Fan's profile - overview
overview
network
karma
followed questions
activity
81
karma
follow
Registered User
real name
Fan Feng
member since
7 years ago
last seen
2 years ago
location
College station,
todays unused votes
30
votes left
Ph.d. Student in Texas A&M
10
Questions
185
views
1
answer
3
votes
7 years ago
Molly Curtz
Why is the result of plantloop operation incompatible with the strategy specified in EMS:Program?
energyplus
ems
plant-loop
333
views
1
answer
1
vote
6 years ago
rraustad
I want to control the Air mass flow rate of VAV box. Is this viable in EnergyPlus?
vav
flow-control
energyplus
321
views
no
answers
1
vote
7 years ago
Fan
trend value of previous system timestep not the zone timestep
ems
104
views
no
answers
1
vote
6 years ago
Fan
How can I set a custom day in Schedule:compact? [closed]
schedule
energyplus
46
views
no
answers
no
votes
4 years ago
Fan
high outside face temperature in winter. [closed]
energyplus
load-calculation
1
view
no
answers
no
votes
4 years ago
Fan
how to set the -dim values(sample area) for genBSDF? [deleted]
genbsdf
7
views
no
answers
no
votes
4 years ago
Fan
high outside face temperature in winter. [deleted]
energyplus
load-calculation
1
view
no
answers
no
votes
4 years ago
Fan
how to set the -dim values(sample area) for genBSDF? [deleted]
genbsdf
109
views
1
answer
no
votes
4 years ago
Fan
how to set the -dim values(sample area) for genBSDF?
bsdf
77
views
no
answers
no
votes
5 years ago
Fan
how can I export the velocity distribution in a certain surface from the CFD result in DesignBuilder?
cfd
designbuilder
3
Answers
2
Find Root Simple Controller: Controller Water Coil Error
0
how to set the -dim values(sample area) for genBSDF?
0
To model PCM hysteresis in EnergyPlus, what are the high/low temp difference of freezing/melting curves?
10
Votes
10
0
21
Tags
energyplus
× 14
ems
× 6
bsdf
× 4
vav
× 3
plant-loop
× 3
phase-change-material
× 3
flow-control
× 3
radiance
× 2
daylighting
× 2
load-calculation
× 2
genbsdf
× 2
cooling-coil
× 1
python
× 1
schedule
× 1
designbuilder
× 1
error
× 1
heating-coil
× 1
condenser-loop
× 1
cfd
× 1
python-plugin
× 1
python-ems
× 1
7
Badges
●
Editor
×
1
Why is the result of plantloop operation incompatible with the strategy specified in EMS:Program?
●
Teacher
×
1
Find Root Simple Controller: Controller Water Coil Error
●
Rapid Responder
×
1
how to set the -dim values(sample area) for genBSDF?
●
Supporter
×
1
Are there two different Timesteps in EnergyPlus?
●
Student
×
1
Why is the result of plantloop operation incompatible with the strategy specified in EMS:Program?
●
Enthusiast
×
1
●
Commentator
×
1
How can I use Pandas in a derived class of EnergyPlusPlugin
Site design and logo: Copyright © 2015 Big Ladder Software LLC. All rights reserved.
The
Unmet Hours
and
Big Ladder
names and logos are trademarks of Big Ladder Software LLC.
User contributions licensed under the
Creative Commons Attribution Share Alike 3.0 License
.
Powered by
Please note: Unmet Hours requires javascript to work properly, please enable javascript in your browser,
here is how