2021-02-08 02:27:24 -0500 received badge  Popular Question (source)
2018-08-22 13:11:48 -0500 received badge  Self-Learner (source)
2017-06-01 10:01:45 -0500 commented answer VAV system but costant air flow rate

Yes, you are right, the Rooftop unit can be a bit oversized, but the airflow rate (mixed air) is constant on a value gre

2017-06-01 10:00:27 -0500 commented answer VAV system but costant air flow rate

Hi, i set min and max air flow rate in Fan:Variable. Also the controller is correct, where i defined the outside air flo

2017-06-01 10:00:02 -0500 commented answer VAV system but costant air flow rate

Yes, you are right, the Rooftop unit can be a bit oversized, but the airflow rate is constant on value greater the min (

2017-06-01 09:58:57 -0500 commented answer VAV system but costant air flow rate

Hi, i set min and max air flow rate in Fan:Variable. Also the controller is correct, where i defined the outside air flo

2017-06-01 09:58:57 -0500 commented answer VAV system but costant air flow rate

Yes, you are right, the Rooftop unit can be a bit oversized, but the airflow rate is costant on value greater the min (O

2017-06-01 09:46:27 -0500 marked best answer VAV system but costant air flow rate

Hi, i can't understand why the rooftop with variable volume fans is always constat with the outdoor air and the design airflow rate i defined in E+. I suppose the first one should be remain constant, while the second should change depending on the cooling/heating load. Where am i getting wrong with the model?Thank you.

2017-05-23 11:05:40 -0500 asked a question VAV system but costant air flow rate

VAV system but costant air flow rate Hi, i can't understand why the rooftop with variable volume fans is always constat

2017-05-12 05:25:26 -0500 marked best answer From space to thermal zone

I'm asking if there is a function to automatically generate a thermal zone associated to each space, using the same name of the space for example. This would easily shorten the work time. Thank you.

2017-05-11 10:17:49 -0500 asked a question From space to thermal zone

From space to thermal zone I'm asking if there is a function to automatically generate a thermal zone associated to each

2017-05-08 10:28:53 -0500 commented answer Openstudio crashes when running simulation and when going on measure tab

Thank you, now the simulation finally started. How does it happen these kind of problems?There is a way to avoid them?

2017-05-06 11:24:41 -0500 marked best answer Openstudio crashes when running simulation and when going on measure tab

I use openstudio 2.1, but i tried also with v1.11. When i start the simulation it gives me this messages: -Initializing workflow. -Processing OpenStudio Measures. -Translating the OpenStudio Model to EnergyPlus.

Then it crashes: with 2.1 stopping at 100% without creating an idf; in 1.11 closing automatically the software. Anyone wo can help me?i already removed every geometry error, verified construction sets. Is it a software, compatatibility error?i use Sketchup2016Pro. OS crashes also if i click on measure tab.

2017-05-05 03:20:16 -0500 received badge  Supporter (source)
2017-05-05 03:19:30 -0500 commented question Openstudio crashes when running simulation and when going on measure tab

Do you have good news? I really appreciate the hard work you do.

2017-05-03 03:20:23 -0500 edited question Openstudio crashes when running simulation and when going on measure tab

Openstudio crashes when running simulation and when going on measure tab I use openstudio 2.1, but i tried also with v1.

2017-05-03 03:19:00 -0500 edited question Openstudio crashes when running simulation and when going on measure tab

Openstudio crashes when running simulation I use openstudio 2.1, but i tried also with v1.11. When i start the simulatio

2017-05-02 08:39:29 -0500 asked a question Openstudio crashes when running simulation and when going on measure tab

Openstudio crashes when running simulation I use openstudio 2.1, but i tried also with v1.11. When i start the simulatio

2017-04-28 11:33:45 -0500 received badge  Teacher (source)
2017-04-28 11:02:31 -0500 answered a question Energy consumption for heating too low

The problem was in the natural ventilation: the value assumed (0.3 airchanges/hour costantly as infiltration) was too lo

2017-04-26 09:55:31 -0500 commented question Energy consumption for heating too low

I found out something interesting that may help resolving my issue: 1_Cooling coil total cooling energy of the coil:wa

2017-04-18 12:11:45 -0500 commented question Energy consumption for heating too low

Total building area is 810 m2 (8700 ft2); winter thermostat settings are 20°C (68°F), summer is 26°C (78.8°C), both considering 8 hour/day schedule. Heating system is composed by: waterheater:heatpump:pumpedcondenser with Coil:WaterHeating:AirToWaterHeatPump:Pumped which is 55,7kW-COP 3.3; i don't have any heat recovery.

2017-04-18 10:14:11 -0500 received badge  Editor (source)
2017-04-18 10:11:49 -0500 asked a question Energy consumption for heating too low

I modeled a office building in Rome-Italy, ashrae climate zone 4A. Window-wall ratio is 22% with a good performance envelope in terms of tramittance. HVAC is composed of a reversible Heatpump/chiller air-to-water (COP and EER around 3.0) and fancoils, with natural ventilation, which i assumed about 0.3 airchanges/hour. Annual consumption for cooling is 28000 kWH, while heating, accounted in water system - other (i used waterheater:mixed+waterheater:heatpump) is 1500 kWh. UnmetSetpoint hours are below 50 hours. Moreover in the PEAK ENERGY END-USE - ELECTRICITY table, values for heating and cooling are similar: with maximum respectively of 25.3 kW (which and 22.2 kW C:\fakepath\Cattura.JPG C:\fakepath\Cattura2.JPG The second screenshot is from resultviewer and shows how the heatpump coil and the chiller power are not so different.

2017-04-05 10:22:06 -0500 received badge  Scholar (source)
2017-04-05 10:22:03 -0500 commented answer Construction Name is required but was blank

OK, now seems it works!Really thank you!Just one thing, even if the simulation doesn't show problems, in the sketchup plug-in surfaces still doesn't have a connection with the construction name. Anyway it's ok

2017-04-04 08:44:39 -0500 commented question Construction Name is required but was blank

It's for all the surfaces. I used adiabatic boundary just for a few surfaces which have same problem.

2017-04-04 08:40:15 -0500 received badge  Student (source)
2017-04-04 08:17:46 -0500 asked a question Construction Name is required but was blank

The problem it's that even following other people's advice i still have all my building surfaces without a construction name. I had created a construction set with all the types of constructions in Open Studio. Then i selected the whole model also in SketchUp Plug-in to set my "construction set" using the "Set Attributes Tool". I tried also to use the measure "Remove Orphan Subsurfaces plugin" , but nothing. I cheked also if the model has glass doors, but it's not that problem. So the funny thing it's that only fixed windows has the correct construction name. Other surfaces have everything in theyr places (name, surface type, outside boundary condition) except construction name. How can I fix this problem?