First time here? Check out the Help page!
2023-09-22 13:35:00 -0500 | asked a question | BEopt Error - Option Editor constraint BEopt Error - Option Editor constraint Received this notification today when updating a "pool pump" option that I use to |
2023-09-06 11:15:03 -0500 | asked a question | Unknown Error - BEopt Unknown Error - BEopt i received the following message twice when stopping a simulation immediately after clicking Run s |
2023-08-18 09:51:39 -0500 | commented answer | Possible to Automate BeOpt with Modelkit/Params? @itsjohnhanson, do you have goals to automate model calibration? or data entry or import? or assigning space layouts? or |
2023-08-18 09:51:20 -0500 | commented answer | Possible to Automate BeOpt with Modelkit/Params? @itsjohnhanson, do you have goals to automate model calibration? or data entry or import? or assigning space layouts? or |
2023-07-27 15:42:50 -0500 | commented answer | OpenStudio to BEopt Is this a methodology that would allow the OSM to be generated and calibrated to be compliant with BPI-2400? |
2023-07-25 10:35:38 -0500 | commented answer | OpenStudio to BEopt @shorowit Is there documentation on the method to export/import BEopt into OpenStudio? Is there a recommended workflow f |
2023-05-22 14:14:18 -0500 | commented question | How to incorporate PV w/ Battery Storage in BEopt 2.8 Have you found any documentation that explains the sequence of operation of the battery storage for these considerations |
2023-05-22 14:06:19 -0500 | commented answer | New version of BEopt @shorowit Do we have any approximation for the full v3.0 BEOpt release? |
2023-05-11 16:06:35 -0500 | commented question | Project Run fails (Not Responding) and file disappears I just repeated the problem. I rebuilt the model from scratch, tried rerunning, and received the same "Not Responding" i |
2023-05-11 15:35:45 -0500 | commented question | Project Run fails (Not Responding) and file disappears @shorowit Is anyone else reporting something similar to this experience? I have had two more detailed energy models get |
2023-05-03 16:51:10 -0500 | marked best answer | BEOpt MF errors vented-attic Energy Model recently failed due to errors with attic-vented requiring a floor space. Model here. |
2023-04-18 17:02:53 -0500 | edited question | BEOpt MF errors vented-attic BEOpt MF errors vented-attic Energy Model recently failed due to errors with attic-vented requiring a floor space. Model |
2023-04-18 16:59:50 -0500 | commented question | BEopt v3 MF modelling? @jpierce The point of reference for what is the same temperature was my concern. It seems that the method of "adiabatic" |
2023-04-10 13:41:50 -0500 | commented question | BEopt v3 MF modelling? @shorowit It seems that the difference in the models is to treat all spaces as adiabatic for the adjacent duplex, except |
2023-04-10 13:23:35 -0500 | asked a question | BEOpt MF errors vented-attic BEOpt MF errors vented-attic Energy Model recently failed due to errors with attic-vented requiring a floor space. [Mod |
2023-04-10 13:19:32 -0500 | commented question | BEopt v3 MF modelling? I am curious to understand the appropriate way to utilize the new MF functions for analysis. How should I separate a dup |
2023-02-20 15:54:13 -0500 | commented question | BEopt v3 MF modelling? I am curious to understand the appropriate way to utilize the new MF functions for analysis. How should I separate a dup |
2023-02-20 15:45:00 -0500 | commented question | BEopt v3 MF modelling? I am curious to understand the appropriate way to utilize the new MF functions for analysis. How should I separate a dup |
2023-02-09 10:48:33 -0500 | asked a question | GUI Functions and "Help" GUI Functions and "Help" Can we modify the GUI slightly for BEOpt v3 to include a few features from v2.8? I imagine that |
2023-01-27 11:04:31 -0500 | marked best answer | Failed sizing and HVAC measures Running a basic, vanilla model before entering optimization options. Won't complete due to following error codes. Used v2.8 previously. Ran v3.0 models successfully. This is first new model to fail. Only using default HVAC options currently until I rebuild all my custom measures from v2.8. |
2023-01-27 08:58:00 -0500 | commented question | Failed Model-Converted Living Space Boundaries Were you also not able to reproduce the error when converting attic space to finished ceiling? |
2023-01-24 15:51:50 -0500 | asked a question | Failed Model-Converted Living Space Boundaries Failed Model-Converted Living Space Boundaries I received the following message when building a model. I dragged a Finis |
2023-01-24 09:47:22 -0500 | marked best answer | Severe error for ASHP with switchover control with OAT Received the following error message. See energy model here. |
2023-01-24 09:46:25 -0500 | commented question | Cannot change age of GSHP Correct, I cannot enter/type "1" for the age of equipment. I receive the error message. I am not sure whether the error |
2023-01-23 10:12:45 -0500 | commented answer | New version of BEopt Does BEOpt v3 have testing on Windows 11? Can we confirm if it works there? Has OpenStudio been similarly tested? |
2023-01-23 08:55:05 -0500 | commented question | Cannot change age of GSHP The image for the GSHP shows the default age. I did not select the 10 year age for the equipment. Instead, I'm trying to |
2023-01-20 10:07:48 -0500 | marked best answer | Sizing Run Error BEOpt v3 Running a basic model before entering optimization options in BEOpt v3 with 3.0.0.4 update. Using default options and no custom measures. Receiving the following error code |
2023-01-20 10:06:41 -0500 | marked best answer | Vaulted Ceiling - Envelope - Error Received the following error code. It occurred after adjusting a working model (no errors) with unfinished attics to include vaulted ceilings in two areas of the first floor. See model here.
|
2023-01-20 10:05:31 -0500 | asked a question | Severe error for ASHP with switchover control with OAT Severe error for ASHP with switchover control with OAT Received the following error message. See energy model here. |
2023-01-20 09:40:12 -0500 | commented question | Cannot change age of GSHP I set the age of the home as 2 years, and then wanted to make the system 1 yr. It's almost a new build that we are evalu |
2023-01-19 11:01:32 -0500 | asked a question | Cannot change age of GSHP Cannot change age of GSHP Receive an error message "Age must be less than building age", even when entering an equipment |
2023-01-19 10:12:55 -0500 | edited question | Energy Model Calibration Workflow Energy Model Calibration Workflow With the release of BEOpt v3 and the use of OpenStudio-HPXML for energy modeling, is t |