First time here? Check out the Help page!
2023-03-09 09:11:05 -0500 | asked a question | Cooling coil of Unitary System doesn't follow setpoint Cooling coil of Unitary System doesn't follow setpoint Hello. I built an idf file in energyplus v22.2 to simulate a cool |
2022-06-29 02:17:50 -0500 | commented answer | VRF performance curve: EIR modifier for PLR > 1 Thank you very much for your answer. I have the same kind of graph shown in Figure 8, but in my case the power consumpti |
2022-06-28 08:27:19 -0500 | asked a question | VRF performance curve: EIR modifier for PLR > 1 VRF performance curve: EIR modifier for PLR > 1 The VRF curve system model in energyplus has a specific performance c |
2021-10-06 05:27:19 -0500 | edited question | Energyplus version 9.6 can't run on Windows 7 Energyplus version 9.6 can't run on Windows 7 I can't run the new EnergyPlus version 9.6 in several computers that use W |
2021-10-06 04:22:58 -0500 | edited question | Energyplus version 9.6 can't run on Windows 7 Energyplus version 9.6 supported OS I can't run the new EnergyPlus version 9.6 in several computers that use Windows 7 w |
2021-10-06 04:22:25 -0500 | asked a question | Energyplus version 9.6 can't run on Windows 7 Energyplus version 9.6 supported OS I can't run the new EnergyPlus version 9.6 in several computers that use Windows 7 w |
2021-07-01 01:15:41 -0500 | marked best answer | Differences in results between EnergyPlus 9.3 and 9.4 I found significant differences in the results of energy use of a simple building between EnergyPlus 9.3 and 9.4. The differences are related with the windows, since the same building without windows shows negligible differences between versions. I use the WindowMaterial:SimpleGlazingSystem, so I guess the differences come from this issue (https://github.com/NREL/EnergyPlus/pu...). My building is just a 10x10m square containing an Ideal Loads Air System. The "District Heating energy use" decreases from version 9.3 to 9.4 between 0.7% and 8.8% depending on the size, orientation and shading of the windows. While the "District Cooling energy use" increases between 0.8 and 3.8%. Differences are bigger when the building "gets more sun" (= south-facing windows, larger windows, less shading). When I add a WindowShadingControl with the option ExteriorShade, there are practically no differences in the results, as in the case without windows. My question is: is this the expected behavior of the WindowMaterial:SimpleGlazingSystem after the fix #8001? Or should I change any parameters related to the windows to keep them working as before? I used the transition tool to get the idf files for both versions 9.3 and 9.4, from version 9.1 (I was actually comparing v9.1 with v9.5 but I located the relevant differences between versions 9.3 and 9.4). |
2021-06-30 06:34:35 -0500 | asked a question | Differences in results between EnergyPlus 9.3 and 9.4 Differences in results between EnergyPlus 9.3 and 9.4 I found significant differences in the results of energy use of a |
2020-03-10 07:26:43 -0500 | commented answer | E+, defining DOAS fan specifications according to manufacturer's book Sorry for the delay, I hadn't seen your comment. Probably you already found the formula. At that time, I was using Energ |
2019-11-05 09:34:32 -0500 | received badge | ● Enthusiast |
2019-10-31 03:04:13 -0500 | marked best answer | HeatPump:WaterToWater:EIR models' curves report wrong values I'm using the water-to-water heat pump models HeatPump:WaterToWater:EIR:Heating and Cooling in simple hot and chilled water loops connected to a fancoil. The water temperatures and mass flow rates in both loop nodes look fine. I got good values for the outputs of the heat pump when I used the constant performance curves in the example file for this model. But when I have started using curves with values, I have started having a mess with the model results. EDIT: From the results I detailed below, I think that the model is using the EIRFT curve to get both the "EIR-function of temperatures" and "EIR-function of PLR" modifiers. Then in the curve output variables I can only see the last action performed (to get the EIRFPLR modifier). Then, if I prepare an EIRFT table with the PLR and Outlet hot water temperatures in the x axis, I can get the expected heat pump power consumption results. Can anyone confirm this please? I am really interested in using this heat pump model. The EIR modifier function of temperature curve (EIRFT) The EIRFT curve should use the Outlet hot/chilled water temperature as "Input variable 1". However, when I look at the output variable "Performance Curve Input Variable 1 Value" for this curves, I'm not obtaining the expected value. I think this curve is getting as input the PLR value instead. Although the water-to-water heat pump PLR is not available for reporting, the value I'm getting as "input variable 1" matches "PLR=Load Side Heat Transfer Rate / (Reference Capacity*CAPFT)". The "Performance Curve Input Variable 2 Value" output works well, and the curve output is consistent with the reported input values. The EIR modifier function of PLR curve (EIRFPLR) I get 0 as both input and output value when I report the curve output variables. I make changes in this curve and the heat pump outputs (electric power and source side heat transfer rate) remain the same although the heat pump isn't working at full load (PLR<1). The model equations I couldn't find the model equations in the Engineering Reference Manual for this object. I guess they are the same as the EIR-based chiller model: I couldn't actually check whether I'm getting consistent results, because the reported "EIRFPLR" output value is 0. However I have all the other values, so I tried to solve for it. The EIRFPLR value I found turned out to be exactly the expected EIRFT value for the correct input variables (not the reported ones). Error with EIRFT table dimensions and transition version Maybe this other issue is related. In version 9.1 this heat pump model accepted a "Table:TwoIndependentValues" object as EIRFT curve. In version 9.2, it doesn't accept the equivalent "Table:Lookup" object with two independent variables (although ... (more) |
2019-10-17 10:21:22 -0500 | edited question | HeatPump:WaterToWater:EIR models' curves report wrong values HeatPump:WaterToWater:EIR models' curves report wrong values I'm using the water-to-water heat pump models HeatPump:Wate |
2019-10-16 12:01:25 -0500 | asked a question | HeatPump:WaterToWater:EIR models' curves report wrong values HeatPump:WaterToWater:EIR models' curves report wrong values I'm using the water-to-water heat pump models HeatPump:Wate |
2019-10-16 09:16:40 -0500 | edited question | EnergyPlus version transition Rules 9.1 to 9.2 EnergyPlus version transition Rules 9.1 to 9.2 I downloaded the new EnergyPlus 9.2 version and I can't find the file cal |
2019-10-16 08:29:29 -0500 | commented answer | EnergyPlus version transition Rules 9.1 to 9.2 Thank you very much! |
2019-10-16 08:29:13 -0500 | marked best answer | EnergyPlus version transition Rules 9.1 to 9.2 I downloaded the new EnergyPlus 9.2 version and I can't find the file called "Rules9-1-to-9-2.md" that used to come with the older versions. This file was really useful since it explained all the objects with changes in the IDF file. I haven't found any other file with similar information. Do you know if this file is available anywhere else, or if is there any other place where these rules can be looked at? Thank you |
2019-10-16 06:46:23 -0500 | asked a question | EnergyPlus version transition Rules 9.1 to 9.2 EnergyPlus version transition Rules 9.1 to 9.2 I downloaded the new EnergyPlus 9.2 version and I can't find the file cal |
2019-10-08 05:18:25 -0500 | answered a question | Water-to-Water Heat Pump Component Not Working I had a similar problem with the HeatPump:WaterToWater:Heating:EIR component of Energyplus 9.1. I had a very simple hot |
2019-05-16 05:30:18 -0500 | commented question | Water cooling coil design inputs In the situation I described the fan coil fan is already hard-sized, with the same design air flow rate as the cooling c |
2019-04-24 07:33:12 -0500 | commented question | Water cooling coil design inputs In the HTML outputs report, section HVAC Sizing Summary -> Coil Sizing Summary, there is the value of the "Reference |
2019-04-17 11:18:29 -0500 | commented question | HVACTemplate:System:ConstantVolume minimum outdoor air schedule doesn't work This issue has been fixed in EnergyPlus v9.1 |
2019-04-15 09:28:48 -0500 | received badge | ● Popular Question (source) |
2019-04-10 02:17:45 -0500 | asked a question | Water cooling coil design inputs Water cooling coil design inputs Hi! I am trying to define a specific fancoil in EnergyPlus v9.1. I am seting all the in |
2019-01-18 07:52:50 -0500 | answered a question | E+, defining DOAS fan specifications according to manufacturer's book According to the Engineering Reference Manual (p.1044), the electric consumption of the fan is calculated as: Rated ele |
2019-01-15 01:36:59 -0500 | marked best answer | VRF performance curve: EIR boundary temperature I tried a simple case of VRF system with EnergyPlus v9.0. I reported the outputs "Performance Curve Input /Output Value" for the VRF model performance curve called "Cooling Energy Input Ratio Boundary Curve", which gave me a result of -999. However, the rest of the cooling curves have good values. In fact, the selection between the low and high cooling EIR curve seems to be following the boundary temperature curve for cooling capacity, not for EIR. Can anyone confirm if this is a bug or correct me if I am wrong, please? |
2019-01-14 11:17:23 -0500 | commented question | E+, defining DOAS fan specifications according to manufacturer's book Here there is a post about the pressure input to the fan models, I hope it helps: https://unmethours.com/question/14589/ |
2019-01-14 11:12:03 -0500 | asked a question | VRF performance curve: EIR boundary temperature VRF performance curve: EIR boundary temperature I tried a simple case of VRF system with EnergyPlus v9.0. I reported the |
2018-11-16 04:13:22 -0500 | marked best answer | HVACTemplate:System:ConstantVolume minimum outdoor air schedule doesn't work This is a question about the HVACTemplate:System:ConstantVolume object in EnergyPlus 9.0. I am defining a schedule in the field "Minimum Outdoor Air Schedule Name" of this template, but the simulation results show that the outdoor air is always entering the zone. I have checked the .expidf file and noticed that the schedule I defined is missing in the corresponding "Controller:OutdoorAir" object. If I fill that "Controller:OutdoorAir" with the schedule, I get the results I expected. Can you please tell me if there is a way to define the outdoor air schedule with this HVAC Template, without editing the expanded file? Thank you! |
2018-11-16 04:13:22 -0500 | received badge | ● Scholar (source) |
2018-11-09 04:34:58 -0500 | edited question | HVACTemplate:System:ConstantVolume minimum outdoor air schedule doesn't work HVACTemplate:System:ConstantVolume minimum outdoor air schedule This is a question about the HVACTemplate:System:Constan |
2018-11-09 04:34:58 -0500 | received badge | ● Editor (source) |
2018-11-08 08:37:50 -0500 | received badge | ● Student (source) |
2018-11-08 07:42:49 -0500 | asked a question | HVACTemplate:System:ConstantVolume minimum outdoor air schedule doesn't work HVACTemplate:System:ConstantVolume minimum outdoor air schedule This is a question about the HVACTemplate:System:Constan |
2018-09-25 07:35:36 -0500 | received badge | ● Teacher (source) |
2018-09-24 09:02:10 -0500 | answered a question | What software can generate an energy model from CAD or BIM? I can add to the Importing list CYPETHERM EPlus, an energy simulation software which is a BIM user interface of EnergyPl |
2017-10-17 06:01:00 -0500 | received badge | ● Supporter (source) |