2018-04-17 05:36:16 -0500 commented question energy plus input file

I think you need to provide a little more information if you want a worthwhile answer. In what way is the file not worki

2018-04-17 05:35:01 -0500 received badge  Critic (source)
2018-04-06 08:32:08 -0500 marked best answer Monodraught windcatcher IES

I'm having difficulty simulating a naturally ventilated space using the Monodraught windcatcher components. The model will run if I don't add any heat gains to the space, however if I add any heat gains the analysis fails due to:

"Instability in room. Possible remedies: reduce time step; set radiant fraction to 0; check gain and ventilation levels; reduce MacroFlo opening areas."

Does anyone have any ideas?

2018-04-06 08:32:08 -0500 received badge  Scholar (source)
2018-04-06 08:31:59 -0500 answered a question Monodraught windcatcher IES

Monodraught helped me get to the bottom of this. Should anyone have a similar problem in the future see below: The ther

2018-04-05 09:57:32 -0500 asked a question Monodraught windcatcher IES

Monodraught windcatcher IES I'm having difficulty simulating a naturally ventilated space using the Monodraught windcatc

2018-03-29 10:17:53 -0500 asked a question Monodraft windcatchers in IES

Monodraft windcatchers in IES I'm trying to model a naturally ventilated space in IES which will have roof mounted turre

2018-03-05 08:57:05 -0500 edited answer Exergy based MPC formulation question

The term you are looking at is the room temperature (as denoted by the 'r'). The subscript 'k' is the time step. Edit:

2018-03-05 08:44:13 -0500 answered a question Exergy based MPC formulation question

The term you are looking at is the room temperature. The subscript 'k' is the time step.

2018-02-21 08:29:59 -0500 received badge  Teacher (source)
2018-02-21 04:54:33 -0500 answered a question How can I run a simulation for 100 days

You can change the length of simulation by editing the RunPeriod object. Pretty much the first thing you will see when y

2018-02-19 14:04:00 -0500 commented answer Add rooftop PV azimuth

Thanks for your response, I really need to include the surface orientation as I'm using the measure as part of an automa

2018-02-14 04:16:37 -0500 received badge  Autobiographer
2018-02-14 03:33:02 -0500 commented answer Add rooftop PV azimuth

Thanks David for your fast and helpful response. I will give that a try.

2018-02-14 03:28:00 -0500 received badge  Supporter (source)
2018-02-13 12:52:14 -0500 received badge  Student (source)
2018-02-13 12:50:55 -0500 asked a question Add rooftop PV azimuth

Add rooftop PV azimuth I'd like to adapt the add rooftop pv measure to only apply to roof surfaces which face south, or