2019-03-01 14:01:06 -0500 | commented answer | How can I use the Slab Preprocessor when the floor is not insulated ? thanks for the answers ! |
2019-02-28 13:54:33 -0500 | marked best answer | Why cooling loads appear during the cold months ? Heating/Cooling loads using E+ I am simulating a residential building (80 m2) using Energy-Plus to determine the Heating/Cooling loads through a typical meteorological year. for this purpose, I am using a simple HVAC with Zone control:Thermostat object.So, the aim is to predict the District:Cooling and District:Heating. Indeed, we now that cold months usually require heating loads only. however, as we look at the figure bellow, there are cooling loads in all months of the year. Any help !!!!! |
2019-02-28 13:42:22 -0500 | commented answer | Why cooling loads appear during the cold months ? Heating/Cooling loads using E+ Mr Richard Raustad, thanks a lot for your prompt response. In my silumation, I used an infltration of about 0.5 Air-chan |
2019-02-28 13:26:55 -0500 | commented answer | Why cooling loads appear during the cold months ? Heating/Cooling loads using E+ Mr Richard Raustad, thanks a lot for your prompt response. In this case, we can say that the results are reasonable. |
2019-02-28 13:26:15 -0500 | commented answer | Why cooling loads appear during the cold months ? Heating/Cooling loads using E+ Thanks a lot for your prompt response, Mr Richard Raustad In this case, we can say that the results are reasonable. |
2019-02-28 13:04:26 -0500 | marked best answer | Program exited before simulations began I am performing a simulation for a residential building with 5 thermal zones. the simulation is good but when I'm changing the construction set, the following error appears : Program Version,EnergyPlus, Version 9.0.1-bb7ca4f0da, YMD=2019.02.21 16:17, ************* Warning: Node connection errors not checked - most system input has not been read (see previous warning). ************* Fatal error -- final processing. Program exited before simulations began. See previous error messages. ************* EnergyPlus Warmup Error Summary. During Warmup: 0 Warning; 0 Severe Errors. ************* EnergyPlus Sizing Error Summary. During Sizing: 0 Warning; 0 Severe Errors. ************* EnergyPlus Terminated--Fatal Error Detected. 0 Warning; 0 Severe Errors; Elapsed Time=00hr 00min 0.19sec Any help !! Best Regard. |
2019-02-28 13:03:13 -0500 | edited question | Why cooling loads appear during the cold months ? Heating/Cooling loads using E+ Why cooling loads appear during the cold months ? Heating/Cooling loads using E+ I am simulating a residential building |
2019-02-28 13:02:53 -0500 | edited question | Why cooling loads appear during the cold months ? Heating/Cooling loads using E+ Why cooling loads appear during the cold months ? Heating/Cooling loads using E+ I am simulating a residential building |
2019-02-28 13:02:26 -0500 | edited question | Why cooling loads appear during the cold months ? Heating/Cooling loads using E+ Why cooling loads appear during the cold months ? Heating/Cooling loads using E+ I am simulating a residential building |
2019-02-28 13:01:43 -0500 | edited question | Why cooling loads appear during the cold months ? Heating/Cooling loads using E+ Why cooling loads appear during the cold months ? Heating/Cooling loads using E+ I am simulating a residential building |
2019-02-28 13:01:43 -0500 | received badge | ● Editor (source) |
2019-02-28 13:01:19 -0500 | edited question | Why cooling loads appear during the cold months ? Heating/Cooling loads using E+ Why cooling loads appear during the cold months ? Heating/Cooling loads using E+ I am simulating a residential building |
2019-02-28 13:00:50 -0500 | asked a question | Why cooling loads appear during the cold months ? Heating/Cooling loads using E+ Why cooling loads appear during the cold months ? Heating/Cooling loads using E+ I am simulation a residential building |
2019-02-28 09:58:52 -0500 | marked best answer | How can I use the Slab Preprocessor when the floor is not insulated ? Since the ground site temperature is a key factor in the simulation of residential buildings and small areas, I'm wondering if the Slab preprocessor is useful in predicting accurate GS-temperature of the non-insulated ground surfaces. And how can I use it? |
2019-02-28 09:58:52 -0500 | received badge | ● Scholar (source) |
2019-02-28 04:34:31 -0500 | commented answer | How can I use the Slab Preprocessor when the floor is not insulated ? Thanks a lot. Sincerely, |
2019-02-27 14:49:41 -0500 | commented answer | How can I use the Slab Preprocessor when the floor is not insulated ? I'm very grateful to you, sir mldichter. Thank you so much for taking your time writing this exhaustive answer. What do |
2019-02-26 18:07:46 -0500 | answered a question | How should I answer the "SLAB BOUNDARY CONDITION MODEL NAME" in the Site:GroundDomain:slab of the IDF editor in EnergyPlus? Hi, to fulfill the the slab boundary condition model name, we must first choose how the other side of the slab will be m |
2019-02-26 14:17:55 -0500 | commented answer | Program exited before simulations began Thanks for your consideration. |
2019-02-24 10:04:12 -0500 | received badge | ● Teacher (source) |
2019-02-24 06:58:41 -0500 | answered a question | Program exited before simulations began Finally, I found the solution of the problem and I would like to share it with you. Since I am French speaking, I enter |
2019-02-24 06:19:14 -0500 | asked a question | How can I use the Slab Preprocessor when the floor is not insulated ? How can I use the Slab Preprocessor when the floor is not insulated ? Since the ground site temperature is a key factor |
2019-02-23 10:34:27 -0500 | commented question | Program exited before simulations began no feedback :((((( |
2019-02-22 08:51:53 -0500 | commented question | Program exited before simulations began @AaronBoranian Please find attached the IDF file (this file is only used to estimate heating/cooling loads for a TMY in |
2019-02-22 08:51:33 -0500 | commented question | Program exited before simulations began @Moderator Please find attached the IDF file (this file is only used to estimate heating/cooling loads for a TMY in Oujd |
2019-02-22 04:01:54 -0500 | received badge | ● Supporter (source) |
2019-02-22 03:49:42 -0500 | commented question | Program exited before simulations began @AaronBoranian Please find attached the IDF file (this file is only used to estimate heating/cooling loads for a TMY in |
2019-02-21 15:14:38 -0500 | commented question | Program exited before simulations began Sir Aaron, yes i'm running the input file using EP-Launch. Sir. Mdahlhausen, the .err file contains only the message ab |
2019-02-21 15:14:21 -0500 | commented question | Program exited before simulations began Sir Aaron, yes i'm running the input file using EP-Launch. Sir. Mdahlhausen, the .err file contains only the message abo |
2019-02-21 13:09:14 -0500 | received badge | ● Student (source) |
2019-02-21 12:55:16 -0500 | asked a question | Program exited before simulations began URGENT!! Program exited before simulations began. I am performing a simulation for a residential building with 5 thermal |