First time here? Check out the Help page!
2021-11-22 08:03:51 -0500 | commented question | How to Change Inlet Air Flows Meanwhile the Simulation is Running Thanks for letting me notice this. I've updated my post as you suggested. |
2021-11-22 04:36:57 -0500 | received badge | ● Organizer (source) |
2021-11-22 04:35:01 -0500 | edited question | How to Change Inlet Air Flows Meanwhile the Simulation is Running How to Change Inlet Air Flows Meanwhile the Simulation is Running Hello, I'm trying to understand whether is possible o |
2021-11-22 04:32:59 -0500 | edited question | How to Change Inlet Air Flows Meanwhile the Simulation is Running How to Change Inlet Air Flows Meanwhile the Simulation is Running Hello, I'm trying to understand whether is possible o |
2021-11-22 04:28:53 -0500 | edited question | How to Change Inlet Air Flows Meanwhile the Simulation is Running How to Change Inlet Air Flows Meanwhile the Simulation is Running Hello, I'm trying to understand whether is possible o |
2021-11-19 02:38:19 -0500 | asked a question | How to Change Inlet Air Flows Meanwhile the Simulation is Running How to Change Inlet Air Flows Meanwhile the Simulation is Running Hello, I'm trying to understand whether is possible o |
2021-09-23 03:24:11 -0500 | edited question | How to control back-up equipments based on a defined ΔT from the setpoint temp How to control back-up equipments based on a defined ΔT from the setpoint temp Hello Everyone, I finished modeling the |
2021-09-23 03:24:11 -0500 | received badge | ● Editor (source) |
2021-09-23 02:45:37 -0500 | asked a question | How to control back-up equipments based on a defined ΔT from the setpoint temp How to control back-up equipments based on a defined ΔT from the setpoint temp Hello Everyone, I finished modeling the |
2021-07-14 10:08:03 -0500 | received badge | ● Rapid Responder |
2021-07-14 10:08:03 -0500 | answered a question | Generator Coolant Outlet Temperature | Generator Coolant Inlet Temperature That's what I thought. Many thanks for your reply. |
2021-07-14 02:52:13 -0500 | asked a question | Generator Coolant Outlet Temperature | Generator Coolant Inlet Temperature Generator Coolant Outlet Temperature | Generator Coolant Inlet Temperature Hello, Is there any way to request both Gen |
2021-04-15 06:37:47 -0500 | commented question | Subdivide huge energyplus models into several files Hi Macumber, many thanks for your reply. That could be a good starting point. At the very end I can solve the surface ma |
2021-03-29 04:52:25 -0500 | commented question | Subdivide huge energyplus models into several files Well... I do work for a Company that uses calibrated energy models for optimizing indoor setpoint temperatures in real-t |
2021-03-28 15:41:03 -0500 | commented question | Subdivide huge energyplus models into several files Unfortunately, those that you mentioned are not options as I need to have direct control on the specific thermal zone. |
2021-03-26 11:12:54 -0500 | asked a question | Subdivide huge energyplus models into several files Subdivide huge energyplus models into several files Hello to everyone, I'm modeling a skyscraper using OpenStudio 3.1. |
2021-01-20 05:26:40 -0500 | received badge | ● Supporter (source) |
2021-01-20 05:25:19 -0500 | answered a question | Thermal Zones that are open to the outdoor environment Yes, that was the other option. I just wanted to have a bit more control over that space. But, at the moment, I think it |
2021-01-14 03:43:02 -0500 | asked a question | Thermal Zones that are open to the outdoor environment Thermal Zones that are open to the outdoor environment Hi, I am currently modeling an University building and the Atri |
2020-11-12 13:24:12 -0500 | asked a question | CO2 concentration control and natural ventilation CO2 concentration control and natural ventilation Hello, I am trying to model windows opening having as a EMS Sensor the |
2019-02-20 03:24:47 -0500 | marked best answer | Heat Pump - Water to Water - Cooling Does Not Link to the Condenser Loop I'm modeling a cold water loop with OpenStudio 2.7. The loop has three water to water heat pumps on the supply side. The problem that I am facing is that the heat pump objects do not link to any condenser loop. I also tried to both substitute the object with chillers and to reduce the number of objects to one, but the problem still remains. Any idea on how to solve it? |
2019-02-20 03:24:47 -0500 | received badge | ● Scholar (source) |
2019-02-17 11:21:18 -0500 | received badge | ● Student (source) |
2019-02-15 12:20:08 -0500 | asked a question | Heat Pump - Water to Water - Cooling Does Not Link to the Condenser Loop Heat Pump - Water to Water - Cooling Does Not Link to the Condenser Loop I'm modeling a cold water loop with OpenStudio |