2022-05-05 11:45:08 -0500 commented question Total cooling energy needed- Demand or consumption?

Hi Jim. Thanks for your time. Firstly, I wanted to be sure if cooling coil electric energy (joules) gives total annual

2022-05-03 14:12:49 -0500 asked a question Total cooling coil electric energy or end use cooling energy- demand or consumption?

Total cooling coil electric energy or end use cooling energy- demand or consumption? What do the values for heating/cool

2022-05-03 14:11:25 -0500 asked a question Total cooling energy needed- Demand or consumption?

Total cooling energy needed- Demand or consumption? What do the values for heating/cooling in EP results correspond to-

2022-03-23 23:57:55 -0500 commented question Why is air temp. (without conditioning) higher for middle floors?

Thanks for your response David. I would like to inform you that the building being simulated is situated in a warm humi

2022-03-23 10:21:37 -0500 asked a question Why is air temp. (without conditioning) higher for middle floors?

Why is air temp. (without conditioning) higher for middle floors? Hi all I am running an energy simulation for a three-

2022-03-14 13:42:06 -0500 received badge  Student (source)
2022-03-14 13:39:09 -0500 asked a question HVAC NOT DISPLAYING OUTPUTS IN SIMULATION RESULTS

HVAC NOT DISPLAYING OUTPUTS IN SIMULATION RESULTS Hi All I have just started performing energy simulations with honey b

2022-03-13 17:08:30 -0500 commented answer ZoneHVAC:IdealLoadsAirSystem results in zero under source electricty cooling

@rraustad, Thank you for the response!

2022-03-13 12:42:11 -0500 marked best answer ZoneHVAC:IdealLoadsAirSystem results in zero under source electricty cooling

I have just started working with honeybee. I had not selected any HVAC system for my model. However, the energy simulation CSV result file shows value under End Uses- district cooling (KWh) as a non- null value. Further, even if I consider that the default HVAC system is set to ideal air load system (is it so?), why is the value for electricity corresponding to district cooling under end uses zero?

Please suggest!

2022-03-13 12:42:11 -0500 received badge  Scholar (source)
2022-03-10 14:24:09 -0500 asked a question ZoneHVAC:IdealLoadsAirSystem results in zero under source electricty cooling

ZoneHVAC:IdealLoadsAirSystem results in zero under source electricty cooling I have just started working with honeybee.