First time here? Check out the Help page!
2019-10-09 01:10:16 -0500 | received badge | ● Popular Question (source) |
2018-04-09 21:45:59 -0500 | received badge | ● Popular Question (source) |
2017-02-12 00:21:46 -0500 | answered a question | Error in Fresh Air Handling Unit In design builder, when we want to connect more than 2 components to a single Fresh Air Handling Unit there is a need to connect all components to FAHU through same mixer / splitter. Multiple mixers / splitters cause severe errors in simulation. Whenever a component is added the mixer / splitter branch automatically updates to increase in number of connections making more connectors available. See following images. |
2017-02-07 01:35:25 -0500 | asked a question | Zone, Sensible and Total Cooling The final results after annual simulation give me monthly energy consumption for different parameters. Now all the energy is in positive while cooling is with negative sign. Plus, there are three parameters Zone Sensible Cooling, Total Cooling and Sensible Cooling reported. Shall I just mathematically add all kWh energy consumption irrespective of the signs and would that be my monthly energy consumption? Or Do I remove one of the cooling results? Results Shown : https://1drv.ms/i/s!Ase9DtM9ZxGyjB9ek... |
2017-01-30 09:20:32 -0500 | asked a question | Humidity Control in Detailed HVAC When Using the Detailed HVAC do we need to add a humidifier to the Air Handling Unit? Does the software not automatically take the humidity set points from the Activity set? Problem is when I am changing the RH Humdification and Dehumidification set points the results are not giving any changes in energy. |
2017-01-30 09:10:19 -0500 | commented question | Error in Fresh Air Handling Unit @Julien Marrec . Yes I have assigned them by adding several splitters to the FAHUs. Here are the images: https://1drv.ms/f/s!Ase9DtM9ZxGyjAu47... . What do you think should be the solution? |
2017-01-30 08:57:26 -0500 | commented question | Error in Fresh Air Handling Unit @Julien Marrec I checked in the IDF file. Yes there are more than one mixers. But one FAHU is serving more than one zones. So won't it definitely have more than one mixers too? |
2017-01-30 08:36:44 -0500 | commented question | Error in Fresh Air Handling Unit Here's the link to the IDF file of my simulation. |
2017-01-30 08:26:48 -0500 | received badge | ● Autobiographer |
2017-01-30 08:20:15 -0500 | commented question | Error in Fresh Air Handling Unit Where is it in FAHU visually? |
2017-01-30 07:56:40 -0500 | commented question | Error in Fresh Air Handling Unit What do you mean by mixers? You mean the exhaust air fan? |
2017-01-30 07:56:40 -0500 | received badge | ● Commentator |
2017-01-30 00:17:36 -0500 | asked a question | Error in Fresh Air Handling Unit After assigning 32 Fan Coil Units and 3 Fresh Air Handling Units with COPs, simulation is giving error for FAHUs. It says:
What is the solution to this? Because 8 zones are assigned to FAHU1, 8 to FAHU2 and 12 to FAHU3. |
2017-01-24 12:57:11 -0500 | commented question | How to Add 32 FCUs and 3 FAHUs to same building? Ok. I got your point. I will follow the forum guidelines, as I was unaware up till now. |
2017-01-24 09:24:21 -0500 | commented question | How to Add 32 FCUs and 3 FAHUs to same building? But none has been answered yet. |
2017-01-24 02:23:17 -0500 | asked a question | How to add FCUs and FAHUs together? I am using detailed HVAC and have assigned 32 Fan Coil Units (PTAC) to 32 zones of the building I am simulating. Now all the zones are also connected to 3 Fresh Air Handling Units. Problem is when I assign the FCUs and select the zones in zone groups then how do I assign FAHUs to all zones, as they disappear from zone group options because they already are assigned the FCUs? |
2017-01-24 01:10:32 -0500 | asked a question | How to Add 32 FCUs and 3 FAHUs to same building? Dear fellows, I have 32 Fan Coil Units serving 32 zones and 3 Fresh Air Handling Units serving the whole building. I understand adding 32 FCUs (PTACs) with COPs and performance curves to 32 zones. After adding 32 FCUs how will I assign 3 FAHUs to all the zones, as in DB once the zone is in zone group it disappears from the selection option. Waiting for a reply. |
2017-01-24 00:21:45 -0500 | commented answer | OpenStudio vs Design Builder Yes I agree with you. Visit this site: https://designbuilder.co.uk/tutorials/ I am sure this will give you a clear idea of the detailed HVAC systems in Design Builder. |
2017-01-24 00:17:35 -0500 | commented answer | Why is this error coming in detailed HVAC? Yes I just fixed it. Thank you for your reply. |
2017-01-24 00:17:21 -0500 | commented question | Why is this error coming in detailed HVAC? Ok. Thanks for your suggestion |
2017-01-14 23:46:21 -0500 | answered a question | OpenStudio vs Design Builder Both softwares can be used for your purpose, but I would prefer Design Builder. It is less time consuming. In OpenStudio default settings are much more complex than design builder which is more user friendly. Plus OpenStudio model visualization is not possible. In Designbuilder majority settings are already set by default to help simulate multiple times and then make changes according to your needs. Chances of errors are less so it saves your time. As for HVAC system I would suggest using Simple HVAC first, after it completes without errors you can then add the detailed HVAC. To complete a model with standard systems (for building your size) can take me 7-10 days while detailed might take a more than 2 weeks (for complete detailed HVAC). But again it depends how much time you are spending on it. Hope this helps. |
2017-01-14 23:34:13 -0500 | asked a question | Why is this error coming in detailed HVAC? I am entering the detailed HVAC in Design Builder. After entering it is giving the following errors: Can you kindly help me guide why am I having this error? |
2017-01-11 02:01:34 -0500 | commented answer | How to add electric powered detailed HVAC in Design Builder? Dear Dave, Thank you for your response. I am trying to run any template for right now as the simulation is giving errors (something regarding the zone matching...). However your reply has given me a good direction. I am grateful for your support. Regards, Junaid |
2017-01-11 01:59:56 -0500 | commented answer | How to add electric powered detailed HVAC in Design Builder? Dear Banicu, Thank you for your reply. I will look into this. Thanks again for the help. Regards, Junaid |
2017-01-09 23:45:30 -0500 | asked a question | How to add electric powered detailed HVAC in Design Builder? Dear Fellows, I am working on an institutional building model. The building has 5 types of Fan Coil Units serving 32 different zones. It has 3 Fresh Air Handling Units for all zones. The outdoor air enters the FCU whose coils are not connected to any water system rather the heating and cooling coils work with electric power to provide set point temperatures. Refrigerant is circulating in the cooling coil. The air is then supplied to the zone. I don't know how to model this template? Shall I use only a Fan Coil Unit with air inlet and outlet connecting to zone only? Kindly help. |
2016-12-18 04:00:12 -0500 | asked a question | Where to enter the flow rate from vents? Hello fellows, I have the readings for the flow rate(air coming out of vents) for each defined zone. I want to enter this to Design Builder model. Where do I enter this? Kindly reply. Regards. |
2016-12-06 06:03:33 -0500 | commented answer | How to assigning separate Fresh Air Handling Unit with Fan Coil Unit in DB? Great. Your reply was of great help and very useful. Thanks a bundle. |
2016-12-06 00:36:38 -0500 | asked a question | How to assigning separate Fresh Air Handling Unit with Fan Coil Unit in DB? Dear Fellows, The building that I am auditting has 3 separate Fresh Air Handling Units for entire building and Fan Coil Units for each room. I figured out how to assign the FCUs in DB but the problem is i need to assign FAHUs also along with the FCUs. Is it possible? Which tab can I use to assign separately the FAHUs with the FCUs. Please reply. Tonnes of thanks. |
2016-12-03 10:08:34 -0500 | received badge | ● Teacher (source) |
2016-12-03 07:21:13 -0500 | answered a question | Determine COP performance curves in DesignBuilder for an ASHP Hello. I have entered the coefficients also. I did not face any problem. But all my temperatures were positive. I guess may be due to negative low temperature you are facing this problem. |
2016-11-29 03:45:07 -0500 | commented answer | Where to find the editable tab in design builder for adding the coefficients for the performance curves? Thanks a lot. Solved my problem. |
2016-11-28 15:30:25 -0500 | received badge | ● Student (source) |
2016-11-28 09:26:00 -0500 | asked a question | Where to find the editable tab in design builder for adding the coefficients for the performance curves? Hi fellows, I am doing energy analysis of one of the buildings in my institute. I want to enter the calculated coefficients of performance curves. Where do I access the tab in design builder from? Regards |
2016-11-28 09:25:59 -0500 | asked a question | How to access the COP performance curve coefficients? Dear Fellows, I am doing energy analysis of one of the buildings at my institute. How do I access the editable coefficients for the performance curves? Kindly reply as I have tried but I am not finding any options. Regards. |