2018-03-28 07:54:55 -0500 | answered a question | Energyplus example error I've solved "Socket communication received error value " 1" " problem by playing with Timestep in .idf file. I decreased |
2018-03-28 07:24:05 -0500 | commented answer | ExternalInterface: Socket communication received error value " 1" at time = 1416.16 hours Yes I got this error from .err file. I am running matlab script that supposed to control my Temperature setpoints. But i |
2018-03-16 11:23:12 -0500 | marked best answer | Exergy based MPC formulation question The paper is attached. Paper: link - http://ieeexplore.ieee.org/document/7... I was trying to understand Exergy MPC formulation but I failed to understand sme trems in it (9th equation): regadring term T with 'r' and 'k' subscripts. Is anyone can explain little bit it would be great. P.S. I was trying to formulate this MPC for Energy plus formulation C:\fakepath\Screenshot.jpg |
2018-03-16 11:23:12 -0500 | received badge | ● Scholar (source) |
2018-03-16 11:22:55 -0500 | commented answer | Exergy based MPC formulation question Thanks for response, the paper didn't specify in details all terms, unfortunately |
2018-03-15 09:05:57 -0500 | edited question | Measure entrance temperature of supply air into the room and exit temperature in the control volume Energy+ | How to measure entrance temperature of supply air into the room and exit temperature in the control volume I |
2018-03-15 04:49:57 -0500 | edited question | Measure entrance temperature of supply air into the room and exit temperature in the control volume Energy | How to measure entrance temperature of supply air into the room and exit temperature in the control volume I a |
2018-03-14 15:48:08 -0500 | asked a question | Measure entrance temperature of supply air into the room and exit temperature in the control volume Energy | How to measure entrance temperature of supply air into the room and exit temperature in the control volume I a |
2018-03-12 12:12:16 -0500 | received badge | ● Teacher (source) |
2018-03-12 11:10:59 -0500 | edited question | MLE+ | RadiantMPC Example question MLE+ | RadiantMPC Example question I was trying to figure out how RadiantMPC works. 'SetUpMPC.m' file loads 'ssModel.ma |
2018-03-12 11:10:42 -0500 | edited question | MLE+ | RadiantMPC Example question MLE+ | RadiantMPC Example question I was trying to figure out how RadiantMPC works. 'SetUpMPC.m' file loads 'ssModel.ma |
2018-03-12 10:54:56 -0500 | answered a question | MLE+ | RadiantMPC Example question I partly figured out that we use "Package Data" from 2.SystemID MLE+ front-end to wrap data simulated in Energy + into M |
2018-03-10 06:08:56 -0500 | edited question | MLE+ | RadiantMPC Example question MLE+ | RadiantMPC Example question I was trying to figure out how RadiantMPC works. 'SetUpMPC.m' file loads 'ssModel.ma |
2018-03-10 06:00:58 -0500 | received badge | ● Editor (source) |
2018-03-10 06:00:58 -0500 | edited question | MLE+ | RadiantMPC Example question MLE+ | RadiantMPC Example question I was trying to figure out how RadiantMPC works. 'SetUpMPC.m' file loads 'ssModel.ma |
2018-03-10 06:00:00 -0500 | asked a question | MLE+ | RadiantMPC Example question RadiantMPC Example question I was trying to figure out how RadiantMPC works. 'SetUpMPC.m' file loads 'ssModel.mat' file |
2018-03-05 12:41:26 -0500 | commented answer | Exergy based MPC formulation question Thanks for response, the paper didn't spacify in details all terms, unfortunately |
2018-03-04 03:14:12 -0500 | edited question | Exergy based MPC formulation question Exergy based MPC formulation question The paper is attached. Paper: link - http://ieeexplore.ieee.org/document/7170974/ |
2018-03-04 03:09:43 -0500 | asked a question | Exergy based MPC formulation question Exergy based MPC formulation question The paper is attached. I was trying to understand Exergy MPC formulation but I fa |
2018-02-22 11:57:07 -0500 | commented answer | How can I simulate a CoolingCoilDX with a high air flow (rated air volume flow rate)? Did not get an answer, can someone clarify how parent object should changed if DXcoil is set to autosized. Can be CoilSy |
2018-02-21 23:41:16 -0500 | asked a question | ExternalInterface: Socket communication received error value " 1" at time = 1416.16 hours ExternalInterface: Socket communication received error value " 1" at time = 1416.16 hours I'm using MLE+ to run my exter |
2018-02-21 23:34:15 -0500 | commented answer | Error: readBND, Did not recognize: Controlled Zone Return Thanks for reply, the problem dissapears for lower versions of Energy plus |
2018-02-21 14:36:20 -0500 | received badge | ● Student (source) |
2018-02-21 09:45:03 -0500 | asked a question | Error: readBND, Did not recognize: Controlled Zone Return Error: readBND, Did not recognize: Controlled Zone Return "Error: Error: readBND, Did not recognize: Controlled Zone Ret |
2018-02-15 09:31:26 -0500 | received badge | ● Supporter (source) |
2018-02-15 09:00:22 -0500 | answered a question | Optimize HVAC consumptions by changing HVAC setpoints Correct me if i'm wrong. Assuming you working with Energy plus directly you can use BCVTB external interface to overwrit |