2021-06-16 10:31:15 -0500 commented answer Boiler Hourly Loads Energy Plus

Thanks so much Cody, I will dig into this a little more with your suggestions and see what I can get figured out. I real

2021-06-14 13:04:10 -0500 commented question Boiler Hourly Loads Energy Plus

Below is a link to my model if anyone has time to a look. https://drive.google.com/file/d/1CCgIwD5IzqyURJODQ0kPedl_Y1w

2021-06-14 13:00:59 -0500 commented question Boiler Hourly Loads Energy Plus

Thanks Cody, the supply and return temps to the boiler look good. After further investigation however, I think something

2021-06-11 09:13:55 -0500 asked a question Boiler Hourly Loads Energy Plus

Boiler Hourly Loads Energy Plus Hi all, working on a boiler with radiant floor heat model. I have the system set to auto

2021-06-11 09:11:03 -0500 marked best answer Open Loop Ground Source Heat Pump in E+

I am working on modeling an open loop geothermal heat pump in E+ and am having issues with my water temperature. I have read one post about how to model an open loop system by using PlantComponent:TemeratureSource which is what I used for model. I specify a PlantComponent:TemperatureSource with a constant temperature of 47 F (local deep ground water temperature). I have coupled this with setpointmanager:scheduled (which is a schedule of 47 F for all days) and PlantEquipmentOperation:Uncontrolled. When I run my model and look at the CondenserLoopDemandReport:Monthly, the report is indicating a loop supply temperature of -37 C (~ -35 F) which is WAY too low. Any thoughts on why this is happening and how I might be able to fix it?

2021-06-11 09:11:03 -0500 received badge  Scholar (source)
2021-06-11 09:10:58 -0500 received badge  Supporter (source)
2021-06-11 09:09:34 -0500 asked a question Boiler Hourly Loads Energy Plus

Boiler Hourly Loads Energy Plus Hi all, working on a boiler with radiant floor heat model. I have the system set to auto

2021-05-14 10:42:18 -0500 commented question Open Loop Ground Source Heat Pump in E+

attached is a link to my IDF file. https://drive.google.com/file/d/1vpgl8_t-QQr7gJPAVrxLY9G_OaHrGIhd/view?usp=sharing

2021-05-13 13:31:42 -0500 asked a question Open Loop Ground Source Heat Pump in E+

Open Loop Ground Source Heat Pump in E+ I am working on modeling an open loop geothermal heat pump in E+ and am having i

2021-05-13 13:26:47 -0500 commented answer How to model a GSHP coupled with ground water open loop in E+ and/or Design Builder??

I am working on a similar system and am having issues with my water temperature. I specify a PlantComponent:TemperatureS

2021-05-13 13:26:33 -0500 commented question How to model a GSHP coupled with ground water open loop in E+ and/or Design Builder??

I am working on a similar system and am having issues with my water temperature. I specify a PlantComponent:TemperatureS

2021-04-29 10:18:13 -0500 received badge  Editor (source)
2021-04-29 10:18:13 -0500 edited question Combination Geothermal and Solar Thermal Heating System

Combination Geothermal and Solar Thermal Heating System Hello Unmet Hours Community, I am brand new to Energy Plus and

2021-04-29 10:16:36 -0500 asked a question Combination Geothermal and Solar Thermal Heating System

Combination Geothermal and Solar Thermal Heating System Hello Unmet Hours Community, I am brand new to Energy Plus and

2021-04-27 14:42:28 -0500 asked a question Splitter/Mixer not matched error

Splitter/Mixer not matched error I am trying to model a geothermal heat pump in Energy Plus. I am pretty much brand new

2021-04-27 12:12:39 -0500 received badge  Student (source)
2021-04-24 15:24:36 -0500 asked a question Model parallel pumps to operate staged Heat Pumps

Model parallel pumps to operate staged Heat Pumps Hi, I am trying to use E+ to model two heat pumps which have staged op