2020-09-16 02:51:34 -0500 | received badge | ● Popular Question (source) |
2020-06-24 16:02:21 -0500 | received badge | ● Popular Question (source) |
2017-10-04 03:30:37 -0500 | marked best answer | how to set air infiltration under 50 pa pressure I am doing a passive house model, the required airtightness is less than 0.6 ACH at 50 pa difference. In Opensutdio, in space infiltration design flow rate rates, i can set 0.6 air changes per hour but the question is how to set 50 Pascal pressure difference? |
2017-10-04 03:30:00 -0500 | marked best answer | Temperature inside and outside the model In my project, I need to find out the temperature variation in the model corresponding to outside temperature based on heavy-weight and light-weight construction. But in Openstudio, we need to set the cooling thermostat and heating thermostat, which controls the temperature in the building, otherwise, the simulation will fail. So how can I find out the temperature variation in the model without setting the thermostat? |
2017-10-04 03:28:20 -0500 | commented answer | Humidity control Thanks for the reply! I also have the same problem. In the HVAC system, there is no dehumidifier to be selected. So I a |
2017-09-28 02:29:54 -0500 | asked a question | Humidity control Humidity control I am doing a single thermal zone model in Openstudio. I have added a packaged roof heat pump system wit |
2017-09-25 21:32:01 -0500 | commented answer | how to change the Y-axis scale in ResultsViewer But, OS v.2.3.0 is not released, is it? |
2017-09-24 08:42:20 -0500 | commented question | how to allow natural ventilation at night and turn on cooling system during the day in summer Hi, I am using Openstudio. |
2017-09-21 08:00:41 -0500 | asked a question | how to allow natural ventilation at night and turn on cooling system during the day in summer how to allow natural ventilation at night and turn on cooling system during the day in summer Could anyone tell me that |
2017-09-21 04:33:15 -0500 | asked a question | how to change the Y-axis scale in ResultsViewer how to change the Y-axis scale in ResultsViewer Could any tell me how to change the Y-axis scale in Openstudio ResultsVi |
2017-09-13 09:46:59 -0500 | asked a question | parametric analysis tool parametric analysis tool I wanted to do some analysis on the window-wall ratio in the parametric analysis tool. When I a |
2017-09-13 03:12:58 -0500 | asked a question | Temperature inside and outside the model Temperature inside and outside the model In my project, I need to find out the temperature variation in the model corres |
2017-09-13 02:57:04 -0500 | marked best answer | Resistance of wall I have created a wall in Openstudion which comprises several materials, I calculated the R-value of each material and sum them up to calculate the total R-value and U-value, then I found that the U-value that I have got is exactly the same as the U-value in the Eneregyplus result, which means the materials are in series. So the question is how to create a wall which has several materials in parallel? |
2017-09-13 02:57:03 -0500 | received badge | ● Scholar (source) |
2017-09-12 08:18:24 -0500 | asked a question | Resistance of wall Resistance of wall I have created a wall in Openstudion which comprises several materials, I calculated the R-value of |
2017-09-12 07:28:48 -0500 | commented answer | how to set air infiltration under 50 pa pressure Thanks for your comment! So if the n-factor is 10, then the air infiltration rate is 0.06 ACHnat? |
2017-09-11 10:51:57 -0500 | received badge | ● Student (source) |
2017-09-10 15:12:10 -0500 | asked a question | how to set air infiltration under 50 pa pressure how to set air infiltration under 50 pa pressure I am doing a passive house model, the required airtightness is less tha |