2019-12-19 04:17:03 -0500 | commented answer | Multiple-year Simulation The new energyplus version(9.2.0) enable to read multiyear EPW file. |
2019-12-05 05:34:58 -0500 | answered a question | EMS routine doesn't work Here is the solution: EnergyManagementSystem:Program, Window_Jones_2017, !- Name if Window1_S1_act == Null, set W |
2019-11-19 02:38:27 -0500 | commented question | why Fin or Overhang Projection impact are not similar than shading objet ? Hello everyone, I investigated the problem and it seems that there is a problem with horizontal shade. I compare manual |
2019-10-28 05:00:44 -0500 | commented question | EMS routine doesn't work I add the object: Output:EnergyManagementSystem, Verbose, Verbose, Verbose; In order to show all ems step in the out |
2019-10-28 04:56:36 -0500 | commented question | EMS routine doesn't work I add the object: Output:EnergyManagementSystem, Verbose, Verbose, Verbose; In order to show all ems step in the out |
2019-10-28 04:56:03 -0500 | commented question | EMS routine doesn't work I add the object: Output:EnergyManagementSystem, Verbose, Verbose, Verbose; In order to show all ems step in the out |
2019-10-28 02:23:42 -0500 | commented question | EMS routine doesn't work Do you have an "EnergyManagementSystem:ProgramCallingManager" declare when to run your programs ? |
2019-10-25 11:33:20 -0500 | edited question | why Fin or Overhang Projection impact are not similar than shading objet ? why Fin or Overhang Projection impact are not similar than shading objet ? Hello, I've studied the impact of "Shading: |
2019-10-25 10:55:12 -0500 | edited question | why Fin or Overhang Projection impact are not similar than shading objet ? why Fin or Overhang Projection impact are not similar than shading objet ? Hello, I've studied the impact of "Shading: |
2019-10-25 10:55:08 -0500 | edited question | why Fin or Overhang Projection impact are not similar than shading objet ? why Fin or Overhang Projection impact are not similar shading objet ? Hello, I've studied the impact of "Shading:Overh |
2019-10-25 10:54:38 -0500 | asked a question | why Fin or Overhang Projection impact are not similar than shading objet ? why Fin or Overhang Projection impact are not similar shading objet ? Hello, I've studied the impact of "Shading:Overh |
2019-09-11 09:46:48 -0500 | commented question | why ZoneHVAC:OutdoorAirUnit "Zone Outdoor Air Unit Total Heating Rate" output is not equal to its "Heating Coil Heating Rate" ? It seems that the coil rate is the correct rate to take into account for system rate |
2019-09-11 09:46:40 -0500 | edited answer | why ZoneHVAC:OutdoorAirUnit "Zone Outdoor Air Unit Total Heating Rate" output is not equal to its "Heating Coil Heating Rate" ? It seems that the coil rate is the correct rate to take into account for system rate. |
2019-09-11 09:46:40 -0500 | received badge | ● Editor (source) |
2019-09-11 09:46:15 -0500 | answered a question | why ZoneHVAC:OutdoorAirUnit "Zone Outdoor Air Unit Total Heating Rate" output is not equal to its "Heating Coil Heating Rate" ? It seems that the coil rate is the correct rate to take into account for system rate. |
2019-09-11 09:43:41 -0500 | asked a question | why ZoneHVAC:OutdoorAirUnit "Zone Outdoor Air Unit Total Heating Rate" output is not equal to its "Heating Coil Heating Rate" ? why ZoneHVAC:OutdoorAirUnit "Zone Outdoor Air Unit Total Heating Rate" output is not equal to its "Heating Coil Heating |
2019-08-05 09:37:08 -0500 | commented question | How to prevent Energy Plus Heat-Only Fan Coil Heating Coil from operating during call for cooling Are you mean air temperature or operative temperature for zone control thermosats ? |
2019-06-07 05:33:55 -0500 | answered a question | How to prevent Energy Plus Heat-Only Fan Coil Heating Coil from operating during call for cooling Are you mean air temperature or operative temperature for zone control thermosats ? |
2019-04-01 05:31:31 -0500 | answered a question | EnergyPlus EMS: internal variable Hello, it seems not possible to use actuator and internal variable at the zonegroup level for electricequipment object. |
2019-03-26 03:53:58 -0500 | edited answer | How can I retrieve schedule value after set it in an ems program (9.0.1) ? I found a way to solve it. The problem was the use of EnergyManagementSystem:Actuator instead of Sensor. An actuator va |
2019-03-26 03:48:32 -0500 | asked a question | How manage daylight saving period for multi year simulation ? How manage daylight saving period for multi year simulation ? Is there a official way to specify daylight saving period |
2019-03-21 11:01:38 -0500 | received badge | ● Supporter (source) |
2019-02-25 10:57:54 -0500 | received badge | ● Teacher (source) |
2019-02-25 02:42:00 -0500 | received badge | ● Citizen Patrol (source) |
2019-02-25 02:39:12 -0500 | commented answer | How can I retrieve schedule value after set it in an ems program (9.0.1) ? Thanks for your help. |
2019-02-25 02:38:53 -0500 | answered a question | How can I retrieve schedule value after set it in an ems program (9.0.1) ? I found a way to solve it. The problem was the use of EnergyManagementSystem:Actuator setting schedule value to 0. So, |
2019-02-23 11:05:50 -0500 | received badge | ● Student (source) |
2019-02-22 12:07:29 -0500 | asked a question | How can I retrieve schedule value after set it in an ems program (9.0.1) ? How can I retrieve schedule value after set it in an ems program (9.0.1) ? I want set a schedule to 0 in january and the |
2019-02-22 08:48:51 -0500 | asked a question | How can I retrieve schedule after set it in an ems program ? How can I retrieve schedule after set it in an ems program ? I want set a schedule to 0 in january and then retrieve the |