2020-10-01 18:33:40 -0500 marked best answer Why is the coil, chiller, tower oversized in Energy-Plus ?

The total cooling load of the entire facility is only 2700 kW, however the autosized design coil load is 8600 kW, the nominal capacity of the chiller and tower are 8600 and 8100 kW respectively. There is no sharp changes in design day schedule. Yet, how does this oversizing occur ?

2020-10-01 16:12:46 -0500 marked best answer Design day and Runperiod value mismatch

This particular CSV file (Please refer the image) was obtained from an EnergyPlus Simulation. The design day for this simulation is 05/21. The run period is also 05/21. Hence, both of them are same.

I take it that the variables in the upper half of the CSV file which is enclosed in a red box, corresponds to the design day values, and the rest belongs to run period.

So, I was wondering why they both are not the same ? eventhough my run period and design day are same!

image description

2019-05-30 14:20:45 -0500 marked best answer Can someone please provide me the steps for openstudio installation in Ubuntu 16.04 ?

Can someone please provide me the steps for openstudio installation in Ubuntu 16.04 ?

2018-10-15 20:25:32 -0500 marked best answer Difference Between Peak and Estimated Sensible Load

Someone please tell me what the Difference Between Peak and Estimated Sensible Load in the facilityloadcomponentsummary is ? what does the two terms mean ?

2018-10-01 12:55:40 -0500 received badge  Self-Learner (source)
2018-10-01 00:58:12 -0500 edited question Difference Between Peak and Estimated Sensible Load

Difference Between Peak and Estimated Sensible Load Someone please tell me what the Difference Between Peak and Estimate

2018-09-30 13:44:15 -0500 asked a question Difference Between Peak and Estimated Sensible Load

Difference Between Peak and Estimated Sensible Load Someone please tell me what the Difference Between Peak and Estimate

2018-09-29 04:47:54 -0500 edited question Repetitive models types

Redundant models types I was wondering why there many fan models eventhough they are the same ?

2018-09-29 04:46:26 -0500 asked a question Repetitive models types

Redundant models types I was wondering why there many fan models eventhough they are the same ?

2018-09-28 06:18:30 -0500 received badge  Teacher (source)
2018-09-28 04:03:41 -0500 answered a question Plant Loop:Demand Side is storing excess heat the majority of the time

I have resolved the error by setting the Reference Temperature Type = OutdoorAirDryBulb in the Setpoint manager FollowOu

2018-09-28 03:59:51 -0500 commented answer Cooling Coil has leaving humidity ratio > entering humidity ratio

I reduced the supply air temperature and the issue was resolved. Looks like I was doing something which was not psychrom

2018-09-28 03:59:02 -0500 marked best answer Cooling Coil has leaving humidity ratio > entering humidity ratio

Does anybody have an idea as to how this particular warning can be rectified or what causes this issue ?

SizeWaterCoil: Coil="CHW CLG COIL", Cooling Coil has leaving humidity ratio > entering humidity ratio.
   **   ~~~   **     Wair,in =  4.120009E-003
   **   ~~~   **     Wair,out = 8.912150E-003
   **   ~~~   ** ....coil leaving humidity ratio will be reset to:
   **   ~~~   **     Wair,out = 4.120009E-003
2018-09-28 02:13:32 -0500 asked a question Energyplus : Calculation of cooling coil design UA failed for coil CHW CLG COIL

Energyplus : Calculation of cooling coil design UA failed for coil CHW CLG COIL Can anyone please tell me why this error

2018-09-28 00:17:32 -0500 asked a question Cooling minimum air flow fraction ?

Cooling minimum air flow fraction ? Will the Sizing:Zone:Cooling Minimum Air Flow Fraction input still be used to set mi

2018-09-27 23:11:25 -0500 commented answer Chiller curve and AHRI test condition.

My chiller is a water cooled chiller. I changed the Xmin, Xmax to 7, Ymin and Ymax values to 19 and 30 but still the er

2018-09-27 23:10:48 -0500 edited question Plant Loop:Demand Side is storing excess heat the majority of the time

Plant Loop:Demand Side is storing excess heat the majority of the time How to rectify the error "Plant Loop:Demand Side

2018-09-27 23:09:37 -0500 edited question Plant Loop:Demand Side is storing excess heat the majority of the time

Plant Loop:Demand Side is storing excess heat the majority of the time How to rectify the error "Plant Loop:Demand Side

2018-09-27 23:09:28 -0500 commented question Plant Loop:Demand Side is storing excess heat the majority of the time

I have posted the picture on top and yeah I have tried using intermittent pump setting also.

2018-09-27 23:03:30 -0500 marked best answer water heater sizing object missing in OpenStudio

I am trying to add a water heater and I am trying to autosize the heater maximum capacity but it says

Warning ** Water heater named WATER HEATERhas heater capacity set to AUTOSIZE but it is missing associated WaterHeater:Sizing object
   **  Fatal  ** GetWaterThermalTankInput: Errors found in getting thermal storage input. Preceding condition(s) causes termination.

However, the fatal error disappears when I hardsize the heater maximum capacity. I believe this is a OpenStudio bug, can anyone clarify ?

image description

2018-09-27 07:46:53 -0500 commented answer Chiller curve and AHRI test condition.

My chiller is a water cooled chiller. I changed the Xmin, Xmax to 7 Ymin and Ymax values to 19 and 30 but still the err

2018-09-27 07:46:41 -0500 edited question Chiller curve and AHRI test condition.

Chiller curve and AHRI test condition. Hi It looks like the IPLV calculated for my chiller is not at AHRI test conditio

2018-09-27 07:46:04 -0500 commented answer Chiller curve and AHRI test condition.

My chiller is a water cooled chiller. I changed the Xmin, Xmax to 7 Ymin and Ymax values to 19 and 30 but still the err

2018-09-27 05:40:27 -0500 asked a question water heater sizing object missing in OpenStudio

water heater sizing object missing in OpenStudio I am trying to add a water heater and I am trying to autosize the heate

2018-09-27 04:51:39 -0500 commented answer Air volume flow rate per watt of rated total cooling capacity is out of range at 6.741E-005 m3/s/W

I understand, however how does the warning not appear when I change the setpoint manager to "Setpoint Manager Single Zo

2018-09-27 04:51:26 -0500 commented answer Air volume flow rate per watt of rated total cooling capacity is out of range at 6.741E-005 m3/s/W

I understand, however how does it not appear when I change the setpoint manager to "Setpoint Manager Single Zone One St

2018-09-26 23:02:34 -0500 commented question Cooling Tower is storing excess heat the majority of the time

Is the issue resolved ?

2018-09-26 23:02:26 -0500 commented question Cooling Tower is storing excess heat the majority of the time

Yeah, is the issue resolved ?

2018-09-26 22:46:44 -0500 commented question Plant Loop:Demand Side is storing excess heat the majority of the time

My pump is continuous, I have included images of the pump settings and the loop settings

2018-09-26 22:46:28 -0500 edited question Plant Loop:Demand Side is storing excess heat the majority of the time

Plant Loop:Demand Side is storing excess heat the majority of the time How to rectify the error "Plant Loop:Demand Side

2018-09-26 22:46:26 -0500 commented question Plant Loop:Demand Side is storing excess heat the majority of the time

My pump is continous

2018-09-26 22:39:40 -0500 commented question SketchUp stuck after surface matching

It got resolved, I just had to wait for sometime.

2018-09-26 04:00:04 -0500 asked a question SketchUp stuck after surface matching

SketchUp stuck after surface matching I tried to create three floors separately and I moved them on top of each other. W

2018-09-24 03:49:52 -0500 received badge  Enthusiast
2018-09-23 23:29:47 -0500 asked a question Cooling Coil has leaving humidity ratio > entering humidity ratio

Cooling Coil has leaving humidity ratio > entering humidity ratio Does anybody have an idea as to how this particular

2018-09-23 23:00:04 -0500 asked a question Plant Loop:Demand Side is storing excess heat the majority of the time

Plant Loop:Demand Side is storing excess heat the majority of the time How to rectify the error "Plant Loop:Demand Side

2018-09-21 03:17:11 -0500 commented question How do I sign up in Unmet Hours

I am sorry, this can be deleted. I was kinda making a presentation regarding how to sign up for Unmet hours.

2018-09-20 22:54:37 -0500 commented answer Frame and divider does not get added

done...………………….

2018-09-20 22:54:24 -0500 marked best answer Frame and divider does not get added

I am trying to add frame and divider property to my sub surfaces, yet when i click on apply to selected, it vanishes off. Can some help ?

image description

2018-09-20 22:54:03 -0500 asked a question How do I sign up in Unmet Hours

How do I sign up in Unmet Hours Hi, this is just a sample question. The context of your problem can be described here. P