First time here? Check out the Help page!
2021-11-05 14:56:30 -0500 | received badge | ● Popular Question (source) |
2018-11-04 01:51:28 -0500 | commented answer | Adding multiple electric heaters Thank you. But the situation I have is that I have 5 identical and independent electrical heaters in a villa. I assume t |
2018-10-18 08:45:56 -0500 | asked a question | Adding multiple electric heaters Adding multiple electric heaters Hi, I defined an electric heater that is used in individual bathrooms using “Service H |
2018-09-20 01:57:28 -0500 | commented answer | Importance of DDY and STAT weather files Thank you very much |
2018-09-20 01:57:26 -0500 | commented answer | Importance of DDY and STAT weather files Thank you very much |
2018-09-20 01:57:26 -0500 | received badge | ● Commentator |
2018-09-16 08:15:37 -0500 | asked a question | Importance of DDY and STAT weather files Importance of DDY and STAT weather files Hi, I generated my own EPW files with the help of "Elements" software. OpenStu |
2018-09-06 01:46:06 -0500 | commented answer | Calibration using GENOUD optimization algorithm in PAT Thank you very much. |
2018-09-06 01:45:54 -0500 | commented answer | Calibration using GENOUD optimization algorithm in PAT Very useful. Thanks a lot. |
2018-09-06 01:45:34 -0500 | marked best answer | Calibration using GENOUD optimization algorithm in PAT Hi, I trying to calibrate a model using the utility data. I read in a paper on the subject which is titled “ A GRAPHICAL TOOL FOR CLOUD-BASED BUILDING ENERGY SIMULATION” that “to minimize the difference between actual and model energy use. Therefore, we selected the GENOUD optimization algorithm and an objective function that corresponds to CV(RMSE).” It seems that the GENOUD method is replaced now in PAT with the RGENOUD. I assume these are very much the same. The question is: how to put an objective function that corresponds to CV(RMSE) in PAT. And how does the optimization method work based on this function? |
2018-09-06 01:45:34 -0500 | received badge | ● Scholar (source) |
2018-09-04 05:38:49 -0500 | asked a question | Calibration using GENOUD optimization algorithm in PAT Calibration using GENOUD optimization algorithm in PAT Hi, I trying to calibrate a model using the utility data. I read |
2018-08-29 11:01:54 -0500 | commented answer | calibration report with utility bill in 2.6.0 Great. Thanks. However, the one that actually worked with me is the "Calibration Report Enhanced". |
2018-08-29 07:42:56 -0500 | edited question | calibration report with utility bill in 2.6.0 calibration report with utility bill in 2.6.0 Hi, I am trying to have the calibration report that graphically shows the |
2018-08-29 07:42:10 -0500 | received badge | ● Editor (source) |
2018-08-29 07:42:10 -0500 | edited question | calibration report with utility bill in 2.6.0 calibration report with utility bill in 2.6.0 Hi, I am trying to have the calibration report that graphically shows the |
2018-08-29 07:41:02 -0500 | asked a question | calibration report with utility bill in 2.6.0 calibration report with utility bill in 2.6.0 Hi, I am trying to have the calibration report that graphically shows the |
2018-07-25 09:41:32 -0500 | commented answer | Which Sampling (algorithmic) Method to use with PAT 2 Thank you. This was very useful |
2018-07-21 07:13:43 -0500 | asked a question | instances are not launching from PAT2 instances are not launching from PAT2 I was able to run simulations from PAT2 on AWS many times. Suddenly, instances sen |
2018-07-19 17:10:01 -0500 | asked a question | Which Sampling (algorithmic) Method to use with PAT 2 Which Sampling (algorithmic) Method to use with PAT 2 I want to calculate the cooling load for a building when changing |
2018-06-09 07:19:40 -0500 | commented question | PAT job is queued but is not running version: 2.5.0 |
2018-06-06 13:44:01 -0500 | commented question | PAT job is queued but is not running version: 2.5.0 |
2018-06-06 06:49:41 -0500 | edited question | PAT job is queued but is not running PAT job is queued but is not running Attached is a screen shot of the errors. I filtered them. I hope this can reveal th |
2018-06-05 17:31:15 -0500 | commented question | PAT job is queued but is not running This is a sample of the errors vendor-ad64e72158.js:24014 422/404 Error...GETting datapoint json instead vendor-ad64 |
2018-06-05 17:26:37 -0500 | commented question | PAT job is queued but is not running Yes, I have several errors. There seems to be no way to add an attachment or captured screen to this comment area |
2018-06-05 15:24:56 -0500 | commented question | PAT job is queued but is not running Thank You. I restarted and ran again but still the same issue. What details can I provide from the log? It seems that |
2018-06-04 15:54:10 -0500 | asked a question | PAT job is queued but is not running PAT job is queued but is not running I am trying to run a sample run with two alternatives. The jobs are queued for more |
2018-04-29 02:57:03 -0500 | commented answer | Are there good videos to explain the use of the new versions of the paramatric analysis tool? Thanks a lot. This was very useful. |
2018-04-26 10:40:38 -0500 | received badge | ● Student (source) |
2018-04-26 10:34:06 -0500 | asked a question | Are there good videos to explain the use of the new versions of the paramatric analysis tool? Are there good videos to explain the use of the new versions of the paramatric analysis tool? I am trying to learn using |
2018-01-27 05:41:36 -0500 | received badge | ● Supporter (source) |