Question-and-Answer Resource for the Building Energy Modeling Community
Get started with the Help page
Ask Your Question

andresgallardo's profile - activity

2023-10-04 14:35:07 -0500 marked best answer URBANopt combined project not running

I am trying to run the combined example project (combining residential and commercial workflows) with a non US epw weather file and for some reason the project doesn't run. I made sure to change the weather file names in the features .json file and in the base_workflow.osw from the mappers folder but still didn't work. I tried to run the same feature file and scenario with the default weather file (from Buffalo) and it worked so it seems like the residential feature is not finding the weather file in the weather folder? When I run the project, it creates the folders for each feature in the Run folder, but the residential feature folder is empty and the other features only have the in.osw files on them.

Any idea how can I fix this issue? Thanks in advance for your help.

2023-10-04 14:34:11 -0500 commented answer URBANopt combined project not running

This worked! Thank you so much @kflemin

2023-09-29 14:45:52 -0500 edited question URBANopt combined project not running

URBANopt combined project not running I am trying to run the combined example project (combining residential and commerc

2023-09-29 14:45:44 -0500 edited question URBANopt combined project not running

URBANopt combined project not running I am trying to run the combined example project (combining residential and commerc

2023-09-29 14:42:25 -0500 asked a question URBANopt combined project not running

URBANopt combined project not running I am trying to run the combined example project (combining residential and commerc

2023-09-19 14:59:12 -0500 commented answer EnergyPlus output files.

@michaelmichael1990 You have to add that object to your idf file, otherwise you won't find it in a "common" idf file. Us

2023-09-19 09:13:12 -0500 received badge  Rapid Responder (source)
2023-09-19 09:13:12 -0500 answered a question EnergyPlus output files.

You can use this EnergyPlus object and select "Yes" or "No" accordingly: OutputControl:Files, Yes,

2022-12-23 10:57:22 -0500 edited question Why do I keep getting an error when I try to replace my HVAC system with a DOAS with radiant slab system using the NZEHVAC openstudio measure?

Why do I keep getting an error when I try to replace my HVAC system with a DOAS with radiant slab system using the NZHVA

2022-12-23 10:56:54 -0500 asked a question Why do I keep getting an error when I try to replace my HVAC system with a DOAS with radiant slab system using the NZEHVAC openstudio measure?

Why do I keep getting an error when I try to replace my HVAC system with a DOAS with radiant slab system using the NZHVA

2022-12-23 10:54:35 -0500 asked a question Why do I keep getting an error when trying to create a DOAS with radiant slab HVAC system using the NZEHVAC openstudio measure?

Why do I keep getting an error when trying to create a DOAS with radiant slab HVAC system using the NZEHVAC openstudio m

2020-09-07 10:19:28 -0500 commented answer Open simulation output example data?

Clayton -- Sorry for the late reply. I have been trying to find a way to share the files (more than 150 GB), any suggest

2020-08-20 11:48:31 -0500 answered a question Open simulation output example data?

Are you still interested in simulation output data files? I have several output files from a shoebox type of building (C

2020-02-18 08:59:02 -0500 commented answer To model PCM hysteresis in EnergyPlus, what are the high/low temp difference of freezing/melting curves?

Thanks for taking the time to explain this. Can you be more clear, what is Exo and Endo in the graph? In the picture you

2020-02-12 09:30:16 -0500 received badge  Teacher (source)
2020-02-12 09:06:32 -0500 answered a question RDD and MDD is inactive after simulating in Energy Plus,

You have to create an object in Output:VariableDictionary class with Key Field value being IDF to make sure .rdd (Report

2020-01-28 14:20:34 -0500 received badge  Popular Question (source)
2019-11-05 10:43:15 -0500 asked a question How to interpret the outputs for CondFD Phase Change State?

How to interpret the outputs for CondFD Phase Change State? I am modeling PCM in building envelopes using eneryplus v9.0

2019-08-21 10:19:14 -0500 received badge  Enthusiast
2019-08-20 12:47:34 -0500 commented answer How to develop an EMS program to control the water flow rate of a low temperature radiant system?

@Aaron Boranian can you please help me find why my EMS program is not working as expected? I wanted to set the Water flo

2019-08-20 12:46:43 -0500 commented answer How to develop an EMS program to control the water flow rate of a low temperature radiant system?

@Aaron Boranian can you please help me find why my EMS program is not working as expected? I wanted to set the Water flo

2019-06-24 10:09:15 -0500 commented answer How to override schedules using EMS?

@shorowit thanks for your answer. I checked that link before and it helped me to modify the schedules as I wanted, but a

2019-06-17 20:54:18 -0500 asked a question How to override schedules using EMS?

How to override schedules using EMS? I want to implement a specific control strategy to control the ventilation system c

2019-05-30 10:51:40 -0500 commented answer How to develop an EMS program to control the water flow rate of a low temperature radiant system?

@Aaron Boranian I recently tried to implement what you suggested in this post but apparently there are problems with thi

2019-04-28 12:45:48 -0500 marked best answer How to develop an EMS program to control the water flow rate of a low temperature radiant system?

I am not sure if what I am trying to do is feasible and logic. I want to control a constant flow low temp radiant system based on the radiant surface temperature (in my case ceiling surface temperature). I tried to add a EMS sensor for Surface Inside Face Temperature for the Ceiling surface; for the actuator I am using "Constant Flow Low Temp Radiant” with the control type “Water Mass Flow Rate”. My problem is that I am not sure what should be the logic of my program. Basically, I want to provide chilled water only after the heat gains from a room have melted all the phase change material (PCM) in which the pipes of a radiant system are embedded. I am assuming that all the PCM is melted when the temperature of the ceiling is a couple of degrees above the melting point (around 23C). In my case, I want to run the chilled water when the surface temperature (which in the model should be the same as the PCM temperature) is above 25 C, which should be an indication that all the PCM is melted and needs to be regenerated. The chilled water is used to regenerate (solidify) the PCM by reducing its temperature to 21 C. When the temperature reaches 21 C, the chilled water stops and allows the system to work passively by absorbing internal heat gains until the surface temperature (PCM temperature) reaches 25C, when the system starts to work again.

Any suggestions???

2019-04-26 11:07:30 -0500 asked a question To model PCM hysteresis in EnergyPlus, what are the high/low temp difference of freezing/melting curves?

To model PCM hysteresis in EnergyPlus, what are the high/low temp difference of freezing/melting curves? I read the Ener

2019-04-15 12:32:40 -0500 commented answer How to develop an EMS program to control the water flow rate of a low temperature radiant system?

@luisclv @Aaron Boranian Thank you for your answers. I already implemented what @luisclv suggested and it seems to work,

2019-04-14 20:54:56 -0500 asked a question How to develop an EMS program to control the water flow rate of a low temperature radiant system?

How to develop an EMS program to control the water flow rate of a low temperature radiant system? I am not sure if what

2019-04-02 08:48:08 -0500 commented answer Desiccant Wheel with both sides in the Supply Flow

Once again thank you very much for your help!

2019-04-01 21:11:02 -0500 commented answer Desiccant Wheel with both sides in the Supply Flow

Also, what would be the appropriate selection for the last inputs of CoilSystem:Cooling:DX object, considering that I am

2019-04-01 21:09:30 -0500 commented answer Desiccant Wheel with both sides in the Supply Flow

@rraustad I wanted to ask you one last thing regarding the heat exchanger assisted cooling coil. How do I control the op

2019-04-01 21:09:30 -0500 received badge  Commentator
2019-03-27 12:20:10 -0500 commented answer Desiccant Wheel with both sides in the Supply Flow

Here is a link to the fixed idf: https://drive.google.com/file/d/1V2snovxh6Sa4KCIhHcLdMrA3OiCyqi_2/view?usp=sharing

2019-03-27 12:17:19 -0500 commented answer Desiccant Wheel with both sides in the Supply Flow

@rraustad I managed to run the file without any severe errors by implementing your last suggestion. Apparently it is wor

2019-03-27 09:12:38 -0500 commented answer Desiccant Wheel with both sides in the Supply Flow

I will try that. Thank you very much for your help.