First time here? Check out the Help page!
2023-12-12 15:42:28 -0500 | commented answer | Enthalpy Energy Recovery plus Sensible Heat Recovery for Reheat That's my issue too. DB is only on E+ 9.4 and you're limited by the functionality of that front end. I wasn't able to |
2023-12-11 10:30:26 -0500 | edited question | Enthalpy Energy Recovery plus Sensible Heat Recovery for Reheat Dual Enthalpy Wheels Can energy plus simulate AHU / DOAS units that incorporate dual enthalpy wheels or series energy re |
2023-07-19 17:47:24 -0500 | received badge | ● Commentator |
2023-07-19 17:47:24 -0500 | commented answer | Exhaust Air Heat Pumps in Equest This sounds similar to an optional energy code pathway for laboratories in MA. Large airflows 24/7. The HP condensing |
2023-06-22 10:51:46 -0500 | received badge | ● Enthusiast |
2023-06-07 12:32:35 -0500 | commented answer | Number of Cooling Towers for ASHRAE90.1 Baseline Add that to the list of things the standard committee needs to clarify in 90.1-2025... |
2023-05-11 12:05:59 -0500 | commented question | Number of Cooling Towers for ASHRAE90.1 Baseline Your highlighted pumps in red would be the condenser loop primary pumps and you should be able to add a secondary pump t |
2023-05-11 11:28:54 -0500 | commented question | Number of Cooling Towers for ASHRAE90.1 Baseline Based on that description and the diagram in the reference manual I would think you should be able to have a "primary" p |
2023-05-11 11:21:53 -0500 | commented answer | designbuilder v7 simple hvac seasonal cop has no effect Which report are you referencing? In simple mode I believe the full E+ output report (on the simulation > summary ta |
2023-05-11 11:21:14 -0500 | edited answer | designbuilder v7 simple hvac seasonal cop has no effect Circling back to answer my own question. In "Simple" HVAC mode your system efficiencies are embedded in the HVAC Templa |
2023-05-10 13:23:22 -0500 | commented answer | Number of Cooling Towers for ASHRAE90.1 Baseline I may be wrong but our current interpretation of Appendix G is in line with GBCI so we only model one tower, irrespectiv |
2023-05-09 13:05:54 -0500 | commented answer | Number of Cooling Towers for ASHRAE90.1 Baseline I've only modeled system 7 in eQUEST and am not familiar with that apparent limitation. Would love others to chime in a |
2023-05-09 12:20:49 -0500 | answered a question | designbuilder v7 simple hvac seasonal cop has no effect Circling back to answer my own question. In "Simple" HVAC mode your system efficiencies are embedded in the HVAC Templa |
2023-05-09 11:45:06 -0500 | received badge | ● Rapid Responder (source) |
2023-05-09 11:45:06 -0500 | answered a question | Number of Cooling Towers for ASHRAE90.1 Baseline PNNL would say one tower per chiller. GBCI (i.e. LEED projects) would say one tower for the entire plant. See screensh |
2023-02-14 14:55:00 -0500 | asked a question | Enthalpy Energy Recovery plus Sensible Heat Recovery for Reheat Dual Enthalpy Wheels Can energy plus simulate AHU / DOAS units that incorporate dual enthalpy wheels or series energy re |
2022-11-29 01:42:33 -0500 | asked a question | designbuilder v7 simple hvac seasonal cop has no effect designbuilder v7 simple hvac seasonal cop has no effect Working in simple HVAC mode, ideal loads, separate fan/pump powe |
2022-07-27 12:01:13 -0500 | commented question | Easy one, how do I attach my unit heater hot water coil to my hot water loop? That did it, thanks! |
2022-07-27 00:58:59 -0500 | asked a question | Easy one, how do I attach my unit heater hot water coil to my hot water loop? Easy one, how do I attach my unit heater hot water coil to my hot water loop? OS v3.2 The zone is not attached to an air |
2021-08-23 18:25:05 -0500 | received badge | ● Editor (source) |
2021-08-23 18:25:05 -0500 | edited answer | Requirements for DCV in ASHRAE 90.1 baseline model 1) 3,000 cfm is the OA threshold at the system level 2) System mapping should not change based on DCV requirements. Als |
2021-08-23 18:24:37 -0500 | answered a question | Requirements for DCV in ASHRAE 90.1 baseline model 1) 3,000 cfm is the OA threshold at the system level 2) System mapping should not change based on DCV requirements. Als |
2020-03-27 11:56:03 -0500 | commented answer | Should the ASHRAE system 8 chiller be connected to the system 7 condenser in OpenStudio? v4 CI for the restaurant or NC for the whole mall? In either case, if the mall is more than 150,000 sf and uses a gas h |
2020-03-26 14:52:36 -0500 | answered a question | Should the ASHRAE system 8 chiller be connected to the system 7 condenser in OpenStudio? Not sure why you'd be mixing those two systems for an appendix G model? As of 90.1-2013 your baseline system type depen |
2019-11-12 13:07:19 -0500 | answered a question | LEEDv4 Kitchens G3.1.1 Exception d We were contracted GBCI reviewers once upon a time and I think most reviewers would allow the baseline kitchen to be ser |
2019-07-02 09:23:17 -0500 | received badge | ● Teacher (source) |
2019-07-01 12:36:40 -0500 | answered a question | 90.1 Window to Wall Ratio Calculation - Parking Garage If this is for an appendix G analysis, the parking garage would typically be considered a separate "building area type" |
2016-08-16 12:37:00 -0500 | received badge | ● Supporter (source) |
2015-10-01 06:11:02 -0500 | received badge | ● Student (source) |
2015-09-30 18:27:39 -0500 | asked a question | Is it possible to add a process load to a water loop in Design Builder? I want DB to capture some manually entered snowmelt loads so I can minimize post processing. |
2015-01-16 16:04:26 -0500 | commented answer | Sketchup 2015 and Open Studio 1.5 I followed these steps but when I install OS, I get the following error: "Unable to locate your sketchup 2014 installation..." I don't have SU2014, I installed SU2015. What's the next step to get this to work? Nevermind. Installing OSv1.5.5 from the developers section of the site seems to have worked. (https://www.openstudio.net/developers) |