2022-02-04 11:26:46 -0500 | marked best answer | Cant add daylighting control Hello, I am working on Euclid. I would like to add a daylighting control for one of my zone but I cant. The bottom to add the daylighting control is grey. For the illuminance map, no problem. How can I fix it ? |
2020-10-01 10:57:42 -0500 | received badge | ● Popular Question (source) |
2019-12-28 09:40:14 -0500 | commented question | Zone cross mixing in energyplus I don't have the answer but I have a quick question. How do you determine / calculate the design flow rate in this case |
2019-09-28 01:30:00 -0500 | commented answer | Energyplus, Design day : date and solar radiation Thank you very much for your answer, a lot of information. However, I didnt undertand everything. So in summary, do you |
2019-09-26 19:52:37 -0500 | commented answer | Energyplus, Design day : date and solar radiation Thank you for your answer but my question is more about the solar radiation and the design day. Because here in my case, |
2019-09-26 02:00:01 -0500 | asked a question | Energyplus, Design day : date and solar radiation Energyplus, Design day : date and solar radiation Hello everyone, I am working currently on a hotel project with rooms |
2019-08-29 00:11:29 -0500 | received badge | ● Teacher (source) |
2019-08-28 22:47:21 -0500 | answered a question | visualize EnergyPlus schedules In energy plus, you need to create an object in the tab "output:SQ Lite" and in the tab "output:variable", look for the |
2019-04-18 22:27:25 -0500 | commented answer | VRF templates : How to fix these error: "Gross Rated Total Cooling Capacity [W] will be limited by the maximum rated volume flow per rated total capacity ratio" I uploaded and edited my results. So when I decrease my supply air temperature, my flow rate decreases. The cooling cap |
2019-04-18 21:32:38 -0500 | edited question | VRF templates : How to fix these error: "Gross Rated Total Cooling Capacity [W] will be limited by the maximum rated volume flow per rated total capacity ratio" VRF templates : How to fix these error: "Gross Rated Total Cooling Capacity [W] will be limited by the maximum rated vol |
2019-04-18 08:37:10 -0500 | commented answer | VRF templates : How to fix these error: "Gross Rated Total Cooling Capacity [W] will be limited by the maximum rated volume flow per rated total capacity ratio" For this project, I dont have any heating. I am in indonesia, hot climate. Only cooling, for all the year |
2019-04-18 02:59:44 -0500 | commented answer | VRF templates : How to fix these error: "Gross Rated Total Cooling Capacity [W] will be limited by the maximum rated volume flow per rated total capacity ratio" FI, when I raise the supply air temperature, my requested flow ratio diverge from the limit. Choosing a "random tempera |
2019-04-17 03:03:09 -0500 | commented answer | VRF templates : How to fix these error: "Gross Rated Total Cooling Capacity [W] will be limited by the maximum rated volume flow per rated total capacity ratio" I tried, [lease Check above my screenshot. But I don't really know how to read and understand the results. Which one I n |
2019-04-17 02:52:00 -0500 | edited question | VRF templates : How to fix these error: "Gross Rated Total Cooling Capacity [W] will be limited by the maximum rated volume flow per rated total capacity ratio" VRF templates : How to fix these error: "Gross Rated Total Cooling Capacity [W] will be limited by the maximum rated vol |
2019-04-17 02:51:17 -0500 | edited question | VRF templates : How to fix these error: "Gross Rated Total Cooling Capacity [W] will be limited by the maximum rated volume flow per rated total capacity ratio" VRF templates : How to fix these error: "Gross Rated Total Cooling Capacity [W] will be limited by the maximum rated vol |
2019-04-10 08:20:04 -0500 | edited question | VRF templates : How to fix these error: "Gross Rated Total Cooling Capacity [W] will be limited by the maximum rated volume flow per rated total capacity ratio" How to fix these error: "Gross Rated Total Cooling Capacity [W] will be limited by the maximum rated volume flow per rat |
2019-04-09 21:15:04 -0500 | commented answer | VRF templates : How to fix these error: "Gross Rated Total Cooling Capacity [W] will be limited by the maximum rated volume flow per rated total capacity ratio" Thank for the answer. I tried but I still have these warnings. For info, the difference between the 'Requested capacity |
2019-04-05 05:28:57 -0500 | commented question | VRF templates : How to fix these error: "Gross Rated Total Cooling Capacity [W] will be limited by the maximum rated volume flow per rated total capacity ratio" Does anyone have an answer or a lead for this issue ? I am facing the same issue with the VRF templates and autosize for |
2019-04-05 02:19:26 -0500 | edited question | VRF templates : How to fix these error: "Gross Rated Total Cooling Capacity [W] will be limited by the maximum rated volume flow per rated total capacity ratio" How to fix these error: "Gross Rated Total Cooling Capacity [W] will be limited by the maximum rated volume flow per rat |
2019-02-01 14:25:40 -0500 | marked best answer | OS: VRFwithDOAS failed Hi all, I am trying to design DOAS system to my existing VRF system in OS. I have successfully designed the VRF system (1 terminal 1 thermal zone). Would like to put 5.5 l/s/person precooled outdoor intake to the room, and found out that designing the air loop coupled with VRF in OS is not easy, I tried to use the measure in BCL "VRFwithDOAS". My model is simple 1 thermal zone building. And never ran successfully. Always show this message: It says the error is "Null reference for setZoneforMasterThermostatLocation", but i couldn't find any clue where to input it in the VRFwithDOAS measure, anyone can help me with this? |
2019-01-20 22:25:38 -0500 | answered a question | why are there many lines in result graph even i have only two thermal zone? In your video, at 50 seconds, you have imported and defined 7 design days. Every curves represent 1 design days. Check |
2019-01-18 08:34:53 -0500 | commented answer | E+, defining DOAS fan specifications according to manufacturer's book Thank you for your answer. If I understand well, the electric rated power should be equal to the fan power of the manufa |
2019-01-18 03:04:13 -0500 | edited question | E+, defining DOAS fan specifications according to manufacturer's book E+, defining DOAS fan specification according to manufacturer's book I am a beginner with E+ Now, I trying to simulate |
2019-01-17 04:43:06 -0500 | asked a question | E+, part load ratio and VRF E+, part load ratio and VRF I am trying to get my part load ratio related to the number of hours. A certification audito |
2019-01-14 18:47:56 -0500 | commented question | E+, defining DOAS fan specifications according to manufacturer's book I read this post and its what I did. Input the total static pressure in the field "supply fan delta pressure". But it gi |
2019-01-13 19:46:02 -0500 | edited question | E+, defining DOAS fan specifications according to manufacturer's book E+, defining DOAS fan specification according to manufacturer's book I am a beginner with E+ Now, I trying to simulate |
2019-01-10 21:36:35 -0500 | commented question | E+, defining DOAS fan specifications according to manufacturer's book I don't expect to be exactly the same but close at least. The "rated electric power" should be more or less than "fan mo |
2019-01-10 21:18:39 -0500 | edited question | E+, defining DOAS fan specifications according to manufacturer's book E+, defining DOAS fan specification according to manufacturer's book I try to simulate and represent a DOAS according to |
2019-01-10 19:20:22 -0500 | commented question | E+, defining DOAS fan specifications according to manufacturer's book I dont expect to be exactly the same but close at least. I have some doubt about the pressure, the "supply fan delta pre |
2019-01-10 00:15:36 -0500 | edited question | E+, defining DOAS fan specifications according to manufacturer's book E+, defining DOAS fan specification according to manufacturer's book I try to simulate and represent a DOAS according to |
2019-01-10 00:12:45 -0500 | edited question | E+, defining DOAS fan specifications according to manufacturer's book E+,defining DOAS fan specification according to manufacturer's book I try to simulate and represent a DOAS according to |
2019-01-10 00:12:34 -0500 | asked a question | E+, defining DOAS fan specifications according to manufacturer's book E+,defining DOAS fan specification according to manufacturer's book I try to simulate and represent a DOAS according to |
2019-01-03 00:24:57 -0500 | edited question | AC hard sized, number of people and variation of the inside temperature AC hard sized, number of people and variation of the inside temperature I did a auto size simulation in the purpose to f |
2018-12-10 00:53:05 -0500 | edited question | AC hard sized, number of people and variation of the inside temperature AC hard sized, number of people and variation of the inside temperature I did a auto size simulation in the purpose to f |
2018-12-06 08:50:34 -0500 | edited question | AC hard sized, number of people and variation of the inside temperature AC hard sized, number of people and variation of the inside temperature I did a auto size simulation in the purpose to f |
2018-12-03 20:51:05 -0500 | edited question | AC hard sized, number of people and variation of the inside temperature AC hard sized, number of people and variation of the inside temperature I did a auto size simulation in the purpose to f |
2018-11-30 07:13:13 -0500 | edited question | AC hard sized, number of people and variation of the inside temperature AC hard sized, number of people and variation of the inside temperature I did a auto size simulation in the purpose to f |
2018-11-30 01:59:36 -0500 | commented answer | How to modeling the ceiling void ? Its an old conversation but I try. If the ceiling void is 20/30/40 cm, we set an air gap of 20/30/40 cm ? So it means wi |
2018-11-28 19:53:33 -0500 | commented question | AC hard sized, number of people and variation of the inside temperature I did this test for the sizing day to easily compare the results. I work with a VRF system and a DOAS with HX for the fr |
2018-11-27 09:02:09 -0500 | edited question | AC hard sized, number of people and variation of the inside temperature Hard sizing AC and inside temperature I did a auto size simulation in the purpose to find the cooling capacity of every |
2018-11-26 20:18:21 -0500 | edited question | AC hard sized, number of people and variation of the inside temperature Hard sizing and inside temperature I did a auto size simulation in the purpose to find the cooling capacity of every roo |
2018-11-26 20:13:54 -0500 | edited question | AC hard sized, number of people and variation of the inside temperature Effect of the number of people on the inside temperature (hard size cooling capacity) I did a auto size simulation in th |
2018-11-26 06:57:51 -0500 | edited question | AC hard sized, number of people and variation of the inside temperature Effect of the number of people on the inside temperature (hard size cooling capacity) I did a auto size simulation in th |
2018-11-26 02:59:00 -0500 | edited question | AC hard sized, number of people and variation of the inside temperature Relation between inside temperature, hard size cooling capacity and number of people I did a auto size simulation in the |
2018-11-26 01:59:54 -0500 | asked a question | AC hard sized, number of people and variation of the inside temperature Relation between inside temperature, hard size cooling capacity and number of people I did a auto size simulation in the |
2018-11-25 19:45:47 -0500 | commented answer | Coil sizing check in E+ With E+, How Can we get this report " Enthalpy outdoor (36oC, 0.02207g/kg) = 92.87 kJ/kg ;Enthalpy return air/room air ( |
2018-11-22 01:21:34 -0500 | commented answer | What ventilation system, E+ does and doesnt take into account for sizing calculation ? Thank you for the tips. "This is an open new feature request", it could be very useful and why not add an option to sum |
2018-11-15 07:57:56 -0500 | edited question | What ventilation system, E+ does and doesnt take into account for sizing calculation ? What ventilation system, E+ does and doesnt take into account for sizing calculation ? I am working on a project with DO |
2018-11-15 07:57:53 -0500 | edited question | What ventilation system, E+ does and doesnt take into account for sizing calculation ? What ventilation system, E+ does and doesnt take into account for sizing calculation ? I am working on a project with DO |
2018-11-15 07:03:46 -0500 | edited question | What ventilation system, E+ does and doesnt take into account for sizing calculation ? What ventilation system, E+ does and doesnt take into account for sizing calculation ? I am working on a project with DO |