2018-01-09 04:04:21 -0500 commented answer Ground temperature in openstudio

yes i saw, but even if i impost none for all, it returns me error on surface

2018-01-05 06:00:32 -0500 commented answer Ground temperature in openstudio

I can not make it go. gives me errors: [12: 54: 53.930441 ERROR] Could not set argument 'footWallConstName' to value 'c

2018-01-05 04:33:42 -0500 commented answer Ground temperature in openstudio

not yet. I have to click on apply measure. create a new one from the template. and make a paste copy of the link code in

2018-01-05 02:26:31 -0500 commented answer Ground temperature in openstudio

the problem is created when I calculate the model without hvac systems. I have a supermarket as a model. 3 walls on 4 ag

2018-01-05 02:14:14 -0500 received badge  Commentator
2018-01-05 02:14:14 -0500 commented answer Ground temperature in openstudio

the problem is created when I calculate the model without hvac systems. I have a supermarket as a model. 3 walls on 4 ag

2018-01-04 03:10:54 -0500 asked a question Ground temperature in openstudio

Ground temperature in openstudio I wanted to change the ground temperature in openstudio. I saw in other posts that defa

2017-12-06 11:18:52 -0500 edited question compressor setpoint temperature abnormal electrical consumption

compressor setpoint temperature abnormal electrical consumption I set a waterheater heat pump combined with a low temper

2017-12-06 11:17:12 -0500 edited question compressor setpoint temperature abnormal electrical consumption

compressor setpoint temperature abnormal electrical consumption I set a waterheater heat pump combined with a low temper

2017-12-06 11:17:12 -0500 received badge  Editor (source)
2017-12-06 11:15:35 -0500 edited question compressor setpoint temperature abnormal electrical consumption

compressor setpoint temperature abnormal electrical consumption I set a waterheater heat pump combined with a low temper

2017-12-06 11:11:37 -0500 asked a question compressor setpoint temperature abnormal electrical consumption

compressor setpoint temperature abnormal electrical consumption I set a waterheater heat pump combined with a low temper

2017-11-30 11:29:22 -0500 asked a question Curve Fit tool problem in data output

Curve Fit tool problem in data output I used the spreadsheet, located in the energy plus installation folder, to calcula

2017-11-30 11:17:22 -0500 marked best answer radiant floor simulation ok but wrong output

image description

image description image description image description image description image description image description image description image description I set the plant loop as the first two figure, the internal source as shown below, the setpoint manager like the following three figures. after running the simulation I have no fatal error and you can see a power consumption for heating, but looking at the indoor temperatures seems like nothing warms up. I'm sorry if i inserted too many images. someone has a suggestion to give me?

2017-11-29 11:17:45 -0500 commented question radiant floor simulation ok but wrong output

yes. thanks. now it's ok.

2017-11-29 04:34:29 -0500 commented question radiant floor simulation ok but wrong output

thnak you very much. i found it. i've never scroll in this tab.

2017-11-28 10:12:39 -0500 commented question radiant floor simulation ok but wrong output

but in openstudio where do I have to set these fields?

2017-11-22 03:36:08 -0500 commented question radiant floor simulation ok but wrong output

for information: the energy consumption is now half (58,2 kBtu)

2017-11-22 03:26:53 -0500 commented question radiant floor simulation ok but wrong output

I tried to delete the first three layers of the internal source and now it works. the internal temperatures follow the s

2017-11-21 10:22:11 -0500 marked best answer failed openstudio simulation with low temp radiant variable flow

Hi, I'm just starting to learn openstudio so be patient. I modeled a residential building with radiator system and the simulation was successful. then I wanted to simulate a radiant floor, and I used the measure "AedgOfficeHvacRadiantDoas". I've seen that the measure has changed some things: - created internal source (on the tab Constructions) that i've added in interior surface. - (on the tab thermal zone) replaced with temperature radiant variable flow in the zone that there was "Zone HVAC Baseboard Rad Conv Water" - (on the tab HVAC systems) created 4 new plants loop, deleting the old plant loop - (on the tab schedule) created 8 new schedules for the new plant loop. the simulation failed and I tried to clear the two ventilation systems because I did not want to simulate this system. obviously the problem was not there, so the simulation failed again. can anyone help me? thank you very much

2017-11-21 10:22:11 -0500 received badge  Scholar (source)
2017-11-21 10:18:42 -0500 asked a question radiant floor simulation ok but wrong output

radiant floor simulation ok but wrong output I set the plant loop as the first two figure, the internal source

2017-11-21 04:53:40 -0500 received badge  Supporter (source)
2017-11-21 03:40:09 -0500 commented question failed openstudio simulation with low temp radiant variable flow

thanks avi. i've opened the file .err with notepad and i've seen that some surface with internal source haven't the same

2017-11-21 02:25:49 -0500 commented question failed openstudio simulation with low temp radiant variable flow

the file eplusout (file mtd) is empty. the other file eplusout (.err, .end, ...) i cant'open. only the file run because

2017-11-20 12:20:15 -0500 received badge  Student (source)
2017-11-20 12:18:49 -0500 asked a question failed openstudio simulation with low temp radiant variable flow

failed openstudio simulation with low temp radiant variable flow Hi, I'm just starting to learn openstudio so be patient

2017-11-20 08:37:48 -0500 commented question Radiator system doesn't operate correctly

nothing, i've solved. my model had too much internal loads. i lowered some parameters.

2017-11-16 11:10:34 -0500 commented question Radiator system doesn't operate correctly

Hi @simos @aparker, i've the same problem. How have you solved?