2023-12-05 09:18:00 -0500 commented answer Heat pipe system OpenStudio

I also think it could be an option. Although I am concerned about the heat exchange between the warm outside air and the

2023-12-05 08:40:04 -0500 commented answer Heat pipe system OpenStudio

Thank you for your answer. Do you think there might be a way to simplify the system? Maybe use Coil:heating/cooling:DX a

2023-12-05 08:36:50 -0500 marked best answer Heat pipe system OpenStudio

Hi!

I'm modelling an AHU (Air Handling Unit) which has a system called "heat pipe" as you can see in the picture below.

C:\fakepath\Esquema clima .png

I've been looking for information on how to model this type of system but haven't found anything. Any ideas?

I've seen that in EnergyPlus there is the object: CoilSystem:CoolingWater:HeatExchangerAssiste, which works similarly but i haven't found it in OpenStudio.

Thanks :)

2023-12-05 04:46:04 -0500 asked a question Heat pipe system OpenStudio

Heat pipe system OpenStudio Hi! I'm modelling an AHU (Air Handling Unit) which has a system called "heat pipe" as you c

2023-09-18 04:55:39 -0500 commented question why the ventilation load calculation results in energy plus and HAP are different?

Are you ussing schedules for ventilation? I recently also had to compare a HAP model with an EP model and I realized tha

2023-09-15 13:36:08 -0500 commented question Sensible Heat Gain Summary Hourly

Hi showowit, Thank you for your response. I'm going to provide some more context: I need to demonstrate with my energy

2023-09-15 13:34:41 -0500 commented question Sensible Heat Gain Summary Hourly

However, in the table, it shows 23 kW. So, I suspect that I also need to use the outputs indicated in the documentation

2023-09-15 13:33:16 -0500 commented question Sensible Heat Gain Summary Hourly

To do this, I am using the output:variable "Zone Ideal Loads Zone Sensible Heating Rate." The maximum value for the enti

2023-09-15 13:30:16 -0500 commented question Sensible Heat Gain Summary Hourly

Hi showowit, Thank you for your response. I'm going to provide some more context: I need to demonstrate with my energy

2023-09-15 05:28:49 -0500 edited question Sensible Heat Gain Summary Hourly

Sensible Heat Gain Summary Hourly Hi All, I'm conducting a study on the heating and cooling demand of a building, and I

2023-09-15 03:03:22 -0500 asked a question Sensible Heat Gain Summary Hourly

Sensible Heat Gain Summary Hourly Hi All, I'm conducting a study on the heating and cooling demand of a building, and I

2023-04-20 05:04:11 -0500 asked a question Natural and artificial lighting [lux]

Natural and artificial lighting [lux] Hi! I'm working on an outdoor lighting project. Previously, I've worked on other

2022-12-23 07:04:28 -0500 answered a question ı m new and ı try to use Jeplus. ın result table(csv) ı can not see the outputs.

Hi Merve, Check this: https://unmethours.com/question/76433/how-to-obtain-hourly-mean-air-temperature/#76488 It's impo

2022-08-05 05:23:00 -0500 commented answer Sensitivity Analysis result not available with a larger sample size

If you're sure you have defined the output variables correctly in jEplus I can't help you. I'm still learning how to us

2022-08-05 02:41:59 -0500 commented answer Sensitivity Analysis result not available with a larger sample size

Have you configured: "algorithm settings" to do the sensitivity analysis?

2022-08-04 01:49:30 -0500 received badge  Rapid Responder (source)
2022-08-04 01:49:30 -0500 answered a question Sensitivity Analysis result not available with a larger sample size

Hi Julgam, Are you using jEPlus+EA? I've been simulated this days and I've had a similar problem (I think). If you ge

2022-07-05 03:47:02 -0500 received badge  Teacher (source)
2022-07-05 03:19:44 -0500 answered a question How to obtain hourly mean air temperature?

Hi! I had the same problem a few weeks ago. -Result Collection -RVIs (New object) -Edit RVIs and write: eplusout.eso e

2022-06-08 06:25:58 -0500 marked best answer WaterHeater:Mixed as a hot water storage

I have a system that produces hot water with a heat pump. Now I want to add a hot water tank to soften the peaks in demand.

I'm using: WaterHeater:Mixed with 0W but I don't understand the difference between "Use side inlet node name" and "Source side inlet node name".

2022-06-08 06:25:38 -0500 marked best answer Air-Water heat pump in EnergyPlus?

Hi!,

I'm simulating a building that uses an air-water heat-pump to produce hot water. The Fan-coil and UTAs use hot water but is impossible to associate my heat pump with these systems.

The solution I have found is to use a boiler with efficiency 1 and calculate the real consumption using the COP of the heat pump.

The problem is that I need use Jeplus to calibrate the COP but its not an input variable.

Is there a way to define a hot water production system to which I can introduce the COP of my heat pump?

Thank you!

2022-06-08 06:25:38 -0500 received badge  Scholar (source)
2022-06-06 05:19:52 -0500 asked a question WaterHeater:Mixed as a hot water storage

WaterHeater:Mixed as a hot water storage I have a system that produces hot water with a heat pump. Now I want to add a h

2022-05-27 06:02:16 -0500 edited question HeatPump:PlantLoop:EIR:Heating

HeatPump:PlantLoop:EIR:Heating I have an air-water heat pump. Produces hot water at a maximum temperature of 50ºC. In "

2022-05-27 06:02:16 -0500 received badge  Editor (source)
2022-05-27 06:00:46 -0500 asked a question HeatPump:PlantLoop:EIR:Heating

HeatPump:PlantLoop:EIR:Heating I have an air-water heat pump. Produces hot water at a maximum temperature of 50ºC. In "

2022-05-23 05:24:58 -0500 commented question HeatPumpPlantLoopEIRHeating Not Heating

I have the same probem. I´m working with a boiler and I want to replace it with an air-water heat pump. I´m using HeatP

2022-05-23 03:41:34 -0500 received badge  Supporter (source)
2022-05-18 14:01:28 -0500 received badge  Student (source)
2022-05-18 09:35:11 -0500 asked a question Air-Water heat pump in EnergyPlus?

Air-Water heat pump in EnergyPlus? Hi!, I'm simulating a building that uses an air-water heat-pump to produce hot water