RMurray's profile - activity

2022-02-16 13:36:35 -0500 received badge  Teacher (source)
2021-12-05 12:04:27 -0500 edited answer Using Custom Setpoint Schedule from File in Resstock

Thanks for your question/update. Would you please say more about whether using a .csv file to establish setpoints seemed

2021-12-05 12:03:22 -0500 answered a question Using Custom Setpoint Schedule from File in Resstock

Thanks for your question/update. Would you please say more about whether using a .csv file to establish setpoints seemed

2021-11-17 11:47:40 -0500 commented question Why is Site:WaterMainsTemperature Correlation from Weather File locked on one temperature for all times and locations?

I've had this issue, too! No way to tell e+ to use the following object to inform the cold water supply temperature at s

2021-11-17 11:44:51 -0500 answered a question Why is Site:WaterMainsTemperature Correlation from Weather File locked on one temperature for all times and locations?

Demonstration of "frozen" Site:MainsWaterTemperature values against the backdrop of outdoor DBT. This despite including

2021-11-17 11:39:06 -0500 commented question Why is Site:WaterMainsTemperature Correlation from Weather File locked on one temperature for all times and locations?

I've had this issue, too! I can’t figure out how to tell e+ to use the following object to inform the cold water supply

2021-11-17 11:00:00 -0500 commented answer Show Tempering Valve as connector

Thanks to both Julien and Aaron!!

2021-11-17 10:48:51 -0500 commented answer Unable to insert a Coil:WaterHeating:AirToWaterHeatPump:Wrapped component into a branch

Thanks for your response, Aaron! I should clarify, though, that the WaterHeater:HeatPump:WrappedCondenser compound objec

2021-11-14 21:09:34 -0500 commented question Why is Site:WaterMainsTemperature Correlation from Weather File locked on one temperature for all times and locations?

I've had this issue, too!

2021-11-14 18:06:01 -0500 edited question Unable to insert a Coil:WaterHeating:AirToWaterHeatPump:Wrapped component into a branch

Unable to insert a Coil:WaterHeating:AirToWaterHeatPump:Wrapped component into a branch I was hoping to account for the

2021-11-14 18:00:54 -0500 asked a question Unable to insert a Coil:WaterHeating:AirToWaterHeatPump:Wrapped component into a branch

Unable to insert a Coil:WaterHeating:AirToWaterHeatPump:Wrapped component into a branch I was hoping to account for the

2021-11-04 15:37:21 -0500 commented answer Importing CBECC-Res model

Oh, well, That's unfortunate. Thanks for your response, Eric.

2021-11-04 15:36:14 -0500 marked best answer Show Tempering Valve as connector

How do I show a tempering valve in a plant loop using EnergyPlus? I can't add it to the connector list, so I'm at a loss. Thanks!

2021-11-04 15:36:14 -0500 received badge  Scholar (source)
2021-11-04 15:35:53 -0500 commented answer Show Tempering Valve as connector

Thanks, Aaron!!

2021-11-04 15:35:14 -0500 edited question Show Tempering Valve as connector

Show Tempering Valve as connector How do I show a tempering valve in a plant loop using EnergyPlus? I can't add it to th

2021-11-04 15:34:06 -0500 edited question Show Tempering Valve as connector

Show Tempering Valve as connector How do I show a tempering valve in a plant loop using EnergyPlus? I can't add it to th

2021-09-07 10:22:15 -0500 commented question Show Tempering Valve as connector

I've tried several times to edit the tags to no avail.

2021-09-07 10:19:21 -0500 edited question Show Tempering Valve as connector

Show Tempering Valve as connector How do I show a tempering valve in a plant loop using EnergyPlus? I can't add it to th

2021-09-07 10:19:21 -0500 received badge  Editor (source)
2021-09-06 23:14:24 -0500 asked a question Show Tempering Valve as connector

Show Tempering Valve as connector How do I show a tempering valve in a plant loop? I can't add it to the connector list,

2021-09-04 07:41:21 -0500 received badge  Student (source)
2021-09-04 07:39:01 -0500 asked a question Importing CBECC-Res model

Importing CBECC-Res model Is it possible to import a CBECC-Res model into EnergyPlus?

2021-08-26 11:06:02 -0500 asked a question why are there so few HPWHs in BCL?

why are there so few HPWHs in BCL? There are two heat pump water heaters that I can find in the BCL: GeoSpring GEH50CNSR

2021-07-22 15:51:48 -0500 commented answer using PNNL models in openstudio

Really? I would have expected to be able to import--since that option is offered by OpenStudio Application.