2021-11-10 16:26:33 -0500 | marked best answer | 3242 Severe errors - Controller error for controller=cooling water coil I am unable to tweak this error which I got while running for full year simulation. I have set one chiller feed to TES and TES to the Colling coil in the secondary Chilled water loop. I have set the Controller for water coil as The error I am getting is While I am still trying to understand the SimHVAC iteration fix based on the suggestions here https://unmethours.com/question/17449...
IDF file -http://pastebin.com/MV1ET0dS
|
2021-08-09 09:20:27 -0500 | received badge | ● Famous Question (source) |
2021-06-19 08:17:40 -0500 | received badge | ● Notable Question (source) |
2021-06-19 08:17:40 -0500 | received badge | ● Popular Question (source) |
2020-05-09 17:07:06 -0500 | marked best answer | Chiller selection/modification for Ice storage I am using the chillers provided by default for the CHILLER:ELECTRIC:REFORMULATEDEIR as Bicubic:ReformEIRChiller Carrier 19XR 1259kW/6.26COP/Vanes EIRFPLR, Biquadratic:WC Screw Default 90.1-2004 Cap_fT Biquadratic:WC Screw Default 90.1-2004 EIR_fT Minimum temperature from the chiller outlet should be as low as (-)10 oC, The range of the leaving CW Temp is set 0 to 20. Is it safe to modify the range to meet the low temperature and get valid performance? The Included Chillers.idf have the curves with even narrower temperature range with the minimum around 4 oC. I am getting some errors and I suspect they might be due to this limitation. (more) |
2020-04-29 03:51:56 -0500 | received badge | ● Taxonomist |
2020-03-04 13:50:50 -0500 | edited question | AedgK12 Hvac Dual Duct Doas generates single duct system instead of dual duct? AedgK12 Hvac Dual Duct Doas generates single duct system instead of dual duct? I just tried the AedgK12HvacDualDuctDoas |
2020-03-04 13:39:29 -0500 | asked a question | AedgK12 Hvac Dual Duct Doas generates single duct system instead of dual duct? AedgK12 Hvac Dual Duct Doas generates single duct system instead of dual duct? I just tried the AedgK12HvacDualDuctDoas |
2020-02-28 09:08:24 -0500 | commented answer | Dedicated Outside Air in Openstudio This might not work the same as the DOAS unit has its own HW and CHW coils to precondition outdoor air that distributed |
2020-02-27 09:02:16 -0500 | commented question | Dedicated Outside Air in Openstudio Advanced output from the DOAS measure is here https://justpaste.it/2jwu0 |
2020-02-27 09:00:37 -0500 | commented question | Dedicated Outside Air in Openstudio I did try that measure. Does but ended up with RTTI data error like this: Standard Output: [BOOST_ASSERT] Assertion wo |
2020-02-26 16:48:24 -0500 | commented question | Missing inlet node name, different problem You might have some coils where they are not connected on the airside while still connected with the plant loop. |
2020-02-26 09:55:47 -0500 | edited question | Dedicated Outside Air in Openstudio Dedicated Outside Air in Openstudio I know this used to be difficult in an earlier version of Openstudio. But, I haven't |
2020-02-26 09:55:26 -0500 | commented question | Dedicated Outside Air in Openstudio @petros Yes, both the coils are connected in the boiler loop and chiller loop. it's just not showing the connection node |
2020-02-24 12:00:41 -0500 | asked a question | Dedicated Outside Air in Openstudio Dedicated Outside Air in Openstudio I know this used to be difficult in an earlier version of Openstudio. But, I haven't |
2020-02-24 11:33:19 -0500 | asked a question | Duplicating an DDVAV AHU in openstudio crashes model Duplicating an DDVAV AHU in openstudio crashes model I am trying to model a building with around 15 AHU's and most of th |
2020-01-03 10:17:04 -0500 | asked a question | Outside air temperature based setpoints Outside air temperature based setpoints Is it possible to define setpoint based on outside air temperature in EnergyPlus |
2019-11-26 05:01:25 -0500 | received badge | ● Popular Question (source) |
2018-10-18 11:04:03 -0500 | commented question | Modifying battery storage operation scheme @Divya Check here https://energyplus.net/documentation/ . Also, look into the example files, you might find similar mode |
2018-10-11 15:35:31 -0500 | marked best answer | eplusout.eso in excel How can we view the resulting variable in excel for further processing or analysis. I have Openstudio but not able to figure out the way to use the ReadVarESO for this. Is there a tutorial detailing the possibilities. I need the breakup in simple form so that I can compare and replicate my model developed in HAP which does not allow custom optimizations . |
2018-10-03 21:07:20 -0500 | marked best answer | How to fix-Openstudio: input file errors and warnings I saw the other posting asking the question about input files but its beyond my understanding, so please help. My model is gone almost ok but I get these errors when i open the OSM file:
How do I fix these? Can these be ignored? I dont know the ruby console commands and its application and would like some help here. |
2018-10-02 08:54:20 -0500 | marked best answer | Warning design cooling coil US I am getting the following warnings, and I wanted to know the significance of these. I picked Cooling coil water and Chiller:Electric: EIR based on an example idf file. Error files include: |
2018-06-15 15:59:44 -0500 | edited question | Defining DualDuct Air Terminal Unit with reheat in OpenStudio Defining DualDuct Air Terminal Unit with reheat in OpenStudio I am trying to model a building with many DuralDuct AHU's |
2018-06-15 15:59:17 -0500 | asked a question | Defining DualDuct Air Terminal Unit with reheat in OpenStudio Defining DualDuct Air Terminal Unit with reheat in OpenStudio I am trying to model a building with many DuralDuct AHU's |
2018-06-15 09:37:37 -0500 | commented answer | Proper Dual Duct Setpoints @DW can you update the post with the correct screenshot showing what changes you made. |
2018-06-15 09:36:28 -0500 | answered a question | Proper Dual Duct Setpoints @DW can you update the post with the correct screenshot showing what changes you made. |
2018-05-23 09:20:27 -0500 | edited question | Ice storage model fluctuations during discharge Ice storage model fluctuations during discharge I have an ice storage model that is showing fluctuations in many output |
2018-05-22 21:56:30 -0500 | asked a question | Ice storage model fluctuations during discharge Ice storage model fluctuations during discharge I have a ice storage model that is showing fluctuations in many output |
2018-05-02 15:31:57 -0500 | edited question | GetSurfaceData errors and failure GetSurfaceData errors and failure I am trying to model a rather detailed 5-6 floor building that does not have symmetric |
2018-05-02 15:20:24 -0500 | edited question | GetSurfaceData errors and failure GetSurfaceData errors and failure I am trying to model a rather detailed 5-6 floor building that does not have symmetric |
2018-05-02 15:10:41 -0500 | asked a question | GetSurfaceData errors and failure GetSurfaceData errors and failure I am trying to model a rather detailed 5-6 floor building that does not have symmetric |
2018-05-02 14:34:21 -0500 | received badge | ● Popular Question (source) |
2018-05-02 10:45:25 -0500 | marked best answer | OpenStudio Crashes while selecting plant loop I noticed this on multiple OSM files recently that openstudio just crashes when I select to open the plant loop or condenser loop. Earlier I had to abandon and start with the new OSM file because of this issue. But even this OSM file started crashing. I am assuming it is due to some wrong entries but it could be a bug not letting fix it? I am sharing the txt version of the file for the experts to review https://paste2.org/hVMKnzFP |
2018-05-02 10:45:21 -0500 | commented answer | OpenStudio Crashes while selecting plant loop I missed the ; . Forgot all the Eplus editing rules as i havent been workinng with E+ lately. Now the model runs complet |
2018-05-02 08:46:00 -0500 | commented answer | OpenStudio Crashes while selecting plant loop @Avi Did you manually locate the error while going through the file or you used some diagnostic script to locate the iss |
2018-05-02 08:40:52 -0500 | commented answer | OpenStudio Crashes while selecting plant loop @Avi Did you manually locate the error while going through the file or you used some diagnostic script to locate the iss |
2018-05-02 08:33:24 -0500 | commented answer | OpenStudio Crashes while selecting plant loop Thanks @Julien Marrec for taking it forward. But, I did edit the model. |