2022-10-18 10:09:46 -0500 | edited question | Zone Loads Report OpenStudio Measure error Zone Loads Report OpenStudio Measure error I have a model running in the OpenStudio v2.9.1 and I am working on diagnosin |
2022-10-18 10:09:39 -0500 | commented question | Zone Loads Report OpenStudio Measure error I'm not sure the file upload worked. The error starts with: "Error: undefined method 'isRatedSensibleHeatRatioAutosize |
2022-10-18 10:05:47 -0500 | asked a question | Zone Loads Report OpenStudio Measure error Zone Loads Report OpenStudio Measure error I have a model running in the OpenStudio v2.9.1 and I am working on diagnosin |
2022-10-11 11:15:04 -0500 | received badge | ● Commentator |
2022-10-11 11:15:04 -0500 | commented answer | Zone Component Load Summary Breakdown I'm forced to use OS 2.9. Is there a way to get a version of this measure that will work with that version of OS? The cu |
2022-06-06 14:16:30 -0500 | commented answer | Modeling Slab Insulation in OS Any updates on this? I am running OpenStudio 2.9.1. I can create a new "F-Factor Ground floor construction" and input th |
2022-06-06 13:21:01 -0500 | received badge | ● Critic (source) |
2022-01-28 14:11:45 -0500 | commented question | Window U-factor issues 3) Angular properties are far above my experience level with window modeling. I would hope that if only changed the U-fa |
2022-01-28 14:08:05 -0500 | commented question | Window U-factor issues Thanks for the thoughts on that. Additional info: this is in climate zone 7. 1) For SHGC being the same in both models |
2022-01-27 23:10:41 -0500 | received badge | ● Popular Question (source) |
2022-01-20 10:54:27 -0500 | commented question | Window U-factor issues The model is created in the Sketchup plugin and modified in OpenStudio 2.9 |
2022-01-20 10:53:15 -0500 | asked a question | Window U-factor issues Window U-factor issues I am working to model window improvements in a multifamily building tower. I have confirmed that |
2022-01-20 10:52:28 -0500 | asked a question | Windows efficiency and energy use Windows efficiency and energy use I am working to model window improvements in a multifamily building tower. I have conf |
2021-11-21 10:43:34 -0500 | commented question | PTAC with hot water Baseboards Openstudio Thanks for the reply! The model is here: https://pcdengineering.egnyte.com/dl/fzFwXIV6HU 1) my hope was that for all ho |
2021-11-19 16:48:01 -0500 | edited question | PTAC with hot water Baseboards Openstudio openstudio schedule only run fans in heating mode I have a "Baseboard convective water" system sized to fully meet space |
2021-11-19 16:47:15 -0500 | asked a question | PTAC with hot water Baseboards Openstudio openstudio schedule only run fans in heating mode I have a "Baseboard convective water" system sized to fully meet space |
2021-11-19 16:46:30 -0500 | asked a question | PTAC cooling and hot water baseboard heating OpenStudio PTAC cooling and hot water baseboard heating OpenStudio I have a "Baseboard convective water" system sized to fully meet |
2021-02-23 13:06:14 -0500 | commented question | High airlfow and fan sizing eQuest, Build 7175 Looks like it might be an issue with the PSZ system type. When I switch to heat pump (residential) with PVVT sizing goes |
2021-02-19 20:47:17 -0500 | asked a question | High airlfow and fan sizing eQuest, Build 7175 High airlfow and fan sizing eQuest, Build 7175 Greetings Modelers, I'm working on a model for Appendix G (LEED) baseline |
2021-02-19 20:47:13 -0500 | asked a question | High airlfow and fan sizing eQuest, Build 7175 High airlfow and fan sizing eQuest, Build 7175 Greetings Modelers, I'm working on a model for Appendix G (LEED) baseline |
2019-09-10 00:51:49 -0500 | received badge | ● Popular Question (source) |
2019-09-03 11:06:44 -0500 | marked best answer | PTHP system in eQuest Build 7175 eQuest Users, I started a simple box model in Build 7175 with DoE 2.3 selected and switched the HVAC system to PTHP (all in wizard mode) and got "Illegal Codeword" errors for each system and "terminal type=undefined" for each thermal zone. All errors go away when I switch back to PSZ heat pump. Anyone have thoughts on this? |
2019-09-02 20:23:11 -0500 | commented answer | PTHP system in eQuest Build 7175 Thanks for the tip. I agree that PSZ would work fine, just noting that there are systems still in the wizard that will n |
2019-08-22 15:42:40 -0500 | asked a question | PTHP system in eQuest Build 7175 PTHP system in eQuest Build 7175 eQuest Users, I started a simple box model in Build 7175 with DoE 2.3 selected and sw |
2017-09-08 15:20:26 -0500 | edited question | Condenser Air evaporative pre-cooling Condenser Air evaporative pre-cooling I am working to model (in OpenStudio/E+) a condenser air evaporative pre-cooling u |
2017-09-08 15:16:44 -0500 | asked a question | Condenser Air evaporative pre-cooling Condenser Air evaporative pre-cooling I am working to model (in OpenStudio/E+) a condenser air evaporative pre-cooling u |
2017-09-08 15:11:09 -0500 | commented answer | OpenStudio 2.1.1 Results Tab Unavailable Hmmm I have a Toshiba Satellite with Intel HD graphics only so I cant change that setting. It does work when I open it t |
2017-09-06 19:44:10 -0500 | received badge | ● Teacher (source) |
2017-09-06 16:41:17 -0500 | answered a question | Utility Demand Charge Output Found it under "Tariff Report". Sorry! |
2017-09-06 16:28:14 -0500 | asked a question | Utility Demand Charge Output Utility Demand Charge Output I'm running OS 2.2.0 and am looking for a report that shows the breakdown of dollars due t |
2017-09-06 16:05:24 -0500 | commented answer | OpenStudio 2.1.1 Results Tab Unavailable Same problem here. Results tab only works when I open the model through the SketchUp plugin. I'm running OS 2.2.0 |
2017-09-06 16:03:33 -0500 | received badge | ● Supporter (source) |
2017-09-06 16:03:24 -0500 | commented answer | OpenStudio 2.1.1 Results Tab Unavailable Same problem here. Results tab only works when I open the model through the SketchUp plugin |
2017-08-15 09:45:22 -0500 | marked best answer | SketchUp vs OS gui workflow After a brief search I didn't see a discussion on this. So I was wondering where people usually make the switch from the SketchUp plugin to the OS interface. I'm guessing somewhere after geometry and thermal zones and before HVAC, loads and schedules. Also, do people have a mental bullet point list of items to take care of in SketchUp that will make life hard later on in the modeling if missed? Thanks! Jacob |
2017-08-15 09:45:22 -0500 | received badge | ● Scholar (source) |
2017-08-14 12:54:19 -0500 | received badge | ● Student (source) |
2017-08-14 12:53:39 -0500 | asked a question | SketchUp vs OS gui workflow SketchUp vs OS gui workflow After a brief search I didn't see a discussion on this. So I was wondering where people usua |