2019-10-17 11:57:52 -0500 | asked a question | Variable flow condenser loop (EnergyPlus) Variable flow condenser loop (EnergyPlus) Hi everyone. The model equips with 8 absorption chillers as 1 plant loop. Each |
2019-10-13 14:23:15 -0500 | asked a question | Condenser loop circulation even when the chiller doesn't work (EnergyPlus) Condenser loop circulation even when the chiller doesn't work (EnergyPlus) The model has 1 plant loop consisting of 8 ab |
2019-10-13 14:13:46 -0500 | marked best answer | Optimal operation of plant chillers (EnergyPlus) Hi! Now i am running a simulation of central plant system equipped with absorption chillers. The supply side has 3 chillers with headerd pump and common pipe. the following is the input parameter of the plant side system. i want each chiller to operate optimally with optimal part load ratio depending on the load(of course when multiple chillers operate, part load ratio could be below optimal PLR). so i expect that 'Pump Operating Pumps Count' should increase from 1 to 2, and from 2 to 3 depending on the load. but Pump Operating Pumps Count increases from 1 to 3 without being counted as 2. how can i control optimally these chillers? |
2019-10-13 14:13:33 -0500 | marked best answer | VAV system with constant air flow rate(EnergyPlus) Hi! now i am running a VAV system with EnergyPlus. i just found that the supply air is supplied in same flow rate constantly specially in summer. but it is weird that air supply flow rate changes variably in winter and spring what in this case, objects should i check for variable flow rates? |
2018-07-26 00:22:59 -0500 | asked a question | EnergyPlus: how to multiply energy use of air terminal when i apply zone group EnergyPlus: how to multiply energy use of air terminal when i apply zone group Hi now i am modelling high rise buildings |
2018-07-04 05:32:57 -0500 | received badge | ● Supporter (source) |
2018-07-04 05:32:51 -0500 | marked best answer | How can i fix supply air temperature for VRF in EnergyPlus? Hi! Now I am modelling a building equipped with VRF system. Even though generally supply air temperature of Japanese VRF is higher by 10 degrees Celcius than zone setpoint temperature, the model now i am modelling supplies in approximately 41 degrees Celcius. so i want to fix the VRF supply air temperature as 32 degrees celcius. how can i do this? i've already tried SetpointManager:FollowSystemNodeTemperature. but it didn't work. additionally, SetpointManager:Warmest and SetpointManager:WarmestTemperatureFlow don't work for VRF systems |
2018-07-04 05:32:32 -0500 | commented answer | How can i fix supply air temperature for VRF in EnergyPlus? thank you for your answer! i will try this! :) |
2018-07-03 02:36:51 -0500 | edited question | How can i fix supply air temperature for VRF in EnergyPlus? How can i fix supply air temperature for VRF in EnergyPlus? Hi! Now I am modelling a building equipped with VRF system. |
2018-07-03 02:36:09 -0500 | edited question | How can i fix supply air temperature for VRF in EnergyPlus? How can i fix supply air temperature for VRF in EnergyPlus? Hi! Now I am modelling a building equipped with VRF system. |
2018-07-03 02:35:49 -0500 | edited question | How can i fix supply air temperature for VRF in EnergyPlus? How can i fix supply air temperature for VRF in EnergyPlus? Hi! Now I am modelling a building equipped with VRF system. |
2018-07-03 02:31:49 -0500 | asked a question | How can i fix supply air temperature for VRF in EnergyPlus? How can i fix supply air temperature for VRF in EnergyPlus? Hi! Now I am modelling a building equipped with VRF system. |
2017-12-18 11:45:34 -0500 | asked a question | VAV system with constant air flow rate(EnergyPlus) VAV system with constant air flow rate(EnergyPlus) Hi! now i am running a VAV system with EnergyPlus. i just found that |
2017-11-06 01:15:49 -0500 | edited question | Optimal operation of plant chillers (EnergyPlus) Optimal operation of plant chillers (EnergyPlus) Hi! Now i am running a simulation of central plant system equipped with |
2017-11-06 01:15:36 -0500 | edited question | Optimal operation of plant chillers (EnergyPlus) Optimal operation of plant chillers (EnergyPlus) Hi! Now i am running a simulation of central plant system equipped with |
2017-11-06 01:15:36 -0500 | received badge | ● Editor (source) |
2017-11-06 01:14:56 -0500 | edited question | Optimal operation of plant chillers (EnergyPlus) Optimal operation of plant chillers (EnergyPlus) Hi! Now i am running a simulation of central plant system equipped with |
2017-11-06 01:14:21 -0500 | asked a question | Optimal operation of plant chillers (EnergyPlus) Optimal operation of plant chillers (EnergyPlus) Hi! Now i am running a simulation of central plant system equipped with |
2017-10-19 05:03:01 -0500 | commented answer | why negative internal convective heat gain during night?(EnergyPlus) Thank you very much! Actually after some investigations, i found that a curtain for shading causes negative internal gai |
2017-10-19 05:02:29 -0500 | commented answer | why negative internal convective heat gain during night?(EnergyPlus) Thank you very much! Actually after some investigations, i found that a curtain for shading causes negative internal gai |
2017-10-19 05:02:19 -0500 | commented answer | why negative internal convective heat gain during night?(EnergyPlus) Thank you very much! Actually after some investigations, i found that a curtain for shading causes negative internal gai |
2017-10-19 05:02:08 -0500 | commented answer | why negative internal convective heat gain during night?(EnergyPlus) Thank you very much! Actually after some investigations, i found that a curtain for shading causes negative internal gai |
2017-10-19 05:01:56 -0500 | commented answer | why negative internal convective heat gain during night?(EnergyPlus) Thank you very much! Actually after some investigations, i found that curtain for shading causes negative internal gains |
2017-10-19 05:01:38 -0500 | marked best answer | why negative internal convective heat gain during night?(EnergyPlus) Hello now i am checking the zone air heat balance for each zone. but i just found that the internal convective heat gain from perimeter zones have negative results during night in winter. actually, input/output reference describes internal convective heat gain rate as "The Zone Air Heat Balance Internal Convective Heat Gain Rate is the sum, in watts, of heat transferred to the zone air from all types of internal gains, including people, lights, equipment etc. This and the following provide results on the load components of the zone air heat balance. This field is not multiplied by zone or group multipliers." and i don't get how internal convective heat gain can have negative results. please teach me why this can be happened or what kinds of aspects are included in internal gains except people, lights, equipment. |
2017-10-19 05:01:38 -0500 | received badge | ● Scholar (source) |
2017-10-19 01:40:28 -0500 | commented answer | why negative internal convective heat gain during night?(EnergyPlus) Thank you very much! Actually after some investigations, i just found that curtain for shading causes negative internal |
2017-09-26 10:55:49 -0500 | received badge | ● Student (source) |
2017-09-26 08:59:48 -0500 | asked a question | why negative internal convective heat gain during night?(EnergyPlus) why negative internal convective heat gain during night?(EnergyPlus) Hello now i am checking the zone air heat balance f |