2023-12-05 09:18:00 -0500 | commented answer | Heat pipe system OpenStudio I also think it could be an option. Although I am concerned about the heat exchange between the warm outside air and the |
2023-12-05 08:40:04 -0500 | commented answer | Heat pipe system OpenStudio Thank you for your answer. Do you think there might be a way to simplify the system? Maybe use Coil:heating/cooling:DX a |
2023-12-05 08:36:50 -0500 | marked best answer | Heat pipe system OpenStudio Hi! I'm modelling an AHU (Air Handling Unit) which has a system called "heat pipe" as you can see in the picture below. C:\fakepath\Esquema clima .png I've been looking for information on how to model this type of system but haven't found anything. Any ideas? I've seen that in EnergyPlus there is the object: CoilSystem:CoolingWater:HeatExchangerAssiste, which works similarly but i haven't found it in OpenStudio. Thanks :) |
2023-12-05 04:46:04 -0500 | asked a question | Heat pipe system OpenStudio Heat pipe system OpenStudio Hi! I'm modelling an AHU (Air Handling Unit) which has a system called "heat pipe" as you c |
2023-09-18 04:55:39 -0500 | commented question | why the ventilation load calculation results in energy plus and HAP are different? Are you ussing schedules for ventilation? I recently also had to compare a HAP model with an EP model and I realized tha |
2023-09-15 13:36:08 -0500 | commented question | Sensible Heat Gain Summary Hourly Hi showowit, Thank you for your response. I'm going to provide some more context: I need to demonstrate with my energy |
2023-09-15 13:34:41 -0500 | commented question | Sensible Heat Gain Summary Hourly However, in the table, it shows 23 kW. So, I suspect that I also need to use the outputs indicated in the documentation |
2023-09-15 13:33:16 -0500 | commented question | Sensible Heat Gain Summary Hourly To do this, I am using the output:variable "Zone Ideal Loads Zone Sensible Heating Rate." The maximum value for the enti |
2023-09-15 13:30:16 -0500 | commented question | Sensible Heat Gain Summary Hourly Hi showowit, Thank you for your response. I'm going to provide some more context: I need to demonstrate with my energy |
2023-09-15 05:28:49 -0500 | edited question | Sensible Heat Gain Summary Hourly Sensible Heat Gain Summary Hourly Hi All, I'm conducting a study on the heating and cooling demand of a building, and I |
2023-09-15 03:03:22 -0500 | asked a question | Sensible Heat Gain Summary Hourly Sensible Heat Gain Summary Hourly Hi All, I'm conducting a study on the heating and cooling demand of a building, and I |
2023-04-20 05:04:11 -0500 | asked a question | Natural and artificial lighting [lux] Natural and artificial lighting [lux] Hi! I'm working on an outdoor lighting project. Previously, I've worked on other |
2022-12-23 07:04:28 -0500 | answered a question | ı m new and ı try to use Jeplus. ın result table(csv) ı can not see the outputs. Hi Merve, Check this: https://unmethours.com/question/76433/how-to-obtain-hourly-mean-air-temperature/#76488 It's impo |
2022-08-05 05:23:00 -0500 | commented answer | Sensitivity Analysis result not available with a larger sample size If you're sure you have defined the output variables correctly in jEplus I can't help you. I'm still learning how to us |
2022-08-05 02:41:59 -0500 | commented answer | Sensitivity Analysis result not available with a larger sample size Have you configured: "algorithm settings" to do the sensitivity analysis? |
2022-08-04 01:49:30 -0500 | received badge | ● Rapid Responder (source) |
2022-08-04 01:49:30 -0500 | answered a question | Sensitivity Analysis result not available with a larger sample size Hi Julgam, Are you using jEPlus+EA? I've been simulated this days and I've had a similar problem (I think). If you ge |
2022-07-05 03:47:02 -0500 | received badge | ● Teacher (source) |
2022-07-05 03:19:44 -0500 | answered a question | How to obtain hourly mean air temperature? Hi! I had the same problem a few weeks ago. -Result Collection -RVIs (New object) -Edit RVIs and write: eplusout.eso e |
2022-06-08 06:25:58 -0500 | marked best answer | WaterHeater:Mixed as a hot water storage I have a system that produces hot water with a heat pump. Now I want to add a hot water tank to soften the peaks in demand. I'm using: WaterHeater:Mixed with 0W but I don't understand the difference between "Use side inlet node name" and "Source side inlet node name". |
2022-06-08 06:25:38 -0500 | marked best answer | Air-Water heat pump in EnergyPlus? Hi!, I'm simulating a building that uses an air-water heat-pump to produce hot water. The Fan-coil and UTAs use hot water but is impossible to associate my heat pump with these systems. The solution I have found is to use a boiler with efficiency 1 and calculate the real consumption using the COP of the heat pump. The problem is that I need use Jeplus to calibrate the COP but its not an input variable. Is there a way to define a hot water production system to which I can introduce the COP of my heat pump? Thank you! |
2022-06-08 06:25:38 -0500 | received badge | ● Scholar (source) |
2022-06-06 05:19:52 -0500 | asked a question | WaterHeater:Mixed as a hot water storage WaterHeater:Mixed as a hot water storage I have a system that produces hot water with a heat pump. Now I want to add a h |
2022-05-27 06:02:16 -0500 | edited question | HeatPump:PlantLoop:EIR:Heating HeatPump:PlantLoop:EIR:Heating I have an air-water heat pump. Produces hot water at a maximum temperature of 50ºC. In " |
2022-05-27 06:02:16 -0500 | received badge | ● Editor (source) |
2022-05-27 06:00:46 -0500 | asked a question | HeatPump:PlantLoop:EIR:Heating HeatPump:PlantLoop:EIR:Heating I have an air-water heat pump. Produces hot water at a maximum temperature of 50ºC. In " |
2022-05-23 05:24:58 -0500 | commented question | HeatPumpPlantLoopEIRHeating Not Heating I have the same probem. I´m working with a boiler and I want to replace it with an air-water heat pump. I´m using HeatP |
2022-05-23 03:41:34 -0500 | received badge | ● Supporter (source) |
2022-05-18 14:01:28 -0500 | received badge | ● Student (source) |
2022-05-18 09:35:11 -0500 | asked a question | Air-Water heat pump in EnergyPlus? Air-Water heat pump in EnergyPlus? Hi!, I'm simulating a building that uses an air-water heat-pump to produce hot water |