samks123's profile - activity

2023-12-06 06:25:36 -0500 received badge  Popular Question (source)
2019-05-20 11:44:37 -0500 edited question Cosimulation Energyplus/Openstudio-FMU

Cosimulation Energyplus/Openstudio-FMU I have created an OpenStudio building model using as a base the SmallHotel exampl

2019-05-20 08:11:12 -0500 asked a question Cosimulation Energyplus/Openstudio-FMU

Cosimulation Energyplus/Openstudio-FMU I have created an OpenStudio building model using as a base the SmallHotel exampl

2017-11-09 14:53:09 -0500 received badge  Popular Question (source)
2017-03-29 10:02:29 -0500 commented question EnergyPlus SOFC Fuel Cell-mCHP
2017-03-29 09:59:21 -0500 commented question EnergyPlus SOFC Fuel Cell-mCHP

@MatthewSteen. That is bad..I will immediately remove it then.

2017-03-28 20:29:32 -0500 asked a question EnergyPlus SOFC Fuel Cell-mCHP

Hi All,

Can anyone assist on modelling a gas fuelled Fuel Cell m-CHP in a domestic dwelling? The type of energy system that I am trying to model is similar to the one shown in the image below:

image description

The building modelling is already modelled on EnergyPlus, however, I am trying to adapt it with fuel cells. The unique example I saw from the EnergyPlus documentation is the MicroCogeneration.idf file. The example file is based on the REFERENCE: "Experimental Investigation of Residential Cogeneration Devices and Calibration of Annex 42 Models." A report of Subtask B of IEA/ECBCS Annex 42, which is available from http://www.ecbcs.org/annexes/annex42.htm.

It is being a bit frustrating because even in the Energyplus HTML-documentation (http://bigladdersoftware.com/epx/docs...) I found it very hard to understand. Hence, a bunch of errors...

For any interest, my .idf file is also attached here: https://www.dropbox.com/s/3gkl2sss9tf...

2016-04-12 07:58:11 -0500 commented answer EnergyPlus-GenOpt Calibration not Working with ExcalibBEM interface

@Julien Marrec, thanks for editing the post and commenting. I am still finding difficulties to spot the backslah with quote that is missing in the cfg. This should be written automatically because it is generated using the ExcalibBEM interface. I am finding this issue with my model only. The example files are working perfectly. I am actually starting to assume that the problem have to do with the python file...

2016-04-12 07:58:11 -0500 received badge  Commentator
2016-04-11 18:26:14 -0500 commented answer EnergyPlus-GenOpt Calibration not Working with ExcalibBEM interface

@ Michael Wetter, see edit in my answer for the cfg file.

I cannot figure out where I am missing a bracket : ), },...? or \"

Thanks!

2016-04-10 19:17:33 -0500 asked a question EnergyPlus-GenOpt Calibration not Working with ExcalibBEM interface

I am actually using the interface ExcalibBem to calibrate an idf file simulation with a measured data and does not work at all. The objective is to match the Interior electrical equipment consumption of the model with the measured data, selecting several electrical equipment parameters. The error I get is as follows:

Error in executing the simulation program
Exit value of the simulation program: 1
Working directory : 'C:\Users\SambuKS\Desktop\EP_Calibration_MinOA\GenOpt\tmp-genopt-run-1'.
Current command String    : 'cmd /C ""C

The model is uploaded here

Edit:

Here is my .cfg file:

this is the cfg file configuration:

SimulationStart

{

// The command line below calls RunEPlus.bat.

Command = "cmd /C \"\"C:\\Users\\SambuKS\\Desktop\\My Model\\GenOpt\\Calib.bat\" \"%Simulation.Files.Input.File1%\" \"%Simulation.CallParameter.Suffix%\" \"C:\\EnergyPlusV8-4-0\\\"  \"%Simulation.CallParameter.Prefix%\"\"";

    WriteInputFileExtension = false;
}
2016-04-10 18:18:17 -0500 commented question Space Heat Demand

@rraustad. Thanks very much for your kind intention of assisting, but this case is now solved. Regards,

2016-02-25 08:25:09 -0500 commented question Domestic Hot Water Demand in EnergyPlus

@Chris Jones, I think you are right, I came to that conclusin yesterday. What typical values are assigned for the Flow Rate Fraction Schedule Name i toilets and/or kitchen?

Regards,

SAMBU.K

2016-02-24 08:23:36 -0500 asked a question Space Heat Demand

I have a model named EZEBH_SAHP , another model named GHZEBH_SABLR and a last model named CHZEBH_SC. The EZEBH_SAHP and GHZEBH_SABLR have the same U-values, but the CHZEBH has lower U-values than the other two models.

That means that EZEBH_SAHP and GHZEBH_SABLR should have the same space heating demand, and lower space heating demand than CZEBH_SC, however, when I run the simulations and compare the three models, GHZEBH_SABRLR has higher space heating demand than CHZEBH_SC.

I have done the following in order to obtain the space heating demand (according to energyplus helpserve):

That can be tricky depending on the type of equipment you are modeling. "Zone Air System Predicted Sensible Load to Heating" is not a good choice if you plan to sum the value over time, because it represents the load required to reach the setpoint at the current timestep. If the load is not met, then any remaining load may be included again in the next time step.

For forced air systems, Zone Air System Sensible Heating Energy reflects the amount of heat that the system actually delivered to the space. This can be summed over time and will reflect the heating requirement as long as the system meets the load. The purest approach is to use the ideal loads air system which will always meet the load exactly.

For other system types, such as baseboard and radiant heat, you need to report the specific equipment output, such as Baseboard Total Heating.

To determine the heating demand without internal gains, you need to run a second simulation with all of the gains scheduled off.

See files attached in this link: https://www.dropbox.com/sh/l35w7efhur...

Regards,

SAMBU.K

2016-02-24 08:06:13 -0500 asked a question Domestic Hot Water Demand in EnergyPlus

Dear Sir/Madam,

How can I obtain in the output simulation of the Domestic Hot Water Demand? I noticed that on my model (attached), the water consumption is too low. What could be the reason?

I have modelled in the Activities module, a water rconsumption of 150 litres per person a day.

Link to the idf file: https://www.dropbox.com/sh/26p5qznqfb...

Regards,

SAMBU. K

2015-12-08 03:29:11 -0500 commented answer GenOpt/EnergyPlus-Best Algorithm for peak load reduction (load-shift)

@Julien, and @GilbertLM thanks very much.Will give a try to ExcalibBEM

2015-12-07 05:43:37 -0500 commented question GenOpt/EnergyPlus-Best Algorithm for peak load reduction (load-shift)

@Julien. Yes indeed. Thanks again

2015-12-07 04:17:50 -0500 asked a question GenOpt/EnergyPlus-Best Algorithm for peak load reduction (load-shift)

I am actually trying to develop an algorithm to shift the load demand during on-peak hours using GenOpt. I have had a quick trial testing the example file HookJeeves Algorithm, however I have some doubts in order to achieve my target.

I would like to start with something very simple such as:

$\min_{J} : C(t) dt$

Where,

$C(t) = [P_{HP} + P_{DHW} +...] * TimeOfUse (t) $

  • $C(t)$ : Cost function

  • $TimeOf Use(t)$ : on-peak hour tariff prices and off-peak hour tariff prices

  • $P_{HP}$: Power associated to a Heat Pump

  • $P_{DHW}$ : Power associated to the Domestic Hot Water

and,

  • 18C <= Temperature indoor<= 21C

  • 45C <= Temperature Domestic Hot Water<= 55C

Therefore, I am not too sure if HookJeeves is the best algorithm to use for this case, and if it is, how can I set the time of use parameter and constraint the temperatures.

2015-12-04 17:33:48 -0500 received badge  Scholar (source)
2015-12-04 06:23:44 -0500 commented answer Error trying to run GenOpt

@Julien, THANKS VERY MUCH!!! It finally works with no errors at all.

Regards,

2015-12-02 16:54:25 -0500 answered a question Error trying to run GenOpt

@ Julien, thanks for your reply. I have modified the RunEplusParallel.bat file to mathc my latest E+version, however, it does not work. See below...

: Currently, there is no environment variable that points to the E+ directory. : We hard-code it here.
set program_path=C:\Program Files\EnergyPlusV8-3-3\

I addition, I have added all files on my current E+plus folder: (C:\Users\SambuKS\Documents\GenOpt\example\energyplus\7_0_0\GPSHookeJeeves). See image attached below : image description

Thanks again!

2015-12-02 16:40:50 -0500 commented answer How to run GenOpt?

Thanks for your reply Gilbert, unfortunately that does not works.... See below:

C:\Users\SambuKS>Documents\GenOpt\example\energyplus\7_0_0\GPSHookeJeeves\tmp-ge nopt-run-1> The syntax of the command is incorrect. C:\Users\SambuKS>cd.. C:\Users>cd..

C:>\Users\SambuKS\Documents\GenOpt\example\energyplus\7_0_0\GPSHookeJeeves\tmp- genopt-run-1 '\Users\SambuKS\Documents\GenOpt\example\energyplus\7_0_0\GPSHookeJeeves\tmp-gen opt-run-1' is not recognized as an internal or external command, operable program or batch file

2015-12-02 12:03:33 -0500 received badge  Teacher (source)
2015-12-02 11:01:33 -0500 asked a question Error trying to run GenOpt

I am actually facing an issue with GenOpt.

The error that I am obtaining when I try to run the first tutorial (GenOpt\example\energyplus\7_0_0\GPSHookeJeeves) is as follows:

------------------------------------------------------------------------------------------------------------------------------------------- 
Assigning 4 threads for simulations.
Initialize.
java.lang.Exception: 

Exception in executing the simulation program

Simulation working directory : 'C:\Users\SambuKS\Documents\GenOpt\example\energyplus\7_0_0\GPSHookeJeeves\tmp-genopt-run-1'
Command string               : 'cmd /C ""C:\Program Files (x86)\EnergyPlusV7-0-0\RunEPlus.bat" "singleZonePurchAir" "USA_IL_Chicago-OHare.Intl.AP.725300_TMY3""'
Exception message: 

Error in executing the simulation program
Exit value of the simulation program: 1
Working directory                   : 'C:\Users\SambuKS\Documents\GenOpt\example\energyplus\7_0_0\GPSHookeJeeves\tmp-genopt-run-1'.
Current command String              : 'cmd /C ""C:\Program Files (x86)\EnergyPlusV7-0-0\RunEPlus.bat" "singleZonePurchAir" "USA_IL_Chicago-OHare.Intl.AP.725300_TMY3""'.
Error stream of simulation program  : The system cannot find the path specified.


GenOpt terminated with error.
See logfile for further information.
--------------------------------------------------------------------------------------------------------------------

Looks like it is looking for Eplus.bat Version 7.....

  • I have updated the E+ version by using the IDFVersionUpdater. From v7 to v8.3 .

  • In addition, as there is no 'RuenEplusPaarallel.bat' file at the 'energyplus7_0_0' folder I copied one from 'energyplus5_0_0' folder.

  • I have also considered to change the weather file versions to the latest ones from E+ v8.3.3.

Any suggestions?

2015-12-02 11:00:48 -0500 answered a question How to run GenOpt?

Hi All,

I am actually facing the same issues with GenOpt.

The error that I am obtaining when I try to run the first tutorial (GenOpt\example\energyplus\7_0_0\GPSHookeJeeves) is as follows:


Assigning 4 threads for simulations. Initialize. java.lang.Exception:

Exception in executing the simulation program

Simulation working directory : 'C:\Users\SambuKS\Documents\GenOpt\example\energyplus\7_0_0\GPSHookeJeeves\tmp-genopt-run-1' Command string : 'cmd /C ""C:\Program Files (x86)\EnergyPlusV7-0-0\RunEPlus.bat" "singleZonePurchAir" "USA_IL_Chicago-OHare.Intl.AP.725300_TMY3""' Exception message:

Error in executing the simulation program Exit value of the simulation program: 1 Working directory : 'C:\Users\SambuKS\Documents\GenOpt\example\energyplus\7_0_0\GPSHookeJeeves\tmp-genopt-run-1'. Current command String : 'cmd /C ""C:\Program Files (x86)\EnergyPlusV7-0-0\RunEPlus.bat" "singleZonePurchAir" "USA_IL_Chicago-OHare.Intl.AP.725300_TMY3""'. Error stream of simulation program : The system cannot find the path specified.

GenOpt terminated with error.

See logfile for further information.

Looks like it is looking for Eplus.bat Version 7.....

  • I have updated the E+ version by using the IDFVersionUpdater. From v7 to v8.3 .

  • In addition, as there is no 'RuenEplusPaarallel.bat' file at the 'energyplus7_0_0' folder I copied one from 'energyplus5_0_0' folder.

-I have also considered to change the weather file versions to the latest ones from E+ v8.3.3.

Any suggestions???

Best Regards,

2015-09-18 19:31:31 -0500 commented question Boiler:HotWater does not work!!!!

@Julien Marrec, the issue has been solved in energyplus support desk. It had to do with the radiators component sizing. They were oversized. Thanks very much for your collaboration. My email is sambukanteh@gmail.com. All the best!

2015-09-18 09:57:33 -0500 commented question Boiler:HotWater does not work!!!!

@Julien Marrec, Thanks Julien. I had to update the file from E+v8.1 to E+v8.3, and then correct some errors that the simulation was providing. I will try to update the version to 8.3 and share it with. In addition, I will draw the E+ diagram including equipments and setpoints. Thanks

2015-09-18 05:14:15 -0500 asked a question Boiler:HotWater does not work!!!!

Hi All!

I have modelled an energy system for a domestic dwelling to provide space heating and and domestic hot water. The system consists on a solar thermal panel with storage tank assisted by a gas fired condensing boiler (see diagram). However, the boiler does not works at all. image description

The connections seems to be OK. Any suggestions please?

Please see below a link of the .idf file.

https://www.dropbox.com/s/hezn0rve6nw...

Best Regards,

SAMKS

2015-07-07 11:30:44 -0500 received badge  Editor (source)
2015-07-03 16:50:41 -0500 answered a question model a water to water heat pump (Equation Fit Approach)

Hi, Thanks your response!

I have exactly done what you suggested. In this case I decided to connect the wwhp between the solar collectors and water heater (E_Schematic). The diagram, and the idfile is also attached in this email. However, I am getting an error that I cannot figure out. I do not know why it is requesting me or providing me an error of placing a pump at each plant loop. I am trying to avoid the heatExchanger, but if it is required to finish the modelling I will do so.

Please, any suggestions?

Thanks,

SAMBUC:\fakepath\E__Schematic.jpg

C:\fakepath\Solar PVT.jpg

2015-06-29 13:35:16 -0500 received badge  Student (source)
2015-04-06 13:25:18 -0500 asked a question model a water to water heat pump (Equation Fit Approach)

How can I model a water to water heat pump between a solar collector and water heater.

Is there any example file from energyplus? In addition of the documentation, as I went through it but is not clear to me the steps.

Note: This model is a special case as usually water to water heat pumps are made to perform with ground source heat exchangers.


Update

Hi, Thanks your response!

I have exactly done what you suggested. In this case I decided to connect the wwhp between the solar collectors and water heater (E_Schematic). The diagram, and the idfile is also attached in this email. However, I am getting an error that I cannot figure out. I do not know why it is requesting me or providing me an error of placing a pump at each plant loop. I am trying to avoid the heatExchanger, but if it is required to finish the modelling I will do so.

Please, any suggestions?

Thanks,

SAMBUC:\fakepath\E__Schematic.jpg

C:\fakepath\Solar PVT.jpg

THIS IS THE DIAGRAM C:\fakepath\Solar PVT assissted by a heatpump.jpg