2024-02-27 10:43:47 -0500 commented answer How can I model and integrate custom loads/systems in E+

Hi there, some years later, I am facing the same issue. However, putting the Schedule:File in the same folder as the .id

2024-02-27 10:40:30 -0500 commented question Schedule File in FMU Resource

Hi there, some years later, I am facing the same issue. However, putting the Schedule:File in the same folder as the .id

2024-02-27 10:39:34 -0500 answered a question Schedule File in FMU Resource

Hi there, some years later, I am facing the same issue. However, putting the Schedule:File in the same folder as the .id

2023-01-30 08:24:59 -0500 answered a question How can I make ESP-r run without crashing?

What Windows version of ESP-r? Basically, the Windows version has been dormant for quite some time and only recently re-

2023-01-30 08:18:54 -0500 answered a question How can I add thermal resistance in ESR-r?

Hi there, when editing the materials database, in the 'categories' you find "GAPS". This refers to air layers. When def

2022-11-17 04:35:20 -0500 edited answer IGDB historical versions, data access

Q1: Via change-logs (currently https://windows.lbl.gov/sites/default/files/software/IGDB/IGDBReleaseNotes-88.htm) the hi

2022-11-17 04:31:39 -0500 edited answer IGDB historical versions, data access

Q1: Via change-logs (currently https://windows.lbl.gov/sites/default/files/software/IGDB/IGDBReleaseNotes-88.htm) the hi

2022-11-17 04:31:02 -0500 answered a question IGDB historical versions, data access

Q1: Via change-logs (currently https://windows.lbl.gov/sites/default/files/software/IGDB/IGDBReleaseNotes-88.htm) the hi

2022-11-15 01:04:17 -0500 commented answer IGDB historical versions, data access

Hi Matthew, thanks for your reply. I haven't tried anything yet in regard to opening historic database files. If simply

2022-11-15 01:02:52 -0500 received badge  Supporter (source)
2022-11-15 01:02:49 -0500 commented answer IGDB historical versions, data access

Hi Matthew, thanks for your reply. In regard to actually getting the data from historic database files, I haven't tried

2022-11-11 14:47:40 -0500 asked a question IGDB historical versions, data access

IGDB historical versions, data access Dear Community, the IGDB has been around for quite a while. In context with a pro

2022-09-13 09:05:31 -0500 commented answer Large model modelling

Again, what are you looking for in the end? For an apartment building with 21 levels, I would expect that 19 levels are

2022-09-13 09:05:31 -0500 received badge  Commentator
2022-09-13 04:18:56 -0500 received badge  Teacher (source)
2022-09-10 11:37:40 -0500 answered a question Large model modelling

Basically IMO it very much depends on what the goal of your model is. Are you looking at/for "whole building information

2022-09-01 01:34:10 -0500 commented answer EnergyPlus setting heat transfer algorithm for constructions - leads to fatal error

I submitted issue #9632.

2022-08-31 10:34:33 -0500 commented answer EnergyPlus setting heat transfer algorithm for constructions - leads to fatal error

Sadly it seems no. Regex only seem possible in the "first" category, i.e. here the surface name. Not in the variable nam

2022-08-31 08:58:26 -0500 marked best answer EnergyPlus setting heat transfer algorithm for constructions - leads to fatal error

Hi there,

does anyone have experience in setting the heat transfer algorithm of selected constructions? According to the IO-Manual, I can set the global behaviour via

HeatBalanceAlgorithm, ConductionTransferFunction, 200; !- Algorithm, Surface Temperature Upper Limit {C}

and can then change this for selected constructions like this,

SurfaceProperty:HeatTransferAlgorithm:Construction, BO05Override, ConductionFiniteDifference, BO05; !- Name, Algorithm, Construction Name

Seems easy & straightforward. However, I then get a fatal error when trying to run the simulation telling me that "InitialInitHeatBalFiniteDiff: Found Material that is too thin and/or too highly conductive ..." which gives a material name that is not part of the construction addressed.

Any ideas welcome. Best Achim

OS: macOS; EnergyPlus, Version 22.1.0-43b09606e2

2022-08-31 08:58:26 -0500 received badge  Scholar (source)
2022-08-31 08:58:21 -0500 commented answer EnergyPlus setting heat transfer algorithm for constructions - leads to fatal error

Workaround suggested works fine. Thanks again (by the way, the original "culprit" material was a sheet metal, not an air

2022-08-30 02:06:14 -0500 commented answer I am trying to model a framed wall. can anyone please explain how this type of wall is modeled in energyplus? please see attached pic for reference. This is a traditional wall found in the Himalayan region made of stone, rubble and wooden frames.

I would second the described approach, likely values for thermal conduction can be tweaked/adapted by using the "mixed l

2022-08-15 15:28:22 -0500 received badge  Student (source)
2022-08-11 07:20:50 -0500 commented question EnergyPlus setting heat transfer algorithm for constructions - leads to fatal error

Hi Scott, thanks again, finally I found time to re-compile the current version of E+ (there seemed to be some commits in

2022-07-27 03:06:53 -0500 commented question EnergyPlus setting heat transfer algorithm for constructions - leads to fatal error

Hi Scott, thanks for taking notice. The .idf should be downloadable from here for a few days: https://drive.switch.ch/in

2022-07-26 09:05:20 -0500 edited question EnergyPlus setting heat transfer algorithm for constructions - leads to fatal error

EnergyPlus setting heat transfer algorithm for constructions - leads to fatal error Hi there, does anyone have experien

2022-07-26 08:55:48 -0500 edited question EnergyPlus setting heat transfer algorithm for constructions - leads to fatal error

EnergyPlus setting heat transfer algorithm for constructions - leads to fatal error Hi there, does anyone have experien

2022-07-26 08:55:18 -0500 received badge  Editor (source)
2022-07-26 08:55:18 -0500 edited question EnergyPlus setting heat transfer algorithm for constructions - leads to fatal error

EnergyPlus setting heat transfer algorithm for constructions - leads to fatal error Hi there, does anyone have experien

2022-07-26 08:54:41 -0500 asked a question EnergyPlus setting heat transfer algorithm for constructions - leads to fatal error

EnergyPlus setting heat transfer algorithm for constructions - leads to fatal error Hi there, does anyone have experien

2022-05-05 06:44:40 -0500 commented answer Can we use epjson as input file to run energy simulation?

Hi, this Q/A is somewhat old, but I expect it is still basically true (except that there is a new option --convert_only

2022-05-05 06:42:25 -0500 commented answer Can we use epjson as input file to run energy simulation?

Hi, this Q/A is somewhat old, but I expect it is still basically true (except that there is a new option --convert_only

2021-11-01 13:32:31 -0500 answered a question Overview of BEM softwares that are more detailed than EnergyPlus

FWIW, ESP-r is maintained. I.e., there is a new version approx. twice a year and basically one can reach out to ESRU.

2021-08-12 10:18:56 -0500 commented answer How to set different working directories for parallel simulations?

Thank you, Thierry! That helped a lot, now the "parallel run of two instances problem" also seems to be solved. A small

2021-08-11 12:10:48 -0500 commented answer How to set different working directories for parallel simulations?

Hi there, @scrox, have you made any progress here? I am currently having the same issue and would be interested in any u