2021-11-03 12:27:55 -0500 commented question Openstudio 3.2.1 Review

I can say the bugs related to modeling the HVAC and applying the measures. Especially when exported to the. idf files,

2021-11-03 05:30:52 -0500 edited question Openstudio 3.2.1 Review

Openstudio 3.2.1 Review I would appreciate it if you share some reviews for the last release of Open studio (3.2.1). I

2021-11-03 05:29:12 -0500 asked a question Openstudio 3.2.1 Review

Openstudio 3.2.1 Review I would appreciate it if you share some reviews for the last release of Open studio (3.2.1). I

2021-04-09 12:51:32 -0500 edited question problem with Air to water heat pump results in energy plus

problem with Air to water heat pump results in energy plus Hi, I have modeled an air to water heat pump in energy plus

2021-04-09 12:50:38 -0500 edited question problem with Air to water heat pump results in energy plus

problem with Air to water heat pump results in energy plus Hi, I have modeled an air to water heat pump in energy plus

2021-04-09 12:49:57 -0500 edited question problem with Air to water heat pump results in energy plus

problem with Air to water heat pump results in energy plus Hi, I have modeled an air to water heat pump in energy plus

2021-04-09 12:49:12 -0500 asked a question problem with Air to water heat pump results in energy plus

problem with Air to water heat pump results in energy plus Hi, I have modeled an air to water heat pump in energy plus

2021-01-28 10:24:22 -0500 asked a question Generate fully enclosed zones

Generate fully enclosed zones I would like to activate "Generate fully enclosed zones" in my design builder model, but t

2019-12-19 13:17:06 -0500 received badge  Enthusiast
2019-12-12 11:13:42 -0500 edited question Error: No windows found in selection matching given construction.

Error: No windows found in selection matching given construction. Hi Every one. I want to use the "add Wind and Stack O

2019-12-12 11:13:33 -0500 edited question Error: No windows found in selection matching given construction.

Error: No windows found in selection matching given construction. Hi Every one. I want to use the "add Wind and Stack O

2019-12-12 11:13:15 -0500 asked a question Error: No windows found in selection matching given construction.

Error: No windows found in selection matching given construction. Hi Every one. I want to use the "add Wind and Stack O

2019-12-12 10:57:18 -0500 answered a question Missing window construction in "Wind and Stack Open Area" measure

Hi I have faced with the same error in my simulation. Then I checked the issues that has been discussed in the comments.

2019-06-18 03:32:54 -0500 commented answer Add compact schedule in open studio

Thanks David for your response. I did as you explained. However it is not possible to edit the compact schedule in OS? A

2019-06-12 10:47:00 -0500 commented question Fix the operative temperature of the zone

Thank you for your reply...I am comparing the results of energy plus with a new developed software ( that is in the phas

2019-06-12 05:03:23 -0500 commented question Fix the operative temperature of the zone

Thanks for your reply....The deviation is not constant. It is between 0 and 0.5. Where can I manage the dead band in ene

2019-06-10 10:39:01 -0500 edited question Fix the operative temperature of the zone

Fix the operative temperature of the zone /urgent Hi guys. In am modelling a building with ideal load system. In my mod

2019-06-10 09:28:02 -0500 edited question Fix the operative temperature of the zone

Fix the operative temperature of the zone /urgent Hi guys. In am modelling a building with ideal load system. In my mod

2019-06-10 09:26:43 -0500 edited question Fix the operative temperature of the zone

Fix the operative temperature Hi guys. In am modelling an ideal load system. In my model I would like to fix the operati

2019-06-10 09:24:18 -0500 asked a question Fix the operative temperature of the zone

Fix the operative temperature Hi guys. In am modelling an ideal load system. In my model I would like to fix the operati

2019-06-03 07:05:01 -0500 asked a question set "Maximum Sensible Heating Capacity" in open studio

set "Maximum Sensible Heating Capacity" in open studio Hi guys, In Ideal load option, I have set the heating capacity t

2019-05-29 03:50:56 -0500 commented answer Any suggestion why the load results are not reasonable!!!

Thank you very much for your explanation. I really appreciate your support.

2019-05-29 03:39:26 -0500 commented answer Edit thermostat set point object

Thank you very much for your response. As I have seen many videos editing it in the inspector ( regarding previous versi

2019-05-28 08:56:56 -0500 edited question Edit thermostat set point object

Edit thermostat set point object Hi Guys, In my open studio model I assign thermostat to Zones ( ideal load) , with the

2019-05-28 08:55:13 -0500 edited question Edit thermostat set point object

Edit thermostat set point object Hi Guys, In my open studio model I assign thermostat to Zones, with the "set attribute

2019-05-28 08:54:37 -0500 asked a question Edit thermostat set point object

Edit thermostat set point object Hi Guys, In my open studio model I assign thermostat to Zones, with the "set attribute

2019-05-27 05:43:05 -0500 edited question Add compact schedule in open studio

Add compact schedule in open studio Guys, How it is possible to add a compact schedule in open studio version 2.8? I ha

2019-05-27 05:39:58 -0500 asked a question Add compact schedule in open studio

Add compact schedule in open studio Guys, How it is possible to add a compact schedule in open studio version 2.8? I ha

2019-05-24 19:20:59 -0500 commented answer Any suggestion why the load results are not reasonable!!!

Regarding the design days, I know that it would be used for HVAC sizing....as I am pretty new ,I am not sure about it an

2019-05-24 19:19:50 -0500 commented answer Any suggestion why the load results are not reasonable!!!

Thank you very much for checking the model. Actually I’m running the simulation to analyze Energy need Just considering

2019-05-24 13:13:37 -0500 commented question Any suggestion why the load results are not reasonable!!!

This is the link of the model: https://we.tl/t-KgqOnI9TWt Thank you very much for your help .

2019-05-24 10:35:40 -0500 asked a question ideal air load measure error

ideal air load measure error Guys, In the "Ideal load option" measure of the open studio, I have chose "use individual

2019-05-24 10:33:30 -0500 commented answer Outside Air -Ideal Loads

Guys, I have more or less the same problem that i cannot fix... In the "Ideal load option" measure of the open studio, I

2019-05-24 10:33:20 -0500 received badge  Commentator
2019-05-24 10:33:20 -0500 commented answer Outside Air -Ideal Loads

Guys, I have more or less the same problem that i cannot fix... In the "Ideal load option" measure of the open studio, I

2019-05-24 03:56:36 -0500 commented answer measure does not appear in library

Thanks David...The problem has solved . I really appreciate your help and support.

2019-05-23 13:27:05 -0500 commented question Any suggestion why the load results are not reasonable!!!

Thanks for you comment. I have modeled the building, without any HVAC, defining ideal air load (unlimited)...I did not d

2019-05-23 13:26:38 -0500 commented question Any suggestion why the load results are not reasonable!!!

Thanks for you comment. I have modeled the building, without any HVAC, defining ideal air load...I did not defined any d

2019-05-23 07:27:17 -0500 asked a question Any suggestion why the load results are not reasonable!!!

Any suggestion why the load results is not resealable!!! Hi every one, I have modeled a building in open studio with id

2019-05-23 05:00:57 -0500 commented question Facing error when applying a measure

Thanks David very much for your help:) I have actually faced this error after altering the weather location.

2019-05-23 05:00:55 -0500 commented question Facing error when applying a measure

Thanks David very much for your help:) I have actually face this error after altering the weather location.

2019-05-23 04:57:31 -0500 commented question Difference in E+ results

Dear David, Thank you so much for your answer. Yes I have used many Energy plus measures and I thought they would be exp

2019-05-23 04:54:55 -0500 commented answer measure does not appear in library

Dear David,Thanks for you help. I did exactly what you have explained here ( altering the weather city name) , but the s

2019-05-23 04:54:45 -0500 commented answer measure does not appear in library

Dear David,Thanks for you help. I did exactly what you have explained here ( altering the weather city name) , but the s

2019-05-23 04:54:19 -0500 commented answer measure does not appear in library

Dear David,Thanks for you help. I did exactly what you have explained here ( altering the weather city name) , but the s

2019-05-23 04:53:44 -0500 edited question measure does not appear in library

measure does not appear in library Hi Guys, I am trying to add the "AedgSlabAndBasement" measure yo my model.I download

2019-05-23 04:53:38 -0500 commented answer measure does not appear in library

Dear David,Thanks for you help. I did exactly what you have explained here ( altering the weather city name) , but the s

2019-05-22 16:08:16 -0500 edited question Difference in E+ results

Difference in E+ results Hi everyone, I have noticed a difference between the results of the “district heating meter” Wh

2019-05-22 16:07:09 -0500 edited question Difference in E+ results

Difference in results Hi everyone, I have noticed a difference between the results of the “district heating meter” When

2019-05-22 16:03:38 -0500 asked a question Difference in E+ results

Difference in results Hi everyone, I have noticed a difference between the results of the “district heating meter” When