2024-04-08 08:17:40 -0500 | commented answer | Additional Lighting Power Allowance in new Appendix G @keigo - thanks for the reply. This was my concern as the limits listed in the 2022 are 0.4 / 0.7 / 1.0 vs 1.6 / 3.4 in |
2024-04-04 11:09:22 -0500 | asked a question | Additional Lighting Power Allowance in new Appendix G Additional Lighting Power Allowance in new Appendix G Seeking some clarification around Lighting Power Allowances for 90 |
2024-01-22 21:36:09 -0500 | marked best answer | OpenStudio IDF generation for EnergyPlus - Missing Headings? OpenStudio generates and idf which can be opened & simulated in EnergyPlus, no issue. The file can be opened/inspected with a text editor, also no issue. But when compared to an idf generated by EnergyPlus the 'headings' are missing. [!- ======== etc]. While not necessary for simulation, it seems odd to me. Is this something can be added or enabled? Have tried loading into EnergyPlus IDF editor and saving from there with 'sorted' in the 'saving options', but these are not added. It is highly useful for 'code folding' & navigation with a/the text editor. Thanks in advance |
2023-12-14 05:39:16 -0500 | received badge | ● Necromancer (source) |
2023-08-31 17:31:26 -0500 | asked a question | natural ventilation in ECB natural ventilation in ECB seeking others' experience when modeling natural ventilation in ECB/code compliance modeling. |
2023-08-30 10:37:47 -0500 | asked a question | CHPS daylighting in Climate Studio CHPS daylighting in Climate Studio Looking for some guidance around completing CHPS daylighting Climate Studio. Have fou |
2023-07-11 09:52:59 -0500 | asked a question | Design Builder ECB Baseline Design Builder ECB Baseline Design Builder has the capabilities to generate an Appendix G Baseline. However, it does n |
2023-06-27 14:25:44 -0500 | received badge | ● Notable Question (source) |
2023-06-27 14:25:44 -0500 | received badge | ● Popular Question (source) |
2023-05-17 06:38:32 -0500 | asked a question | ECB / CH11 Heat Pump Chiller ECB / CH11 Heat Pump Chiller Have a project pursuing Performance Compliance via Chapter/Section 11 compliance. The centr |
2023-03-08 06:24:17 -0500 | commented answer | DOE Reference Building - Supermarket I'd seen that referenced in the paper, but hadnt given it a try yet. Was more curious why this prototype would exist, bu |
2023-03-07 16:37:04 -0500 | edited question | DOE Reference Building - Supermarket DOE Reference Building - Supermarket Anyone know of / have the DOE Supermarket prototype results - or better know why it |
2023-03-07 16:36:42 -0500 | asked a question | DOE Reference Building - Supermarket DOE Reference Building - Supermarket Anyone know of / have the DOE Supermarket prototype results - or better know why it |
2022-12-06 16:28:24 -0500 | edited question | ECB/CH11 DOAS Systems Map ECB/CH11 DOAS Systems Map What has been others' experience with selecting DOAS units in the ECB/CH11 HVAC Systems Map? |
2022-12-06 16:27:24 -0500 | asked a question | ECB/CH11 DOAS Systems Map ECB/CH11 DOAS Systems Map What has been others' experience with selecting DOAS units in the ECB/CH11 HBAC Systems Map? |
2022-08-30 09:41:42 -0500 | received badge | ● Rapid Responder (source) |
2022-08-30 09:41:42 -0500 | answered a question | TMY3 or TMYx (or something else)? It largely depends on the effort. For LEED or Code compliance we've typically stuck to TMY3's as an 'official' source fo |
2022-08-16 08:45:46 -0500 | commented answer | radiant surface for both floor heating and cooling Design Builder did a demo/training on topics related to this last week (8/10/22), On the recording its about ~20min into |
2022-08-16 08:44:03 -0500 | commented answer | radiant surface for both floor heating and cooling Design Builder did a demo/training on topics related to this last week (8/10/22), On the recording its about ~20min into |
2022-07-01 08:18:51 -0500 | commented answer | ASHRAE 90.1 Addenda enforcement Thank you for clear & measured response. That all makes sense in the scheme of the authority being the enforcement m |
2022-06-30 16:35:25 -0500 | edited question | ASHRAE 90.1 Addenda enforcement ASHRAE 90.1 Addenda enforcement ASHRAE Standard 90.1 is a continuous maintenance standard. As such, there are on-going u |
2022-06-30 16:34:26 -0500 | asked a question | ASHRAE 90.1 Addenda enforcement ASHRAE 90.1 Addenda enforcement ASHRAE Standard 90.1 is a continuous maintenance standard. As such, there are on-going u |
2022-05-19 09:39:39 -0500 | received badge | ● Nice Answer (source) |
2022-05-19 09:39:39 -0500 | received badge | ● Enlightened (source) |
2022-05-09 09:26:39 -0500 | marked best answer | AIA2030 ZeroTool Does anyone know if there is a secret API for the AIA2030 ZeroTool? I haven't found anything in the documentation thus far, so figured I asked if anyone know of one. |
2022-05-06 10:09:55 -0500 | asked a question | AIA2030 ZeroTool AIA2030 ZeroTool Does anyone know if there is a secret API for the AIA2030 ZeroTool? I haven't found anything in the doc |
2021-11-10 05:24:22 -0500 | commented answer | Convert NOAA hourly normal CSV to EPW is this the " Passive Survivability, Resiliency and Modeling for the Future" session on Friday? |
2021-08-12 16:17:57 -0500 | edited question | multistack air to water heat Pump in eQuest multistack air-source in eQuest Have a model where a MultiStack Air-Source HP Chiller/Boiler is being considered. This u |
2021-08-12 16:17:21 -0500 | asked a question | multistack air to water heat Pump in eQuest multistack air-source in eQuest Have a model where a MultiStack Air-Source HP Chiller/Boiler is being considered. This u |
2021-08-05 17:15:24 -0500 | commented answer | Too many AHUs in the proposed model [beginner question] we commonly use this section to combine zones along a single thermal face. example is a row of closed offices with their |
2021-08-05 11:00:06 -0500 | commented answer | Too many AHUs in the proposed model [beginner question] If understanding you situation properky, then 'yes' that is a bunch of systems / huge model. I would give thought to d |
2021-08-05 08:29:10 -0500 | edited answer | Too many AHUs in the proposed model [beginner question] If there are repeating floor plates of same/similar lay out, then a floor multiplier could be used. This is especially h |
2021-08-05 08:27:58 -0500 | received badge | ● Rapid Responder (source) |
2021-08-05 08:27:58 -0500 | answered a question | Too many AHUs in the proposed model [beginner question] If there are repeating floor plates of same/similar lay out, then a floor multiplier could be used. This is especially h |
2021-05-14 19:53:52 -0500 | received badge | ● Popular Question (source) |
2021-03-23 13:57:33 -0500 | received badge | ● Popular Question (source) |
2021-02-18 09:08:26 -0500 | asked a question | LEEDv4 non-predominate system selection residential LEEDv4 non-predominate system selection residential LEEDv4 / ASHRAE 901.-2010 Appendix G model. Seeking some input on sy |
2020-12-14 17:18:49 -0500 | commented answer | eQUEST Batch Simulation Runs Digging way back...... The batch file creates the inp files at run time. The script above simulates already created inp |
2020-12-02 12:56:21 -0500 | received badge | ● Popular Question (source) |
2020-11-30 16:51:49 -0500 | asked a question | ASHRAE defined occupancy types ASHRAE defined occupancy types Can't seem to find if/where ASHRAE 90.1 has defined the Occupancy classifications for the |
2020-11-06 13:28:13 -0500 | answered a question | model maker is offline? is modelmaker still a thing or is that gone? |
2020-10-02 08:51:09 -0500 | commented answer | Equest novice questions on #4. It is possible to import just an inp file and create a model. eQuest will prompt for some additional info (weathe |
2020-09-11 13:23:40 -0500 | received badge | ● Popular Question (source) |
2020-08-13 17:37:51 -0500 | asked a question | eQuest/DOE CHW Thermal Storage kW shift eQuest/DOE CHW Thermal Storage kW shift Am working on a rather simple Chilled Water (CHW) Thermal Energy Storage (TES) S |