First time here? Check out the Help page!
2023-06-15 09:51:33 -0500 | commented question | ChangeBuildingLocation BCL measure and PAT compatible? how about the setting for climate zone calendar year, upstream argument values, and find and replace option etc.? How to |
2023-06-14 20:34:23 -0500 | commented answer | Using more than one weather file in PAT seems like when the measure is running, it is trying to file the weather file name whatever we put in the PAT and match |
2023-06-14 20:08:50 -0500 | commented question | OpenStudio Failed To Set Weather File there might be some file name issue (eg file name starting with ".") in the default weather file library when first dow |
2023-06-14 18:55:21 -0500 | commented answer | Run Prototype DoE buildings with custom weather Hi David for the changing building location measure in PAT, the only input is the weather file name not location /file a |
2022-11-07 14:18:26 -0500 | commented question | how to add VAV box to VRF with DOAS system Hi Neil thank you for the comments, this is really helpful |
2022-11-07 14:11:42 -0500 | asked a question | how to check the box for autodemand shed control, ECMS under DDC system in cbecc-com2016 how to check the box for autodemand shed control, ECMS under DDC system in cbecc-com2016 Hi I got one cbecc-com 2016 mo |
2022-11-07 13:52:18 -0500 | asked a question | how to check cbecc-com DCV form under zonal AHU how to check cbecc-com DCV form under zonal AHU Hi I got one cbecc-com2016 model which has lots of zonal heat pumps. And |
2022-11-07 13:47:06 -0500 | asked a question | where to check the zonal DCV system form at cbecc com where to check the zonal DCV system form at cbecc com Hi I have one cbecc-com model 2016 and each thermal zone has smal |
2021-05-31 22:01:07 -0500 | commented answer | Radiant floor slab If it is just electric radiant panel, can I just add a electric coil to the zone for this loop? Thank you |
2021-05-27 22:47:55 -0500 | commented question | What are your techniques for reducing unmet hours? Do those 300 hours refer to occupied hours or total, ? |
2021-05-27 17:40:20 -0500 | commented question | how to add VAV box to VRF with DOAS system especially for ventilation and heating load for each system capacity Thank you |
2021-05-27 11:43:22 -0500 | commented question | packaged rooftop unit to doas ventilation calculation is different than manually calculation by the spreadsheet calculation per IMC how they are calculated for ventilation when it comes to ducted/combine system. why is it different from traditional ca |
2021-05-27 11:43:06 -0500 | commented question | packaged rooftop unit to doas ventilation calculation is different than manually calculation by the spreadsheet calculation per IMC how they are calculated for ventilation when it comes to ducted/combine system. why it is different from traditional cal |
2021-05-27 11:42:55 -0500 | commented question | packaged rooftop unit to doas ventilation calculation is different than manually calculation by the spreadsheet calculation per IMC how they are calculate for ventilation when it comes to ducted/combine system. why it is different from traditional calc |
2021-05-27 11:41:01 -0500 | commented question | packaged rooftop unit to doas ventilation calculation is different than manually calculation by the spreadsheet calculation per IMC the same system , and the vrf auto sizing has 0 cooling capacity ; but the heating is fine |
2021-05-27 11:39:37 -0500 | edited question | packaged rooftop unit to doas ventilation calculation is different than manually calculation by the spreadsheet calculation per IMC packaged rooftop unit to doas ventilation calculation is different from spreadsheet I am using openstudio to model doas |
2021-05-27 11:39:16 -0500 | edited question | packaged rooftop unit to doas ventilation calculation is different than manually calculation by the spreadsheet calculation per IMC packaged rooftop unit to doas ventilation calculation is different than manually calculation by the spreadsheet I am usi |
2021-05-27 11:38:34 -0500 | asked a question | packaged rooftop unit to doas ventilation calculation is different than manually calculation by the spreadsheet calculation per IMC packaged rooftop unit to doas ventilation calculation is different than manually calculation by the spreadsheet I am usi |
2021-05-27 10:38:10 -0500 | commented question | Error with "ZEDG VRF with DOAS" measure thank you David so we will prefer ZEDG one when pick up VRF |
2021-05-26 23:30:55 -0500 | asked a question | Errors found in VRF system input Errors found in VRF system input Hi I was trying to run a simple model but got the error like below If you need additio |
2021-05-26 22:34:59 -0500 | commented answer | Split type Inverted heat pump model with multiple indoor units I add VRF, terminal unit and zone attached to each terminal but where to add coil ?thank you |
2021-05-26 18:12:03 -0500 | commented answer | Issue with VRF with DOAS Measure Hi David why this measure the outdoor heating and cooling flow rate are default as hard size ?Thank you |
2021-05-26 17:57:06 -0500 | asked a question | how to add VAV box to VRF with DOAS system how to add VAV box to VRF with DOAS system Hi I am using openstudio for energy modeling and run a measure called VRF wit |
2021-05-26 10:46:04 -0500 | commented question | Error with "ZEDG VRF with DOAS" measure Hi David May I ask you what is the difference between the VRF with DOAS and ZEDG VRF with DOAS measures Thank you |
2021-05-10 21:44:13 -0500 | commented answer | Multizone Packaged Rooftop Heat Pump for ASHRAE Baseline why the baseline system can't be a combination of two system, and some baseline system don't have outside air ? Thank yo |
2021-05-07 23:15:37 -0500 | asked a question | Error: Version extracted from file '3.2.0' is newer than current OpenStudio Version 3.1.0. Error: Version extracted from file '3.2.0' is newer than current OpenStudio Version 3.1.0. When I try to open a osm mode |
2021-04-25 22:06:57 -0500 | edited question | after changing thermal zone in sketchup, the thermal zone list in OS still remains the same after changing thermal zone in sketchup, the thermal zone list in OS still remains the same Hello, I changed the therma |
2021-04-25 22:03:30 -0500 | edited question | after changing thermal zone in sketchup, the thermal zone list in OS still remains the same after changing thermal zone in sketchup, the thermal zone list in OS still remain the same Hello, I changed the thermal |
2021-04-25 22:03:03 -0500 | edited question | after changing thermal zone in sketchup, the thermal zone list in OS still remains the same change thermal zone in sketchup while the thermal zone in OS still remain the same Hello, I changed the thermal zone in |
2021-04-25 22:02:18 -0500 | asked a question | after changing thermal zone in sketchup, the thermal zone list in OS still remains the same change thermal zone in sketchup while the thermal zone in OS still remain the same Hello, I changed the thermal zone in |
2021-04-21 09:52:47 -0500 | commented answer | how to group space by thermal zone I am using openstudio thank you David, |
2021-04-19 21:20:59 -0500 | commented question | after changing the ceiling height the model got broken thank you Jono, when I selected the edges and moved them, there are some points didn't get moved together for some reaso |
2021-04-19 21:17:42 -0500 | commented question | can't split one space thank you Jono, I will definitely try floorspace |
2021-04-19 21:14:50 -0500 | asked a question | how to group space by thermal zone how to group space by thermal zone Hi I am trying to group different space into thermal zone for modeling, While the mec |
2021-04-19 21:14:48 -0500 | asked a question | how to group space by thermal zone how to group space by thermal zone Hi I am trying to group different space into thermal zone for modeling, While the mec |
2021-04-14 20:13:19 -0500 | commented answer | Plenums and ceiling heights if we have the warning and the exposed geometry for the model won't reflect the change, while other internal loads are a |
2021-04-14 20:12:10 -0500 | commented answer | Plenums and ceiling heights if we have the warning and the exposed geometry for the model won't reflect the change, while other internal loads are a |
2021-04-14 20:11:50 -0500 | commented answer | Plenums and ceiling heights if we have the warning and the exposed geometry for the model won't reflect the change, while other internal loads are a |
2021-04-14 19:17:21 -0500 | commented answer | Splitting existing spaces? thank you for this detailed reply David ! |
2021-04-13 15:58:43 -0500 | asked a question | can't split one space can't split one space Hi I am trying to splitting one space following this video but instead of getting two different s |
2021-04-13 15:55:43 -0500 | commented answer | Splitting existing spaces? Hi David I followed the video drawing another surface inside one space, but it didn't split my space. When I click the s |
2021-04-13 13:21:49 -0500 | commented question | after changing the ceiling height the model got broken Hi David thank you for this timely reply ! I was actually trying to move all the roof, but the inner spaces got problem |
2021-04-13 08:28:39 -0500 | asked a question | after changing the ceiling height the model got broken after changing the ceiling height the model got broken Hi I was trying to changing the ceiling height by moving all th |
2021-04-11 13:42:43 -0500 | commented answer | can't draw a window as a subsurface or set the WWR on a surface thank you so in most cases, the shape and location inside one surface could be flexible |
2021-04-09 15:52:09 -0500 | commented answer | can't draw a window as a subsurface or set the WWR on a surface thank you for this detailed reply. yup when I leave enough space to the edge it is successful. May I ask an extra questi |
2021-04-09 15:49:38 -0500 | received badge | ● Commentator |
2021-04-09 15:49:38 -0500 | commented answer | can't draw a window as a subsurface or set the WWR on a surface thank you for this detailed reply. yup when I leave enough space to the edge it is successful. May I ask an extra questi |
2021-04-08 14:23:24 -0500 | edited question | can't draw a window as a subsurface or set the WWR on a surface can't draw a window as a subsurface or set the WWR on a surface Hello I was trying to manually draw a large window on a |
2021-04-08 14:15:25 -0500 | edited question | can't draw a window as a subsurface or set the WWR on a surface can't draw a window as a subsurface or set the WWR on a surface Hello I was trying to manually draw a large window on a |
2021-04-08 14:14:58 -0500 | edited question | can't draw a window as a subsurface or set the WWR on a surface can't draw a window as a subsurface or set the WWR on a surface Hello I was trying to manually draw a large window on a |