2020-05-29 19:21:26 -0500 answered a question Zero daylight Autonomy

I'm not expert working with Radiance through Openstudio, but: check daylighting control point(s) setup. Info: Removing

2020-05-29 19:13:41 -0500 commented question New actuator request

I cannot understand your question. Please explain it better if yoyu need help

2020-05-29 19:07:55 -0500 edited answer I don't want EnergyPlus to rearrange my IDF text file

Are you doing some little modifications to your IDF through IDF Editor before running it through EP Lunch? if so, check

2020-05-29 19:07:00 -0500 answered a question I don't want EnergyPlus to rearrange my IDF text file

Are you doing some little modifications to IDF through IDF Editor before running? if so, check "File" > "Save Options

2020-05-29 18:51:31 -0500 edited answer Find surface from the error

Try to go to "Model Options" > "Advanced" > "Lump similar wondows on a surface" and deselect it. It should run n

2020-05-29 18:51:09 -0500 answered a question Find surface from the error

Try to go to "Model Options" > "Advanced" > "Lump similar wondows on a surface" and deselect it. It should run

2020-05-26 18:55:58 -0500 edited answer Make My own Output Variable in Energyplus?

As alternative of what Aly suggested, , always through EMS: 1- create 3 EMS:Sensors to take in your 3 variable (same as

2020-05-26 18:55:31 -0500 edited answer Make My own Output Variable in Energyplus?

As alternative of what Aly suggested, , always through EMS: 1- create 3 EMS:Sensors to take in your 3 variable (same as

2020-05-26 18:55:07 -0500 answered a question Make My own Output Variable in Energyplus?

As alternative of what Aly suggested, , always through EMS: 1- create 3 EMS:Sensors to take in your 3 variable (same as

2020-05-25 11:53:54 -0500 edited answer EMS Error When Using PV Generation as Sensor

Instead "Average" you have to put your Electric Load Center object name. It requires the "Key Name", that is the name o

2020-05-25 11:52:31 -0500 answered a question EMS Error When Using PV Generation as Sensor

Instead "Average" you have to put your Electric Load Center object name

2020-05-25 07:09:37 -0500 answered a question hourly output loading too large in Design Builder

Have you asked for temps node/mass flow rate node output, or surface heat transfer? It can results in a tons of output D

2020-05-22 16:01:32 -0500 commented answer Set-point tolerance in energyplus

It could be a convergence temperature/load issue, depending on the equipment involved.

2020-05-22 15:55:40 -0500 commented answer Why Return fan CFM ≠ Supply fan CFM - Exhaust fan CFM?

Yes, it is very common that HVAC systems has supply air flow> return air, especially to avoid unwanted infiltration.

2020-05-21 17:46:12 -0500 answered a question Does anyone know how to model infrared heaters?

EnergyPlus has a proper obj to model it: ZoneHVAC:HighTemperatureRadiant

2020-05-21 17:07:23 -0500 edited answer Fanger Model PPD output problems

Work efficiency 0.7 is not reasonable. Usually it shlud be 0 or around it. It rapresent the mechanical work done by pe

2020-05-21 16:59:55 -0500 answered a question Fanger Model PPD output problems

Work efficiency 0.7 is not reasonable. Usually it shlud be 0 or around it. It rapresent the mechanical work done by pe

2020-05-21 16:44:00 -0500 answered a question scheduled fan speed control at a HVAC-PTAC system

Not directly. Hopefully you can do it via EMS accessing a proper sensor. Instead, for the Outdoor Air Fraction, you c

2020-05-21 16:30:33 -0500 commented answer Put the pump On and the chiller is OFF in the same loop

In my vision is the same. What should happen, thermodynamically speaking, with the flow passing through the Chiller turn

2020-05-21 16:30:33 -0500 received badge  Commentator
2020-05-21 13:12:40 -0500 answered a question How to implement subroutine to calculate mean of daily recorded attributes every 3 month?

You have to code it in Erl through EMS EnergyPlus class objects. You should use a TrendAevrage variable on your min val

2020-05-21 13:02:38 -0500 commented answer Fan electricity postprocessing Ideal Loads Air System results

Yes it makes sense. EnergyPlus direct fan modelling allows you to model the actual fan power starting from a rated value

2020-05-21 13:02:29 -0500 commented answer Fan electricity postprocessing Ideal Loads Air System results

Yes it makes sense. EnergyPlus direct fan modelling allows you to model the actual fan power starting from a rated value

2020-05-21 13:01:45 -0500 commented answer Fan electricity postprocessing Ideal Loads Air System results

Yes it makes sense. EnergyPlus direct fan modelling allows you to model the actual fan power starting from a rated value

2020-05-21 12:38:57 -0500 answered a question Put the pump On and the chiller is OFF in the same loop

What is you purpose? With a Pump:ConstantSpeed you have the pump running even if there is no load on the loop and there

2020-05-21 12:25:35 -0500 answered a question I am unable to produce output file from energyplus EP-Launch program kindly tell solution.

It could be a Euclid vs EnergyPlus version lack of compatibility. As @Aaron Boranian suggested, there is a geometry iss

2020-05-21 12:07:21 -0500 answered a question How to control Energyplus zone temperature?

What about the fan? It may happen that the air flow rate compensates (increasing) the reduced water flow rate

2020-05-21 11:58:58 -0500 answered a question Why Return fan CFM ≠ Supply fan CFM - Exhaust fan CFM?

EnergyPlus requires a single loop (obj AirLoopHVAC / PlantLoop / CondenserLoop) to be balanced: if you supply 6000 CFM y

2020-05-20 14:53:07 -0500 answered a question Rated Supply Fan Power Per Volume Flow Rate

These are: for DX Cooling Coil: Rated Evaporator Fan Power Per Volume Flow Rate for DX Heating Coil: Rated Evaporator

2020-05-20 12:35:35 -0500 commented answer Fan electricity postprocessing Ideal Loads Air System results

Usually MHRV cannot meet the total Clg/Htg loads of a dwelling ; it works only on the fresh air load contribution. But o

2020-05-20 12:35:14 -0500 commented answer Fan electricity postprocessing Ideal Loads Air System results

Usually MHRV cannot meet the total Clg/Htg loads of a dwelling ; it works only on the fresh air load contribution. But o

2020-05-20 12:35:04 -0500 commented answer Fan electricity postprocessing Ideal Loads Air System results

Usually MHRV cannot meet the total Clg/Htg loads of a dwelling ; it works only on the fresh air load contribution. But o

2020-05-20 11:25:27 -0500 edited answer Central Heat Pump System Plant temperatures are getting far too cold

Hi, I've had the same problem but shifted to the overheating (and not fortunately during the warm up, so i've been able

2020-05-20 11:24:16 -0500 edited answer How to see solar radiation plot?

Hi ,You have to ask for those variables you want to graph. They could be : Site Diffuse Solar Radiation Rate per Area

2020-05-20 11:23:08 -0500 edited answer energyplus weather file

Hi, I've always worked (very fine) through the WeatherConverter E+ auxiliary software with a simple TXT file (filled wit

2020-05-19 18:47:19 -0500 answered a question How to see solar radiation plot?

Hi ,You have to ask for those variables you want graph. They could be : Site Diffuse Solar Radiation Rate per Area Sit

2020-05-19 18:39:20 -0500 answered a question energyplus weather file

Hi, I've always worked (very fine) with a simple TXT file (filled with data from a spraedsheet) and DEF file (filled wit

2020-05-19 18:26:43 -0500 answered a question Central Heat Pump System Plant temperatures are getting far too cold

Hi, I've had the same problem but shifted to the overheating (and not fortunately during the warm up, so i've been able

2020-05-19 18:14:22 -0500 commented answer Contradiction between cooling load and u- value of glass

Understandings like this are the elements that gives value to dynamic energy simulaiton.

2020-05-19 18:01:55 -0500 answered a question Fan electricity postprocessing Ideal Loads Air System results

Hi, in general your assumptions are right. May you want remember that in Detailed energyplus simulations Fan consumption

2020-05-19 16:53:49 -0500 answered a question How to connect two or more AHU

Hi, you have to converte your 3 AHUs in just one, becaouse in energyplus you can have only one air terminal unit for eac

2020-05-19 16:39:09 -0500 answered a question Set-point tolerance in energyplus

Hi, As far as I know there is no way to reduce it, because there is no tolerance: this is energyplus starting point. Ins

2020-04-10 10:50:28 -0500 edited answer zone air temperature in cooling mode is the same that heating

Some points on wich you may want to think about: Are you sure to have significant internal load (expecially if your bu

2020-04-10 10:50:19 -0500 edited answer zone air temperature in cooling mode is the same that heating

Some points on wich you may want to think about: - Are you sure to have significant internal load (expecially if your bu

2020-04-10 10:49:41 -0500 answered a question zone air temperature in cooling mode is the same that heating

Some poiint on wich you can think about: - Are you sure to have significant internal load (expecially if your building i

2020-03-26 11:00:38 -0500 commented answer District heating in EnergyPlus

Yes, for sure you're right. I was supposing for a district heating serving multiple buildings, that is a District Heatin

2020-03-26 05:51:43 -0500 edited answer District heating in EnergyPlus

Hi, you have to connect your hot water loop to the District Heating object as hot water generator (Primary Supply Side

2020-03-26 04:17:05 -0500 edited question Inconsistent Chilled Water Node Temperatures

Inconsistent Chilled Water Node Temperatures Hi All, I'm working on a complex chilled water plant on EnergyPlus via Des

2020-03-26 04:16:04 -0500 edited answer Inconsistent Chilled Water Node Temperatures

So, do I have to think it is a sort of "bug" of the plant solver (taht is: the software does not work properly itself)?

2020-03-26 04:15:48 -0500 answered a question Inconsistent Chilled Water Node Temperatures

So, do I have to think it is a sort of "bug" of the plant solver (taht is: the software does not work properly itself)?