2024-03-17 08:56:06 -0500 | asked a question | System checksums (Trace700) in Openstudio System checksums (Trace700) in Openstudio One of the most useful reports in Trace700 was System checksums. Is there a |
2023-12-18 16:11:51 -0500 | received badge | ● Popular Question (source) |
2023-09-06 17:09:34 -0500 | commented question | why the ventilation load calculation results in energy plus and HAP are different? are you taking the same outdoor ventilation air flow, temperature and relative humidity? |
2023-08-16 11:29:22 -0500 | received badge | ● Rapid Responder (source) |
2023-08-16 11:29:22 -0500 | answered a question | Chiller Evaporator Cooling Rate It seems to me that there is a thermal inertia at the beginner of each day in the modeled chiller. The modeled chiller h |
2023-07-25 08:27:57 -0500 | commented answer | How to simulated Ground tempertures? Thanks Josep. Voy a probarlos. |
2023-07-03 19:00:25 -0500 | asked a question | How to simulated Ground tempertures? How to simulated Ground tempertures? Hi. I have been reading lots of posts on how to simulate correctly ground temperat |
2023-03-14 18:05:51 -0500 | answered a question | Mall entrance infiltration modeling for LEED compliance Hi. The infiltration must be the same in the baseline and proposed model. Try to calculate a sensible infiltration air |
2023-03-14 18:05:51 -0500 | received badge | ● Rapid Responder (source) |
2023-01-31 08:16:20 -0500 | answered a question | indoor temperature does not decrease after adding insulation I could be that you have a high infiltration rate so adding insulation will not make a big difference in inside temperat |
2022-12-12 08:05:29 -0500 | received badge | ● Rapid Responder (source) |
2022-12-12 08:05:29 -0500 | answered a question | after installation of open studio where i can find icon of open studio there is no desktop shortcut shown after installation you also have to down load openstudio Application 1.5.0 https://github.com/openstudiocoalition/OpenStudioApplication/re |
2022-11-30 13:28:05 -0500 | commented question | LEED - Outdoor air flow cycled Hi Irebello I haven´t done energy simulation for LEED for a while so some things maybe different now. as far as I rem |
2022-11-30 13:26:48 -0500 | commented question | LEED - Outdoor air flow cycled Hi Irebello I haven´t done energy simulation for LEED for a while so some things maybe different now. as far as I rem |
2022-11-28 10:57:31 -0500 | answered a question | LEED - Outdoor air flow cycled Basically the reviewer is checking that the proposed model has the same outdoor air flow. The process to check it depend |
2022-10-23 10:50:01 -0500 | commented answer | What OpenStudio measure will create an EnergyPlus Zone Component Load Summary Report I tried to do the same a few years ago but I couldn't achieve it: Component Sizing Summary Report |
2022-10-23 10:49:32 -0500 | commented answer | What OpenStudio measure will create an EnergyPlus Zone Component Load Summary Report I tried to do the same a few years ago but I couldn't achieve it: link text |
2022-10-23 10:48:16 -0500 | commented answer | What OpenStudio measure will create an EnergyPlus Zone Component Load Summary Report I tried to do the same a few years ago: link text |
2022-09-24 19:45:04 -0500 | asked a question | Chiller cooling capacity sizing Chiller cooling capacity sizing I am sizing a chiller for a project. I did the model using openstudio. I ran the simula |
2022-08-22 18:12:03 -0500 | commented answer | Unreasonable "Sizing Runs" requirement in ASHRAE 90.1-2019 How do you set up HVAC ON through the whole day in openstudio? I am setting the cooling setpoint at the design temperatu |
2022-07-22 10:19:33 -0500 | asked a question | invalid stoi argument error invalid stoi argument error The error: Severe * invalid stoi argument* was obtained. EnergyPlusV22-1-0 was used to ran |
2022-07-22 08:32:33 -0500 | received badge | ● Popular Question (source) |
2022-06-23 17:22:04 -0500 | received badge | ● Rapid Responder (source) |
2022-06-23 17:22:04 -0500 | answered a question | Design considerations for a multifamily building (LEED Gold) All the consideration that you are listing are valid, however, it is more important to analyze the project with the weat |
2022-06-07 10:13:38 -0500 | answered a question | Thermal Load too low in the OpenStudio / EnergyPlus I still have differences in the cooling loads. Usually, the ground cools down the space a lot so I prefer to use adiabat |
2022-04-12 11:50:05 -0500 | commented question | How to model perimeter and interior zones I think the option C represents better the reality of the building. Since there are not real partitions in the building |
2022-03-17 14:50:09 -0500 | commented question | Blank reports Openstudio 3.1.0 if you open you file using sketchup and then launch Openstudio from there you wont have the visualisation problem. I don |
2022-03-17 14:03:39 -0500 | received badge | ● Popular Question (source) |
2022-02-22 15:15:17 -0500 | asked a question | Constant vs variable flow - Condensation loop Constant vs variable flow - Condensation loop A potential customer has a core & shell building with packaged water s |
2022-01-23 19:30:07 -0500 | answered a question | 3d animation of E+ results Grasshoper and ladybug tools. https://www.ladybug.tools/ |
2022-01-23 19:30:07 -0500 | received badge | ● Rapid Responder (source) |
2022-01-20 07:11:46 -0500 | commented question | Peak loads - model vs design calculation comparison In my experience when doing equipment sizing there are too many safety factors that at the end gives you an oversize coo |
2022-01-13 16:29:21 -0500 | received badge | ● Rapid Responder (source) |
2022-01-13 16:29:21 -0500 | answered a question | EnergyPlus freezes during simulation for a specific orientation I imported your IDF file to Openstudio and something is wrong with the walls. After runing the model I got this error: M |
2022-01-11 15:33:17 -0500 | commented question | opaque surface construction; it should have a window construction I think you can find some light in this post link text |
2022-01-11 15:13:20 -0500 | commented question | opaque surface construction; it should have a window construction There is not screenshot attached. |
2021-12-27 10:51:07 -0500 | commented question | first floor disconnected from 2nd floor I have tried to export gbXML from Revit to Openstudio a few years ago. In my experience the process is not 100% bug free |
2021-11-24 13:05:49 -0500 | commented answer | PTAC with electric cooling Electric cooling could be anything |
2021-11-23 13:55:46 -0500 | answered a question | PTAC with electric cooling In the HVAC system tab on the right- Library-PTAC- PTAC DX Clg Elec Htg componet |
2021-11-18 13:33:52 -0500 | commented answer | Natural Ventilation in OpenStudio The effective angle is the angle between the north and the normal of the wall where the opening is located. |
2021-11-17 08:34:35 -0500 | answered a question | Natural Ventilation in OpenStudio you can try in the thermal zone tab/Zone ventilation Wind and Open Area. You can input the opening area, Opening orient |
2021-11-17 08:34:35 -0500 | received badge | ● Rapid Responder (source) |
2021-11-03 18:51:39 -0500 | commented question | Indoor relative humidity reaches 100% when windows are closed I usually input 120W /Person not 120W/m2 |
2021-10-25 11:56:43 -0500 | commented question | reference plane of wall construction with differnet wall thickness I you can attache a pic it will be easy to understand de walls. |
2021-10-07 14:46:33 -0500 | commented answer | Cooling coil sizing difference Thanks. Have you compared your Trace 3D plus results with other software (Trace700)? |
2021-10-07 14:43:04 -0500 | commented answer | Cooling coil sizing difference Thanks for your reply. By the way I have seen your videos in your youtube channel. Do you have a work flow to calculate |
2021-10-05 15:03:35 -0500 | answered a question | Heating and Cooling load components: a detailed breakdown Hi. You can use ladybug tools. link text The work flow is a bit different but you can get the results that you are loo |
2021-10-03 09:48:33 -0500 | commented question | Why is E+ auto-sizing, oversizing the DX cooling coil? Have you found an answer? |
2021-10-02 21:17:24 -0500 | edited answer | Load vs Demand vs Consumption [ESL question] Hi. I am quite sure that heating load doesn't take in to account people or plug loads. Heating load is used to size the |
2021-10-02 21:17:06 -0500 | edited answer | Load vs Demand vs Consumption [ESL question] Hi. I am quite sure that heating load doesn't take in to account people or plug loads. Heating load is used to size the |