First time here? Check out the Help page!
2023-02-01 09:56:14 -0500 | received badge | ● Popular Question (source) |
2023-02-01 09:56:14 -0500 | received badge | ● Notable Question (source) |
2020-11-12 11:56:00 -0500 | received badge | ● Popular Question (source) |
2020-06-23 08:39:33 -0500 | asked a question | PCM embed in the windows PCM embed in the windows hi, is there any way to embed phase change material in the windows? I know PCM can only b |
2020-04-24 10:39:24 -0500 | asked a question | Radiant ceiling add doas - energyplus Radiant ceiling add doas - energyplus Does anyone know how to set up this kind of system? Thanks in advance ! |
2020-01-18 07:39:30 -0500 | commented answer | how to simulate movable roof shading It seems I have to add a window glass and then can use the shading control schedule.Thank you for your help. |
2020-01-17 10:00:03 -0500 | asked a question | how to simulate movable roof shading how to simulate movable roof shading Dear all, I want to add a movable shading on the roof, please see the pi |
2019-12-24 09:53:36 -0500 | asked a question | how to control roller blind shading how to control roller blind shading hello, I want to build a single model with roller blind and try to use Win |
2019-12-08 05:01:21 -0500 | commented question | FCU+DOAS OA Problem it is strange that "max air flow" of FCU and DOAS always same with my OA value, what's the problem? |
2019-12-05 06:22:12 -0500 | answered a question | FCU+DOAS OA Problem it is strange that "max air flow" of FCU and DOAS always same with my OA value, what's the problem? |
2019-12-05 06:06:12 -0500 | asked a question | FCU+DOAS OA Problem FCU+DOAS OA Problem hi all, I'm working on a FCU+DOAS Template.I set the Designspecification:Outdoorair (1m3/s). crea |
2019-03-21 17:25:39 -0500 | commented answer | how to control DOAS supply fan and damper? yes, I want to simulate a full fresh air system, I will try your suggestion. thank you! |
2019-03-20 10:52:22 -0500 | commented answer | how to control DOAS supply fan and damper? is there any way I can send the idf to you? |
2019-03-20 10:51:11 -0500 | commented answer | how to control DOAS supply fan and damper? yes, I set two systems. FCU+DOAS, FCU deal with Zone load, and DOAS system deal with OA load, I checked FCU Mixing box, |
2019-03-20 09:57:57 -0500 | commented answer | how to control DOAS supply fan and damper? it's very strange that I checked the system node of outdoor air node and air terminal unit, they are worked as schedule, |
2019-03-20 09:37:32 -0500 | commented answer | how to control DOAS supply fan and damper? how can I send you my idf file? can you leave a mail address? |
2019-03-19 09:16:30 -0500 | asked a question | confuse with air flow rate in air loop hvac confuse with air flow rate in air loop hvac I simulated a full fresh air system. when I check the air flow of system nod |
2019-03-19 08:52:23 -0500 | received badge | ● Commentator |
2019-03-19 08:52:23 -0500 | commented answer | how to control DOAS supply fan and damper? As I know, availability schedule can only realize on/off, what if I want to simulate the 0~1 fraction schedule? |
2019-03-16 18:04:09 -0500 | commented answer | energyplus heating and cooling load ok, I have a DOAS terminal (AirTerminal:SingleDuct:VAV:NoReheat), but how can I set OA to this terminal? I find no OA se |
2019-03-16 10:19:24 -0500 | commented question | energyplus heating and cooling load yes, I add the OA flow rate in the HVACTemplate:Zone:FanCoil,, because I'm not sure how to add OA flow rate directly int |
2019-03-16 10:15:39 -0500 | commented question | energyplus heating and cooling load yes, I add the OA flow rate in the FCU, because I'm not sure how to add OA flow rate directly in the DOAS system. my in |
2019-03-16 10:14:09 -0500 | commented question | energyplus heating and cooling load yes, I add the OA flow rate in the FCU, because I'm not sure how to add OA flow rate directly in the DOAS system. my in |
2019-03-15 04:30:09 -0500 | asked a question | energyplus heating and cooling load energyplus heating and cooling load I'm working on FCU + DOAS system, I find that if I increase the outdoor air Volume., |
2019-03-15 03:57:39 -0500 | asked a question | how to control DOAS supply fan and damper? how to control DOAS supply fan and damper? Hi everyone, I'm simulating FCU + DOAS system in energyplus, when I get the r |
2018-10-08 01:39:05 -0500 | commented answer | outdoor air control strategy thank you for your help!o( ̄▽ ̄)d |
2018-09-19 04:49:47 -0500 | commented question | outdoor air control strategy and how to control the exhaust air volume and schedule? |
2018-09-19 04:39:39 -0500 | asked a question | outdoor air control strategy outdoor air control strategy I'm modeling a lab by E+. I need to consider fume hood exhaust and air change rate and the |
2018-03-12 21:24:53 -0500 | received badge | ● Popular Question (source) |
2018-03-06 09:02:00 -0500 | asked a question | supply air temperature and humidity supply air temperature and humidity hi all, I have a question. can anybody help me to solve it? I want to simulate a ful |
2018-01-23 03:34:45 -0500 | asked a question | Cooling and Heating sch Cooling and Heating sch I have a question about the Cooling and Heating sch. my setting is: from Monday to Friday. the t |
2018-01-16 04:43:53 -0500 | marked best answer | ideal air load not reasonable I find that the ideal air load result is very low, about 70w/m2 or less. How do you deal with this problem? anyone can help? How can I find the total heat load? someone said ventilation load isn't taken into account when running the ideal air load, I tried "design specification outdoor air", "space infiltration air flow rate" and "zone ventilation air flow rate", but cannot add the ventilation load. |
2018-01-02 01:26:59 -0500 | received badge | ● Enthusiast |
2018-01-02 01:26:59 -0500 | received badge | ● Enthusiast |
2018-01-01 08:23:58 -0500 | asked a question | zone control thermostat - cooling autosize doesn't work zone control thermostat - cooling autosize doesn't work hi all, I have made an energyplus model, When I see the |
2017-12-07 10:24:35 -0500 | answered a question | Why energy consumption is not proportional with Outdoor air @rraustad I checked the air system outdooor air mass flow rate. when I enter 1m3/s the result shows 1.203523625 kg/s |
2017-11-29 09:23:07 -0500 | commented answer | Zone Ventilation I have write an email to you, but the email is rejected. can you tell me your e-mail address or you can send me an emai |
2017-11-03 08:46:25 -0500 | commented answer | Zone Ventilation thank you, I used this way to calculate. I tried this way to compare the outdoor air energy consumption. but I find a pr |
2017-11-03 08:37:38 -0500 | asked a question | Outdoor air load no return air Outdoor air load no return air hi,does anyone who can help me to solve this problem? I confused for a long time. how to |
2017-11-01 02:23:02 -0500 | commented question | Why energy consumption is not proportional with Outdoor air I spend a long time, but didn't solve it. appreciate if you can tell me the right way |
2017-11-01 02:15:49 -0500 | commented question | Why energy consumption is not proportional with Outdoor air so how can I simulate it? do you have a good way to simulate the same room with 2m3/s, 3m3/s, 4m3/s, 5m3/s...outdoor air |
2017-10-26 21:37:00 -0500 | asked a question | Why energy consumption is not proportional with Outdoor air Why energy consumption is not proportional with Outdoor air hello, can anyone help to solve this problem? I struggled fo |
2017-10-23 04:57:34 -0500 | asked a question | energy consume for 100% outdoor air energy consume for 100% outdoor air I have built a model to simulate the energy consume of 100% outdoor air. after I fin |
2017-10-16 11:57:34 -0500 | received badge | ● Teacher (source) |
2017-10-16 09:15:31 -0500 | answered a question | how to select Space type and climate zone I Just use "CHN_Shanghai.Shanghai.583620_CSWD.ddy" office-90.1 2010 template-ASHRAE 169-2006-2B space type use ASHRAE 9 |
2017-10-15 20:39:39 -0500 | asked a question | Part-load ratio heating control failed Part-load ratio heating control failed I have a question, How to deal with it? * Warning * Part-load ratio heating co |
2017-09-28 09:54:12 -0500 | asked a question | how to select Space type and climate zone how to select Space type and climate zone I have a question, if I want to simulate the building in ShangHai (China). How |
2017-09-26 04:56:43 -0500 | asked a question | why Sensible Cooling load become smaller after add AC system? why Sensible Cooling load become smaller after add AC system? I have a question. when I finished my building model and |
2017-09-05 00:20:59 -0500 | asked a question | Zone Ventilation Zone Ventilation Hello, I'd like to build 2 models, one with 1000m3/h Fresh air, another with 0 air flow. I want to comp |
2017-08-30 03:53:56 -0500 | asked a question | ideal air load not reasonable ideal air load not reasonable I find that the ideal air load result is very low, about 70w/m2 or less. how do you deal w |