Lefort-Antoine's profile - activity

2019-12-19 04:17:03 -0500 commented answer Multiple-year Simulation

The new energyplus version(9.2.0) enable to read multiyear EPW file.

2019-12-05 05:34:58 -0500 answered a question EMS routine doesn't work

Here is the solution: EnergyManagementSystem:Program, Window_Jones_2017, !- Name if Window1_S1_act == Null, set W

2019-11-19 02:38:27 -0500 commented question why Fin or Overhang Projection impact are not similar than shading objet ?

Hello everyone, I investigated the problem and it seems that there is a problem with horizontal shade. I compare manual

2019-10-28 05:00:44 -0500 commented question EMS routine doesn't work

I add the object: Output:EnergyManagementSystem, Verbose, Verbose, Verbose; In order to show all ems step in the out

2019-10-28 04:56:36 -0500 commented question EMS routine doesn't work

I add the object: Output:EnergyManagementSystem, Verbose, Verbose, Verbose; In order to show all ems step in the out

2019-10-28 04:56:03 -0500 commented question EMS routine doesn't work

I add the object: Output:EnergyManagementSystem, Verbose, Verbose, Verbose; In order to show all ems step in the out

2019-10-28 02:23:42 -0500 commented question EMS routine doesn't work

Do you have an "EnergyManagementSystem:ProgramCallingManager" declare when to run your programs ?

2019-10-25 11:33:20 -0500 edited question why Fin or Overhang Projection impact are not similar than shading objet ?

why Fin or Overhang Projection impact are not similar than shading objet ? Hello, I've studied the impact of "Shading:

2019-10-25 10:55:12 -0500 edited question why Fin or Overhang Projection impact are not similar than shading objet ?

why Fin or Overhang Projection impact are not similar than shading objet ? Hello, I've studied the impact of "Shading:

2019-10-25 10:55:08 -0500 edited question why Fin or Overhang Projection impact are not similar than shading objet ?

why Fin or Overhang Projection impact are not similar shading objet ? Hello, I've studied the impact of "Shading:Overh

2019-10-25 10:54:38 -0500 asked a question why Fin or Overhang Projection impact are not similar than shading objet ?

why Fin or Overhang Projection impact are not similar shading objet ? Hello, I've studied the impact of "Shading:Overh

2019-09-11 09:46:48 -0500 commented question why ZoneHVAC:OutdoorAirUnit "Zone Outdoor Air Unit Total Heating Rate" output is not equal to its "Heating Coil Heating Rate" ?

It seems that the coil rate is the correct rate to take into account for system rate

2019-09-11 09:46:40 -0500 edited answer why ZoneHVAC:OutdoorAirUnit "Zone Outdoor Air Unit Total Heating Rate" output is not equal to its "Heating Coil Heating Rate" ?

It seems that the coil rate is the correct rate to take into account for system rate.

2019-09-11 09:46:40 -0500 received badge  Editor (source)
2019-09-11 09:46:15 -0500 answered a question why ZoneHVAC:OutdoorAirUnit "Zone Outdoor Air Unit Total Heating Rate" output is not equal to its "Heating Coil Heating Rate" ?

It seems that the coil rate is the correct rate to take into account for system rate.

2019-09-11 09:43:41 -0500 asked a question why ZoneHVAC:OutdoorAirUnit "Zone Outdoor Air Unit Total Heating Rate" output is not equal to its "Heating Coil Heating Rate" ?

why ZoneHVAC:OutdoorAirUnit "Zone Outdoor Air Unit Total Heating Rate" output is not equal to its "Heating Coil Heating

2019-08-05 09:37:08 -0500 commented question How to prevent Energy Plus Heat-Only Fan Coil Heating Coil from operating during call for cooling

Are you mean air temperature or operative temperature for zone control thermosats ?

2019-06-07 05:33:55 -0500 answered a question How to prevent Energy Plus Heat-Only Fan Coil Heating Coil from operating during call for cooling

Are you mean air temperature or operative temperature for zone control thermosats ?

2019-04-01 05:31:31 -0500 answered a question EnergyPlus EMS: internal variable

Hello, it seems not possible to use actuator and internal variable at the zonegroup level for electricequipment object.

2019-03-26 03:53:58 -0500 edited answer How can I retrieve schedule value after set it in an ems program (9.0.1) ?

I found a way to solve it. The problem was the use of EnergyManagementSystem:Actuator instead of Sensor. An actuator va

2019-03-26 03:48:32 -0500 asked a question How manage daylight saving period for multi year simulation ?

How manage daylight saving period for multi year simulation ? Is there a official way to specify daylight saving period

2019-03-21 11:01:38 -0500 received badge  Supporter (source)
2019-02-25 10:57:54 -0500 received badge  Teacher (source)
2019-02-25 02:42:00 -0500 received badge  Citizen Patrol (source)
2019-02-25 02:39:12 -0500 commented answer How can I retrieve schedule value after set it in an ems program (9.0.1) ?

Thanks for your help.

2019-02-25 02:38:53 -0500 answered a question How can I retrieve schedule value after set it in an ems program (9.0.1) ?

I found a way to solve it. The problem was the use of EnergyManagementSystem:Actuator setting schedule value to 0. So,

2019-02-23 11:05:50 -0500 received badge  Student (source)
2019-02-22 12:07:29 -0500 asked a question How can I retrieve schedule value after set it in an ems program (9.0.1) ?

How can I retrieve schedule value after set it in an ems program (9.0.1) ? I want set a schedule to 0 in january and the

2019-02-22 08:48:51 -0500 asked a question How can I retrieve schedule after set it in an ems program ?

How can I retrieve schedule after set it in an ems program ? I want set a schedule to 0 in january and then retrieve the