2020-09-04 13:53:13 -0500 received badge  Self-Learner (source)
2019-05-27 15:25:47 -0500 received badge  Teacher (source)
2019-05-25 18:04:27 -0500 marked best answer ASHRAE 55 Adaptive model temperature loss some months

Hi all, i am using adaptive model ASHRAE 55 in EnergyPlus to evaluate thermal comfort in a free-running building. However, with some weather files, the output:variable did not showed adaptive model temperatures of some months, so the thermal comfort status showed the value of -1 which means not applicable. Please see the attached image.

I tried many weather files from EnergyPlus database. Some were ok but some were not, for instance most cases in Southern China where my building locates could not calculate adaptive model temperatures for January and December. Any thought? Thanks.image description

2019-05-25 18:04:16 -0500 answered a question ASHRAE 55 Adaptive model temperature loss some months

I found the answer in Engineering Reference and ASHRAE 55 standard: If monthly outdoor temperature is less than 10°(C)

2019-05-25 17:47:01 -0500 edited question ASHRAE 55 Adaptive model temperature loss some months

ASHRAE 55 Adaptive model temperature loss some months Hi all, i am using adaptive model ASHRAE 55 in EnergyPlus to evalu

2019-05-25 17:46:47 -0500 edited question ASHRAE 55 Adaptive model temperature loss some months

ASHRAE 55-2004 Adaptive model temperature loss some months Hi all, i am using adaptive model ASHRAE 55-2004 in EnergyPlu

2019-05-24 19:47:18 -0500 asked a question ASHRAE 55 Adaptive model temperature loss some months

ASHRAE 55-2004 Adaptive model temperature loss some months Hi all, i am using adaptive model ASHRAE 55-2004 in EnergyPlu

2019-02-09 10:29:02 -0500 commented question ** Severe ** Sizing:Zone Name, duplicate name=AMENITIES

From InputOutputReference: "Users need to remember that no objects related to HVAC except for HVAC template objects are

2018-09-04 09:29:01 -0500 marked best answer Cannot run EnergyPlus simulation in Euclid

Hi all. I can not run EnergyPlus simulation from Euclid extension for Sketch Up. When i press the "Run" button in "Run simulation" window in Sketchup , a DOS screen "C:\WINDOWS\system32\cmd.exe" appears without any content, followed by the appearance of EP-Launch of previous simulation. That's it. The IDF file run well in EP-Launch directly. Can you help me please? Thanks! I am using Euclid 0.9.3, Energy Plus 8.7 and Sketch Up 2016 in Win 10.

edit: thanks Admin, i can upload an illustrative image now. image description

2018-09-04 09:29:01 -0500 received badge  Scholar (source)
2018-09-04 09:28:37 -0500 commented answer Cannot run EnergyPlus simulation in Euclid

Great! Your answer is exactly what happen in my case. Thank you very much Peter.

2018-09-04 09:23:41 -0500 received badge  Supporter (source)
2018-08-25 11:57:31 -0500 received badge  Editor (source)
2018-08-25 11:57:31 -0500 edited question Cannot run EnergyPlus simulation in Euclid

Cannot run EnergyPlus simulation in Euclid Hi all. I can not run EnergyPlus simulation from Euclid extension for Sketch

2018-08-25 11:53:13 -0500 edited question Cannot run EnergyPlus simulation in Euclid

Cannot run EnergyPlus simulation in Euclid Hi all. I can not run EnergyPlus simulation from Euclid extension for Sketch

2018-08-25 11:00:47 -0500 received badge  Student (source)
2018-08-24 17:50:16 -0500 asked a question Cannot run EnergyPlus simulation in Euclid

Cannot run EnergyPlus simulation in Euclid Hi all. I can not run EnergyPlus simulation from Euclid extension for Sketch