Richard's profile - activity

2022-06-27 08:52:33 -0500 received badge  Popular Question (source)
2018-01-09 23:32:41 -0500 marked best answer the difference between "Cooling Coil Sensible Cooling Rate"and"Zone Predicted Sensible Load to Cooling Setpoint Heat Transfer Rate"

The module i used is HVAC Template:Zone:FanCoil .

I found there is a little difference between "Cooling Coil Sensible Cooling Rate" and "Zone Predicted Sensible Load to Cooling Setpoint Heat Transfer Rate".

What is the difference between these two?

image description

2018-01-07 20:50:36 -0500 commented answer the difference between "Cooling Coil Sensible Cooling Rate"and"Zone Predicted Sensible Load to Cooling Setpoint Heat Transfer Rate"

So ,the zone predicted sensible load doesn't include outdoor air sensible load right? The fan heat load is quite littl

2018-01-07 20:21:24 -0500 commented answer the difference between "Cooling Coil Sensible Cooling Rate"and"Zone Predicted Sensible Load to Cooling Setpoint Heat Transfer Rate"

So ,the zone predicted sensible load doesn't include outdoor air sensible load right? The fan heat load normally is qui

2018-01-04 21:38:17 -0500 asked a question the difference between "Cooling Coil Sensible Cooling Rate"and"Zone Predicted Sensible Load to Cooling Setpoint Heat Transfer Rate"

the difference between "Cooling Coil Sensible Cooling Rate"and"Zone Predicted Sensible Load to Cooling Setpoint Heat Tra

2017-08-24 01:37:17 -0500 edited question Strange problem about the huge surface temperature jump ?

Strange problem about the huge surface temperature jump ? What is the most possible reason causing a huge outside surfac

2017-08-24 01:36:15 -0500 received badge  Editor (source)
2017-08-24 01:36:15 -0500 edited question Strange problem about the huge surface temperature jump ?

Strange problem about the huge surface temperature jump ? What is the most possible reason causing a huge outside surfac

2017-08-24 01:35:09 -0500 asked a question Strange problem about the huge surface temperature jump ?

Strange problem about the huge surface temperature jump ? What is the most possible reason causing a huge outside surfac

2017-08-22 22:14:19 -0500 received badge  Teacher (source)
2017-08-22 19:06:13 -0500 edited answer the difference between **Fan Coil Total Cooling Rate** and **Cooling Coil Total Cooling Rate**?

Another description for this topic: The Fan Coil Total Cooling Rate is about the condition between R.A. and S.A. The

2017-08-21 19:48:12 -0500 received badge  Supporter (source)
2017-08-21 19:48:06 -0500 marked best answer the difference between **Fan Coil Total Cooling Rate** and **Cooling Coil Total Cooling Rate**?

What is the difference between Fan Coil Total Cooling Rate and Cooling Coil Total Cooling Rate? I put ZoneHVAC:FourPipeFanCoil in a zone,and i found huge difference between Fan Coil Total Cooling Rate and Cooling Coil Total Cooling Rate, the Cooling Coil Total Cooling Rate is much larger than Fan Coil Total Cooling Rate, why?

2017-08-21 19:48:06 -0500 received badge  Scholar (source)
2017-08-21 19:47:43 -0500 answered a question the difference between **Fan Coil Total Cooling Rate** and **Cooling Coil Total Cooling Rate**?

Another description for this topic: The Fan Coil Total Cooling Rate is about the condition between R.A. and S.A. The

2017-08-21 08:38:47 -0500 received badge  Student (source)
2017-08-21 08:29:55 -0500 asked a question the difference between **Fan Coil Total Cooling Rate** and **Cooling Coil Total Cooling Rate**?

the difference between **Fan Coil Total Cooling Rate** and **Cooling Coil Total Cooling Rate**? What is the difference b