2021-03-31 02:04:19 -0500 | commented question | VRF system electricity consumption increases when system gross rated cooling capacity increases As per my understanding zone sensible cooling load is constant then the electricity consumption also should have come co |
2021-03-30 23:10:24 -0500 | asked a question | VRF system electricity consumption increases when system gross rated cooling capacity increases VRF system electricity consumption increases when system gross rated cooling capacity increases Hi group, I am new to e |
2020-12-23 22:24:34 -0500 | marked best answer | Is the Chilled water cooling coil total load same as the chiller capacity? Hi group, I am new to EnergyPlus, is chiller capacity same as the chilled water cooling coil total load? Please clear my doubt. |
2020-12-19 03:53:10 -0500 | marked best answer | My chiller capacity is 133% higher than the OpenStudio design cooling load to meet the zone set point temperature. Why there is a big difference and Why the zone set point temperature is not met at the design cooling load? I am modelling a existing 12 storey office building. For validation purpose, I conditioned only 10th floor with actual cooling load and internal heat gains. I took water cooled chiller for my simulation. The OpenStudio design cooling load of 10th floor is 63 kW. My actual cooling load is 147 kW. I hard sized the chiller capacity as 147 kW, hence the zone set point temperature was met. If I take OpenStudio design cooling load of 63 kW as my chiller capacity, the zone setpoint temperature was not met. I assumed wall and window material properties with reasonable accuracy. Please clear my doubts. |
2020-12-19 03:52:01 -0500 | marked best answer | I used variable speed fan in my air loop for energy savings but the power consumption was not reduced. How to give correct coefficients for my model? Thanks in advance I used variable volume fan for single zone and the coefficients are C1=0.040759893999999998, c2=0.08804497, c3=-0.072926119999999997, c4=0.94373982300000003, c5=0, the fan pressure was 995 Pa and the flow rate was autosized. |
2020-12-19 03:52:01 -0500 | received badge | ● Scholar (source) |
2020-11-17 04:33:25 -0500 | asked a question | radiance measure running error radiance measure running error I am simulating a small model with radiance daylighting measure in Openstudio 2.7. While |
2020-11-10 04:06:19 -0500 | asked a question | Radiance measure failed to run Radiance measure failed to run Hi! I am a new user of Openstudio, I modelled radiance in a small room with illuminance m |
2020-09-10 07:46:38 -0500 | received badge | ● Supporter (source) |
2020-02-05 00:54:49 -0500 | commented answer | Is the Chilled water cooling coil total load same as the chiller capacity? Thank you Mr.Richard Raustad for clearing my doubt. |
2020-02-03 23:05:03 -0500 | asked a question | Is the Chilled water cooling coil total load same as the chiller capacity? Is the Chilled water cooling coil total load same as the chiller capacity? Hi group, I am new to EnergyPlus, is chiller |
2020-02-02 22:20:27 -0500 | commented answer | My chiller capacity is 133% higher than the OpenStudio design cooling load to meet the zone set point temperature. Why there is a big difference and Why the zone set point temperature is not met at the design cooling load? Thank you Mr. Andrew Parker for your kind reply. |
2020-01-29 06:12:00 -0500 | asked a question | My chiller capacity is 133% higher than the OpenStudio design cooling load to meet the zone set point temperature. Why there is a big difference and Why the zone set point temperature is not met at the design cooling load? My chiller capacity is 133% higher than the OpenStudio design cooling load to meet the zone set point temperature. Why t |
2019-11-18 05:18:20 -0500 | asked a question | What is the function of thermostat schedule that used in thermal zone? What is the function of thermostat schedule that used in thermal zone? Hi! I am simulating 9 storey hospital building a |
2019-11-13 01:52:03 -0500 | asked a question | What is the return air bypass set point temperature? What is the return air bypass set point temperature? I am doing energy modelling in a 9 storey building. In air loop sy |
2019-11-04 03:30:49 -0500 | asked a question | While running the base case measure for space it will generate this following error While running the base case measure for space it will generate this following error Hi, Please help me out from this fo |
2019-08-13 00:34:14 -0500 | commented question | What is the maximum ach(infiltration) for residential buildings? Thank you Sir, Actually I built 2 storey residential building, I calculate infiltration rate from Ashrae 1997 fundamenta |
2019-08-08 02:30:35 -0500 | asked a question | What is the maximum ach(infiltration) for residential buildings? What is the maximum ach(infiltration) for residential buildings? I would like to know the maximum infiltration rate in g |
2019-08-01 23:27:04 -0500 | commented question | Shall I modify the rated cooling capacity of the VRF Air conditioner to reduce the cooling unmet hours that download from the BCL? First I thank for your reply, I downloaded both 6 TR and 8 TR systems from BCL component. My building total cooling load |
2019-08-01 06:40:56 -0500 | asked a question | Shall I modify the rated cooling capacity of the VRF Air conditioner to reduce the cooling unmet hours that download from the BCL? Shall I modify the rated cooling capacity of the VRF Air conditioner to reduce the cooling unmet hours that download fro |
2019-07-14 12:39:39 -0500 | received badge | ● Student (source) |
2019-06-20 12:27:31 -0500 | commented answer | I used variable speed fan in my air loop for energy savings but the power consumption was not reduced. How to give correct coefficients for my model? Thanks in advance Hi Sir, I added VAV terminal box with the VAV fan. Now it works perfectly. Thank you once again for your valuable sugges |
2019-06-20 12:26:57 -0500 | commented answer | I used variable speed fan in my air loop for energy savings but the power consumption was not reduced. How to give correct coefficients for my model? Thanks in advance First I thank you for your reply. My HVAC system is a water cooled chilled system for a single floor commercial building |
2019-06-19 11:08:14 -0500 | asked a question | I used variable speed fan in my air loop for energy savings but the power consumption was not reduced. How to give correct coefficients for my model? Thanks in advance I used variable speed fan in my air loop for energy savings but the power consumption was not reduced. How to give corre |