2017-09-07 06:00:01 -0500 answered a question Hi, What are the ways to have an interactive 3D viewer of building geometry(json or gbXML file) in web browser ?

@sde - didn't you already ask this question: https://unmethours.com/question/26300/3d-geometry-view-of-gbxml-files/

2017-09-05 06:07:18 -0500 commented question Zone Ventilation

Please tag your question with the software you are using.

2017-09-05 06:07:18 -0500 received badge  Commentator
2017-09-02 07:02:01 -0500 received badge  Critic (source)
2017-09-02 07:01:56 -0500 answered a question room tempreature

In EnergyPlus you need to define a thermostat object and reference that thermostat for your equipment. In OpenStudio you

2017-09-01 18:05:40 -0500 answered a question How to fully retract the blinds when slat control = BlockBeamSolar and no solar beam is reaching the window?

I think there a few options for shade control to accomplish what youre trying (example: http://bigladdersoftware.com/epx

2017-08-31 10:45:57 -0500 commented question Cooling Load for Interzone Wall negative?

Zone temperature setpoint != zone temperature; you could check zone temperatures to confirm all adjacent zones are same

2017-08-31 10:43:54 -0500 commented question Cooling Load for Interzone Wall negative?

Zone temperature setpoint != zone temperature; you could check zone temperatures to confirm all adjacent zones are same

2017-08-28 21:40:59 -0500 commented answer Warmest vs WarmestTemperatureFlow SetpointManager

Very nice points.

2017-08-28 21:39:50 -0500 answered a question Warmest vs WarmestTemperatureFlow SetpointManager

I think you are going to get different answers here from different people, but you seem to be asking a plant/system opti

2017-08-28 21:29:02 -0500 commented question Cooling Load for Interzone Wall negative?

Is this the zone level cooling peak? What date/time of day does it occur and what is the geography? Do all peaks for all

2017-08-19 07:02:45 -0500 commented answer ice storage in openstudio does not change results

I think you want one chiller and one tank, in parallel. Also - what are the units of tank capacity? Maybe its too small?

2017-08-19 06:59:45 -0500 commented answer ice storage in openstudio does not change results

I think you want one chiller and one tank, in parallel.

2017-08-19 06:58:39 -0500 commented question Unexplained start date sensitivity in E+ Simulation

When I started reading, I was going to suggest warmup days, but you have certainly looked at that aspect. Are you doing

2017-08-19 06:02:45 -0500 answered a question Does the supply air flow rate include the amount of air come in the room through natural/mechanical ventilation

Your supply/design air flowrate should account for ventilation loads; I recommend refering to the Engineering Reference

2017-08-19 05:47:07 -0500 commented question Unexplained start date sensitivity in E+ Simulation

When I started reading, I was going to suggest warmup days, but you gave certainly looked at that aspect. Are you doing

2017-08-18 12:59:06 -0500 commented answer energy plus electric usage breakdown

Glad it worked - I think the protocol when you get the solution is to select an answer and append the question with '[cl

2017-08-18 07:19:13 -0500 answered a question energy plus electric usage breakdown

How much is the error? There may be meters that are not setup (meaning they need to be defined) in order to capture all

2017-08-16 13:05:22 -0500 commented answer ice storage in openstudio does not change results

Aha - most examples I see have the ice storage in parallel; you have it in series here. Unless control is setup properly

2017-08-16 13:04:04 -0500 commented answer ice storage in openstudio does not change results

Aha - most examples I see have the ice storage in parallel; you have it in series here.

2017-08-16 07:35:59 -0500 answered a question ice storage in openstudio does not change results

I don't have much experience with ice storage in OS, but there are quite a few posts on this site for ice storage in bot

2017-08-14 16:02:11 -0500 commented answer Issues Creating Measures - Plug Load Density Example

Thanks; not sure why I didn't think of modifying the reduce loads by percentage measure!

2017-08-14 14:32:41 -0500 marked best answer Issues Creating Measures - Plug Load Density Example

Hey everyone - first post; read a lot of posts over the years, thanks to everyone who contributes. I'm getting started a little late with OpenStudio and hoping someone can help me iron out some issues I'm having with measure creation using a simple example. I do not have much experience with Ruby or Python, apologies in advance.

I'm looking to create a measure that modifies the Electric Equipment object to set a W/m^2 density. I started with the "Set Lighting Loads by LPD" from the BCL, and did a quick copy/paste of the directory and renamed as "Set Plug Loads by Density". I've tried a couple of modifications (i.e., removing reference to luminaire objects which aren't applicable to plug loads) without success. My thought is that all I should need to do is replace the "LightsDefinition" reference to "ElectricEquipmentDefinition", but I get a failure during 'Processing OpenStudio Measures".

Can anyone shed light on this measure/clarify if I'm not understanding the OS objects correctly?

I'm also seeing two indicators in the Measures screen that I'm hoping someone can also clarify (I don't see in documentation on this site or OS documentation): a red triangle with exclamation point when a measure is dragged into the project, and what looks like a piece of paper broken in the measures library (I assume this means the file is not formatted correctly/missing components).

2017-08-14 14:32:41 -0500 received badge  Scholar (source)
2017-08-14 06:51:01 -0500 received badge  Teacher (source)
2017-08-13 23:34:42 -0500 received badge  Student (source)
2017-08-13 23:28:57 -0500 answered a question Make all units consistent across EnergyPlus reports

If I'm understanding your question correctly, you may be looking for the OutputControl:Table:Style object. There is one

2017-08-13 23:28:57 -0500 commented answer OpenStudio: Editing and Removing HVAC

As a follow-up to this question, has anyone come up with a way of removing HVAC that is not attached to a thermal zone (

2017-08-13 23:28:57 -0500 asked a question Issues Creating Measures - Plug Load Density Example

Issues Creating Measures - Plug Load Density Example Hey everyone - first post; read a lot of posts over the years, than

2017-08-12 17:04:28 -0500 received badge  Supporter (source)