First time here? Check out the Help page!
2021-01-10 08:40:55 -0500 | received badge | ● Popular Question (source) |
2018-01-09 04:04:21 -0500 | commented answer | Ground temperature in openstudio yes i saw, but even if i impost none for all, it returns me error on surface |
2018-01-05 06:00:32 -0500 | commented answer | Ground temperature in openstudio I can not make it go. gives me errors: [12: 54: 53.930441 ERROR] Could not set argument 'footWallConstName' to value 'c |
2018-01-05 04:33:42 -0500 | commented answer | Ground temperature in openstudio not yet. I have to click on apply measure. create a new one from the template. and make a paste copy of the link code in |
2018-01-05 02:26:31 -0500 | commented answer | Ground temperature in openstudio the problem is created when I calculate the model without hvac systems. I have a supermarket as a model. 3 walls on 4 ag |
2018-01-05 02:14:14 -0500 | received badge | ● Commentator |
2018-01-05 02:14:14 -0500 | commented answer | Ground temperature in openstudio the problem is created when I calculate the model without hvac systems. I have a supermarket as a model. 3 walls on 4 ag |
2018-01-04 03:10:54 -0500 | asked a question | Ground temperature in openstudio Ground temperature in openstudio I wanted to change the ground temperature in openstudio. I saw in other posts that defa |
2017-12-06 11:18:52 -0500 | edited question | compressor setpoint temperature abnormal electrical consumption compressor setpoint temperature abnormal electrical consumption I set a waterheater heat pump combined with a low temper |
2017-12-06 11:17:12 -0500 | edited question | compressor setpoint temperature abnormal electrical consumption compressor setpoint temperature abnormal electrical consumption I set a waterheater heat pump combined with a low temper |
2017-12-06 11:17:12 -0500 | received badge | ● Editor (source) |
2017-12-06 11:15:35 -0500 | edited question | compressor setpoint temperature abnormal electrical consumption compressor setpoint temperature abnormal electrical consumption I set a waterheater heat pump combined with a low temper |
2017-12-06 11:11:37 -0500 | asked a question | compressor setpoint temperature abnormal electrical consumption compressor setpoint temperature abnormal electrical consumption I set a waterheater heat pump combined with a low temper |
2017-11-30 11:29:22 -0500 | asked a question | Curve Fit tool problem in data output Curve Fit tool problem in data output I used the spreadsheet, located in the energy plus installation folder, to calcula |
2017-11-30 11:17:22 -0500 | marked best answer | radiant floor simulation ok but wrong output I set the plant loop as the first two figure, the internal source as shown below, the setpoint manager like the following three figures. after running the simulation I have no fatal error and you can see a power consumption for heating, but looking at the indoor temperatures seems like nothing warms up. I'm sorry if i inserted too many images. someone has a suggestion to give me? |
2017-11-29 11:17:45 -0500 | commented question | radiant floor simulation ok but wrong output yes. thanks. now it's ok. |
2017-11-29 04:34:29 -0500 | commented question | radiant floor simulation ok but wrong output thnak you very much. i found it. i've never scroll in this tab. |
2017-11-28 10:12:39 -0500 | commented question | radiant floor simulation ok but wrong output but in openstudio where do I have to set these fields? |
2017-11-22 03:36:08 -0500 | commented question | radiant floor simulation ok but wrong output for information: the energy consumption is now half (58,2 kBtu) |
2017-11-22 03:26:53 -0500 | commented question | radiant floor simulation ok but wrong output I tried to delete the first three layers of the internal source and now it works. the internal temperatures follow the s |
2017-11-21 10:22:11 -0500 | marked best answer | failed openstudio simulation with low temp radiant variable flow Hi, I'm just starting to learn openstudio so be patient. I modeled a residential building with radiator system and the simulation was successful. then I wanted to simulate a radiant floor, and I used the measure "AedgOfficeHvacRadiantDoas". I've seen that the measure has changed some things: - created internal source (on the tab Constructions) that i've added in interior surface. - (on the tab thermal zone) replaced with temperature radiant variable flow in the zone that there was "Zone HVAC Baseboard Rad Conv Water" - (on the tab HVAC systems) created 4 new plants loop, deleting the old plant loop - (on the tab schedule) created 8 new schedules for the new plant loop. the simulation failed and I tried to clear the two ventilation systems because I did not want to simulate this system. obviously the problem was not there, so the simulation failed again. can anyone help me? thank you very much |
2017-11-21 10:22:11 -0500 | received badge | ● Scholar (source) |
2017-11-21 10:18:42 -0500 | asked a question | radiant floor simulation ok but wrong output radiant floor simulation ok but wrong output I set the plant loop as the first two figure, the internal source |
2017-11-21 04:53:40 -0500 | received badge | ● Supporter (source) |
2017-11-21 03:40:09 -0500 | commented question | failed openstudio simulation with low temp radiant variable flow thanks avi. i've opened the file .err with notepad and i've seen that some surface with internal source haven't the same |
2017-11-21 02:25:49 -0500 | commented question | failed openstudio simulation with low temp radiant variable flow the file eplusout (file mtd) is empty. the other file eplusout (.err, .end, ...) i cant'open. only the file run because |
2017-11-20 12:20:15 -0500 | received badge | ● Student (source) |
2017-11-20 12:18:49 -0500 | asked a question | failed openstudio simulation with low temp radiant variable flow failed openstudio simulation with low temp radiant variable flow Hi, I'm just starting to learn openstudio so be patient |
2017-11-20 08:37:48 -0500 | commented question | Radiator system doesn't operate correctly nothing, i've solved. my model had too much internal loads. i lowered some parameters. |
2017-11-16 11:10:34 -0500 | commented question | Radiator system doesn't operate correctly Hi @simos @aparker, i've the same problem. How have you solved? |