2024-02-20 09:57:53 -0500 | commented question | Window internal surface temperature with having an internal roller shade Hi, Did you by any chance solve this? where can I find the interior temperature of the roller shades? Thanks |
2024-02-20 09:57:42 -0500 | commented question | Window internal surface temperature with having an internal roller shade Hi, Did you by any chance solved this? where can I find the interior temperature of the roller shades? Thanks |
2024-02-20 09:57:31 -0500 | commented question | Window internal surface temperature with having an internal roller shade Hi, Did you by any chance solve this? where can I find the interior temperature of the roller shades? Thanks |
2023-06-27 11:31:01 -0500 | asked a question | Cooling and heating system loads at building level Cooling and heating system loads at building level Hi, I would like to obtain the hourly values for heating and cooling |
2023-06-27 11:24:39 -0500 | asked a question | ASHRAE 55 Analytical comfort zone method calculation ASHRAE 55 Analytical comfort zone method calculation Hi there, I am currently carrying out the calculations required fo |
2023-05-23 10:43:29 -0500 | asked a question | ASHRAE 55 Analytical comfort zone method calculation ASHRAE 55 Analytical comfort zone method calculation Hi there, I am currently carrying out the calculations required fo |
2023-05-22 11:04:05 -0500 | commented question | How do you prove Thermal Comfort compliance via Energy Modeling? Hi there, I wonder the same. It is not evident anywhere in the standard if this requirement should be met for every sing |
2023-04-17 06:34:25 -0500 | commented answer | ASHRAE 90.1 2010 Baseline systems for a mall building I wonder. There will be several retail units for tenants (HVAC system is out of the landlord scope) where the baseline s |
2023-04-17 06:34:25 -0500 | received badge | ● Commentator |
2023-04-17 04:47:22 -0500 | commented answer | ASHRAE 90.1 2010 Baseline systems for a mall building Thank you! That is very clear. |
2023-04-17 02:46:54 -0500 | commented answer | ASHRAE 90.1 2010 Baseline systems for a mall building In oder to determine the power of the HVAC system. Should I consider the total of all the spaces? or I create one single |
2023-04-16 06:53:15 -0500 | marked best answer | ASHRAE 90.1 2010 Baseline systems for a mall building Hi there, I am currently working on an energy model for Mall building with tenants for a LEED CS certification compliance. I am struggling to figure out what Is the best method or process to assign the baseline systems to my thermal zones. In the mall there are quite a bit of different activities: cinema (>4000m2), F&B (kitchens), anchor fashion (>2500m2), >150 retail units (100-400m2 each), mall concourse(>19000m2), spa, fitness center, leisure, offices, server rooms, department store (>7000m2), supermarket, among others. According to ASHRAE 90.1 2010 following the section G3.1.1 Baseline HVAC System Type and Description I assume the following: -Retail units + supermarket -> System 7 (one single centralized HVAC unit with several zones?) or System 3 (one HVAC system per thermal block?) -Department store -> System 5 (one HVAC system per floor, the department store has 2 levels, 2 HVAC system 5 in total?) -Cinema -> System 5 (one HVAC system per floor, the cinema has 2 levels, 2 HVAC system 5 in total?) -Mall concourse -> System 7 (one HVAC system per floor, the mall concourse has 3 levels, 3 HVAC system 7 in total?) -Server rooms -> System 3 (one HVAC system per thermal block) -Anchor fashion -> System 3 -F&B (Kitchen) -> System 5 or 7 (one HVAC system per kitchen?) Are my assumptions correct? This is quite confusing, on the other hand ASHRAE 90.1 2010 G3.1.1 proposed to group floors with identical thermal blocks, does this mean that for the system 5 and 7 above I only need one single system and I can group the zones, this contradicts with the previous "For systems 5,6,7,8,9 and 10 each floor shall be modeled with a separate HVAC system. Could you provide me some feedback regarding this issue? Have you faced a similar case before, how did you address it? Thanks |
2023-04-16 05:48:00 -0500 | edited question | ASHRAE 90.1 2010 Baseline systems for a mall building ASHRAE 90.1 2010 Baseline systems for a mall building Hi there, I am currently working on an energy model for Mall buil |
2023-04-16 05:46:20 -0500 | commented answer | ASHRAE 90.1 2010 Baseline systems for a mall building I see. However, and due to the different type of activities according to ASHRAE 90.1 2010 G3.1.1 Additional system type |
2023-04-16 05:46:03 -0500 | commented answer | ASHRAE 90.1 2010 Baseline systems for a mall building I see. However, and due to the different type of activities according to ASHRAE 90.1 2010 G3.1.1 Additional system type |
2023-04-16 05:45:23 -0500 | edited question | ASHRAE 90.1 2010 Baseline systems for a mall building ASHRAE 90.1 2010 Baseline systems for a mall building Hi there, I am currently working on an energy model for Mall buil |
2023-04-16 05:44:59 -0500 | commented answer | ASHRAE 90.1 2010 Baseline systems for a mall building I see. However, and due to the different type of activities according to ASHRAE 90.1 2010 G3.1.1 Additional system type |
2023-04-16 05:44:47 -0500 | commented answer | ASHRAE 90.1 2010 Baseline systems for a mall building I see. However, and due to the different type of activities according to ASHRAE 90.1 2010 G3.1.1 Additional system types |
2023-04-14 10:41:08 -0500 | edited question | ASHRAE 90.1 2010 Baseline systems for a mall building ASHRAE 90.1 2010 Baseline systems for a mall building Hi there, I am currently working on an energy model for Mall buil |
2023-04-14 10:40:36 -0500 | asked a question | ASHRAE 90.1 2010 Baseline systems for a mall building ASHRAE 90.1 2010 Baseline systems for a mall building Hi there, I am currently working on an energy model for Mall buil |
2023-03-23 06:18:18 -0500 | asked a question | Spa and fitness centre loads Spa and fitness centre loads Hi there, I am carrying out an energy model for a mall building for LEED CS compliance. Wi |
2023-03-17 10:08:49 -0500 | commented question | Mall entrance infiltration modeling for LEED compliance Hi Aaron. Certainly. Close the other post, please. Thanks. |
2023-03-17 10:07:53 -0500 | marked best answer | Mall entrance infiltration modeling for LEED compliance Hi there, I am currently carrying out an energy modeling for a shopping mall. There are several entrances with vestibules. I was wondering if it would be required to account for the infiltration through the entrances, since it will have a high traffic. Have any of you faced this issue before? do you think this is required for LEED minimum energy performance credit compliance (ASRAE 90.1)? Sadly I could not find much information about it, and whether is necessary to account for this for not. Thanks |
2023-03-17 10:07:53 -0500 | received badge | ● Scholar (source) |
2023-03-16 09:19:04 -0500 | commented answer | Mall entrance infiltration modeling for LEED compliance Hi Keigo, Thanks for the input. However, I was referring to the entrance infiltration through the doors. I assume this |
2023-03-16 06:27:46 -0500 | edited question | Misc vs plug loads Misc vs plug loads Hi there, I am currently carrying out an energy model for an office building. I would like to includ |
2023-03-16 06:24:31 -0500 | asked a question | Misc vs plug loads Misc vs plug loads Hi there, I am currently carrying out an energy model for an office building. I would like to includ |
2023-03-14 15:30:56 -0500 | edited question | Mall entrance infiltration modeling for LEED compliance Mall entrance infiltration modeling for LEED compliance Hi there, I am currently carrying out an energy modeling for a |
2023-03-14 15:30:39 -0500 | asked a question | Mall entrance infiltration modeling for LEED compliance Mall entrance infiltration modeling for LEED compliance Hi there, I am currently carrying out energy modeling for a sho |
2023-03-13 08:20:23 -0500 | commented answer | Mall unregulated loads I was wondering how to address the cinema plug loads calculation, do you have any recommendations for this? Thanks |
2023-03-13 08:19:38 -0500 | commented answer | Mall unregulated loads I was wondering how to address the cinema energy loads calculation, do you have any recommendations for this? Thanks |
2023-03-10 03:59:40 -0500 | commented answer | Mall unregulated loads Great, thank you very much Joshua. |
2023-03-10 03:57:36 -0500 | received badge | ● Supporter (source) |
2023-03-09 09:32:00 -0500 | asked a question | Revolving doors impact in energy model ASHRAE 90.1 Revolving doors impact in energy model ASHRAE 90.1 Dear all, I am currently carrying out an energy performance calculat |
2023-03-08 13:28:05 -0500 | edited question | Mall unregulated loads Mall unregulated loads Dear all, I am currently assessing al the unregulated loads in a mall building. In this case the |
2023-03-08 13:28:05 -0500 | received badge | ● Editor (source) |
2023-03-08 13:24:33 -0500 | asked a question | Mall unregulated loads Mall unregulated loads Dear all, I am currently assessing al the unregulated loads in a mall building. In this case the |
2023-03-07 09:57:15 -0500 | commented answer | small thermal zones Thank you very much for your reply. It is more clear now. |
2023-03-07 01:39:37 -0500 | answered a question | small thermal zones Hi again, Have you faced this issue before? Can anyone give me a hint? Thank |
2023-02-27 08:50:51 -0500 | received badge | ● Student (source) |
2023-02-27 08:43:59 -0500 | asked a question | small thermal zones small thermal zones Dear all, I am currently developing an energy model for a mall building. In this mall there are hun |