Although, lighting schedules usually correspond to oc |
2017-08-16 14:45:27 -0500 | commented answer | How to design an occupancy schedule based on Area/person method? what does the fract 0.0 or 0.05 or 0.2 mean? I usually input input occupancy as number of people (reflecting peak occupancy). Technically it shouldn't matter how you |
2017-08-16 14:15:38 -0500 | answered a question | Designbuilder/EnergyPlus Relief fan Hi @kbk78 Not sure if you figured this out already. In EnergyPlus, the outdoor airflow is controlled using the object C |
2017-08-16 13:48:48 -0500 | commented answer | How do I avoid incorrect boundaries when using surface-matching and intersecting measures? Glad you were able to fix your issue! |
2017-08-16 13:46:59 -0500 | commented answer | How to design an occupancy schedule based on Area/person method? what does the fract 0.0 or 0.05 or 0.2 mean? @surajtalele That is correct. Although 9.5 people cannot occupy a space at a given time practically, this would account |
2017-08-16 13:18:36 -0500 | answered a question | How to design an occupancy schedule based on Area/person method? what does the fract 0.0 or 0.05 or 0.2 mean? Hi @surajtalele The occupancy schedule is based on the % of occupants that occupy a certain thermal zone at a given ti |
2017-08-15 16:26:06 -0500 | commented question | energyplus/ activity level table @surajtalele are you referring to the table with metabolic rates for various activities to be used in the "People" objec |
2017-08-14 10:39:49 -0500 | answered a question | Energy Plus demand end use components summary: District Heating vs Steam Hi @antonszilasi From the screenshot, it appears that the source of heating in your model is natural gas (and not steam |
2017-08-11 11:04:48 -0500 | answered a question | Surface error in energyplus & sketchup Hi @saravanan17 It looks like the following surfaces are adjacent and are matched B181FE (construction: INTERIOR WALL) |
2017-08-11 10:55:54 -0500 | answered a question | Node error how can i define it and rectify the error because the remaining zones are not showing any error.. Hi @saravanan17 It looks like you added a "ZoneControl:Thermostat" to the zone "7788C8" but did not assign any zone HVA |