2019-06-12 04:34:04 -0500 marked best answer Something wrong with my HVAC --> Unreasonable heating consumption results

Hey everyone, I recently faced a problem that I tried to fix with some users, but I didn't provide them with enough informations which was confusing. So I am posting this question to explain my issue from the beginning.

I am modelling a residential building of 12 flats whose HVAC should be as follows: District heating for both water usage and floor heating + Heat recovery ventilaion

So these 3 screenshots show the hot water system configuration: image description

As you can see below it is a mixed water heater but the fuel type is District Heating as suggested by @egillmor (otherwise the ''DHW usage will show up as heating end use rather than water system end use.'') image description

image description

The rest of the screenshots will show the HR ventilation and radiant floor loop

image description

Following the instructions of @MatthewSteen in this post I did this : image description

The simulation ran successfully, but the District heating consumption chart was illogical, as shown below: the consumption is more or less the same from April to November and it is also low in January, while it should be low fi the summer and gradually increasing during the winter. image description

Same problem the the Demand image description

Does anyone have any idea about what is wrong with my HVAC that had led to that result ??

I hope I made it clear , but if there is any information missing, please let me know.

I would appreciate a lot your help ! :)

2019-06-12 04:34:04 -0500 received badge  Self-Learner (source)
2018-09-20 09:10:31 -0500 commented answer Shading created by PV array on top of roof

Aaah okay, I actually already have this measure and the only result related to PV generation is this even though I used

2018-09-20 09:10:02 -0500 commented answer What is the best way to model a solar panel in open studio?

@rpg777 thanks for your reply but I actually used the add output variable measure to see: the Generator Requested Electr

2018-09-20 09:06:06 -0500 commented answer Shading created by PV array on top of roof

Aaah okay, I actually already have this measure and the only result related to PV generation is this even though I used

2018-09-20 09:03:56 -0500 commented answer Shading created by PV array on top of roof

Aaah okay, I actually already have this measure and the only result related to PV generation is this even though I used

2018-09-20 08:33:46 -0500 commented answer Shading created by PV array on top of roof

Perfect ! Thanks

2018-09-20 07:30:53 -0500 commented answer Shading created by PV array on top of roof

@David Goldwasser, By 'the standard reporting measure', you meant the Add Output Variable OS measure ? Or another measur

2018-09-20 03:59:30 -0500 commented answer Is OpenStudio or EnergyPlus able to simulate solar thermal panels integrated to existing HVAC systems?

@macumber, I tried to simulate a system using SolarCollector:IntegralCollectorStorage, by draging it to the supply side

2018-09-20 03:49:35 -0500 commented answer Active indirect solar hot water collector modeling

@Alex Vlachokostas, I understand that you have added a Water Heater and used it as an tank (and also to link the first l

2018-09-19 15:09:23 -0500 commented answer Which side of the plant loop for Solar Collector in E+/OpenStudio?

@michael , did it work ?

2018-09-19 14:47:56 -0500 commented answer solar collector panel to DHW

@aparker I am using openStudio and I did like that but I got severe error saying PlantEquipmentList="PLANT LOOP 1 HEATIN

2018-09-19 14:47:40 -0500 commented answer solar collector panel to DHW

I am using openStudio and I did like that but I got severe error saying PlantEquipmentList="PLANT LOOP 1 HEATING EQUIPME

2018-09-19 13:46:26 -0500 commented answer What is the best way to model a solar panel in open studio?

@David Goldwasser where can I find the results concerning the PV? Because after adding the measure and running I found t

2018-09-19 05:24:47 -0500 commented question EnergyPlus results after using CHP

Thanks for the answer, but could you be more specific please? How can I simulate the DesignDays only? Should I type YES

2018-09-19 05:11:39 -0500 commented question EnergyPlus results after using CHP

Thanks for the answer, but could you be more specific please? How can I simulate the DesignDays only? Should type YES fo

2018-09-19 04:24:39 -0500 commented question EnergyPlus results after using CHP

Thanks for the answer, but could you be more specific please? How can I simulate the DesignDays only? and which variable

2018-09-17 04:53:30 -0500 edited question EnergyPlus results after using CHP

EnergyPlus results after using CHP Hi everyone, I used 2 Generator:MicroCHP to power a residential building, one for t

2018-09-16 17:07:59 -0500 marked best answer How to implement one component (CHP unit) for two plant loops ?

Hi !

I am supposed to simulate a building with only one CHP unit (15kw), but it seems like I need to implement 2 different CHP because I have 2 plantloops as shown below:

image description image description

when I tried to use just one CHP in e+, the simulation failed saying that there is one component that has different nodes. So instead of using one CHP with a power of 15kW, I am using two units of 7.5kW each, but the results won't be accurate, as it should be.

Does anyone you have any suggestion that could help me with this ?


NB: I used openstudio at the beginning but it turned out that I can not realize this kind of design (MicroCHP or MicroTurbine unit) with OS, even if it is in the loop in the images above, but it is not taken into account during the simulation and does not appear in the results, so I had to export the file into IDF file and I then I added the MicroTurbine.

2018-09-16 12:51:55 -0500 commented answer How to implement one component (CHP unit) for two plant loops ?

Good idea !! I did like that and it ran finally but the result doesn't make any sense here is the table of the End Uses

2018-09-16 12:49:41 -0500 commented answer How to implement one component (CHP unit) for two plant loops ?

Good idea !! I did like that and it ran finally but the result doesn't make any sense here is the table of End Uses. D

2018-09-16 07:13:46 -0500 commented answer How to implement one component (CHP unit) for two plant loops ?

who are already defined as water inlet / outlet node in the Boiler object.

2018-09-16 07:13:04 -0500 commented answer How to implement one component (CHP unit) for two plant loops ?

Now I tried to use the same use side node name for the water heater as the node name assigned in the demand branch of th

2018-09-15 19:24:26 -0500 commented answer How to implement one component (CHP unit) for two plant loops ?

@mldichter, I tried to do as you said but from the beginning in OS, it doesn't let me drag the boiler nor the Water heat

2018-09-15 19:24:15 -0500 commented answer How to implement one component (CHP unit) for two plant loops ?

@mldichter, I tried to do as you said but from the beginning in OS, it doesn't let me drag the boiler nor the Water heat

2018-09-15 19:23:58 -0500 commented answer How to implement one component (CHP unit) for two plant loops ?

@mldichter, I tried to do as you said but from the beginning in OS, it doesn't let me drag the boiler nor the Water heat

2018-09-15 19:04:19 -0500 asked a question EnergyPlus results after using CHP

EnergyPlus results after using CHP Hi everyone, I used 2 Generator:MicroCHP to power a residential building, one for t

2018-09-14 16:59:59 -0500 commented answer How to implement Gas Combined Heat and Power CHP system in HVAC using OpenStudio

I just asked a question about that here

2018-09-14 16:58:44 -0500 asked a question How to implement one component (CHP unit) for two plant loops ?

How to implement one component (CHP unit) for two plant loops ? Hi ! I am supposed to simulate a building with only on

2018-09-14 16:56:14 -0500 commented answer How to implement Gas Combined Heat and Power CHP system in HVAC using OpenStudio

@mldichter, I still have a problem though, concerning the number of CHP. I am supposed to simulate the building with on

2018-09-14 16:42:33 -0500 commented answer How to implement Gas Combined Heat and Power CHP system in HVAC using OpenStudio

@mldichter, I still have a problem though, concerning the number of CHP. I am supposed to simulate the building with on

2018-09-14 16:33:31 -0500 commented answer How to implement Gas Combined Heat and Power CHP system in HVAC using OpenStudio

@mldichter, Thank you, but I finally knew how to implement it correctly after several trials (it's my 1st time using e+

2018-09-14 16:32:59 -0500 commented answer How to implement Gas Combined Heat and Power CHP system in HVAC using OpenStudio

@mldichter, Thank you, but I finally knew how to implement it correctly after several trials (it's my 1st time using e+

2018-09-14 16:32:32 -0500 commented answer How to implement Gas Combined Heat and Power CHP system in HVAC using OpenStudio

@mldichter, thx, I finally knew how to implement it correctly after several trials (it's my 1st time using e+ so I didn'

2018-09-14 16:31:06 -0500 commented answer How to implement Gas Combined Heat and Power CHP system in HVAC using OpenStudio

@mldichter, I finally knew how to implement it correctly after several trials (it's the 1st time using e+ so I didn't kn

2018-09-14 16:30:52 -0500 commented answer How to implement Gas Combined Heat and Power CHP system in HVAC using OpenStudio

@mldichter, I actually knew how to implement it correctly after several trials (it's the 1st time using e+ so I didn't k

2018-09-14 16:30:09 -0500 commented answer How to implement Gas Combined Heat and Power CHP system in HVAC using OpenStudio

@mldichter, I actually knew how to implement it correctly after several trials (it's the 1st time using e+ so I didn't k

2018-09-14 10:21:39 -0500 commented answer Cogeneration unit not turning on in E

@Julien Marrec, could you please share with us IDF File after correction? Because I ran the IDF file you shared above af

2018-09-14 10:21:31 -0500 commented answer Cogeneration unit not turning on in E

@Julien Marrec, could share with us IDF File after correction? Because I ran the IDF file you shared above after adding

2018-09-14 03:39:11 -0500 commented question Openstudio crashing: invalid weather file - all measures gone - simulation fails

@David Goldwasser, No I am not working from a drive, and it has not happened since. But I will certainly let you know if