First time here? Check out the Help page!
2020-08-23 17:07:28 -0500 | commented question | What is the most efficient (or most common) HVAC system for tall office building in tropical desert climate? Many thanks for your reply.. it was very helpful |
2020-01-20 15:12:43 -0500 | received badge | ● Popular Question (source) |
2019-07-23 04:03:29 -0500 | commented answer | Where to find epw files associated with the future climate scenarios? I used CCWeatherGen for free, and it was helpful. Thank you |
2019-07-16 13:59:10 -0500 | commented question | In what cases real empirical experiments can be replaced by computer simulations? @JasonGlazer Many thanks for your informative answer. |
2019-07-12 10:02:45 -0500 | commented question | In what cases real empirical experiments can be replaced by computer simulations? For instance, I'm using EnergyPlus, THERM, etc. to develop and compare many high rise building prototypes to see what de |
2019-07-12 10:01:38 -0500 | commented question | In what cases real empirical experiments can be replaced by computer simulations? For instance, I'm using EnergyPlus, THERM, etc. to develop and compare many high rise building prototypes to see what de |
2019-07-12 10:00:48 -0500 | commented question | In what cases real empirical experiments can be replaced by computer simulations? For instance, I'm using EnergyPlus, THERM, etc. to develop and compare many high rise building prototypes to see what de |
2019-07-12 09:59:15 -0500 | edited question | In what cases real empirical experiments can be replaced by computer simulations? In what cases real empirical experiments can be replaced by computer simulations? Computer simulations deal with simplif |
2019-07-12 09:57:56 -0500 | commented question | In what cases real empirical experiments can be replaced by computer simulations? For instance, I'm using EnergyPlus, THERM, etc. to develop and compare many high rise building prototypes to see what de |
2019-07-12 05:46:43 -0500 | edited question | Would you recommend literature sources comparing international standards regarding minimum climatic performance requirements for curtain walls and windows? Would you recommend literature sources comparing international standards regarding minimum climatic performance requirem |
2019-07-12 05:45:47 -0500 | edited question | Would you recommend literature sources comparing international standards regarding minimum climatic performance requirements for curtain walls and windows? What literature sources compare international standards regarding minimum climatic performance requirements for curtain |
2019-07-12 04:55:12 -0500 | edited question | In what cases real empirical experiments can be replaced by computer simulations? In what cases real empirical experiments can be replaced by computer simulations? Computer simulations deal with simplif |
2019-07-12 04:53:02 -0500 | asked a question | In what cases real empirical experiments can be replaced by computer simulations? In what cases real empirical experiments can be replaced by computer simulations? Computer simulations deal with simplif |
2019-07-12 04:02:51 -0500 | asked a question | Would you recommend literature sources comparing international standards regarding minimum climatic performance requirements for curtain walls and windows? What literature sources compare international standards regarding minimum climatic performance requirements for curtain |
2019-07-05 22:30:21 -0500 | commented answer | Where to find epw files associated with the future climate scenarios? thanks for sharing. This page (http://www.energy.soton.ac.uk/ccweathergen/) refers to this (http://www.energy.soton.ac.u |
2019-07-05 22:10:48 -0500 | commented answer | Where to find epw files associated with the future climate scenarios? Thank you for sharing. Is there any FREE option for students. I only need data for ONE location. |
2019-07-05 22:09:49 -0500 | commented answer | Where to find epw files associated with the future climate scenarios? Thanks for sharing. I'm a student, and this is really expensive. (AMY FORMAT First Scenario € 240,00 Each Additional Sce |
2018-10-21 19:00:30 -0500 | asked a question | Where to find epw files associated with the future climate scenarios? Where to find epw files associated with the future climate scenarios? There are scenarios about the future of climate es |
2018-06-06 12:12:50 -0500 | commented answer | PROBLEM WITH TOLERANCE @rraustad Thanks for your reply. Actually I don't work directly with OpenStudio/EnergyPlus. I use Grasshopper/Honeybee. |
2018-06-05 06:28:58 -0500 | commented answer | PROBLEM WITH TOLERANCE I'm using Grasshopper/Honeybee and I don't know how I can change the tolerance value. As far as I know it's not included |
2018-06-05 06:28:09 -0500 | commented answer | PROBLEM WITH TOLERANCE I'm using Grasshopper/Honeybee and I don't know how I can change the tolerance value. As far as I know it's not included |
2018-06-05 06:28:09 -0500 | received badge | ● Commentator |
2018-06-05 06:19:48 -0500 | commented answer | How do I solve failure to converge during warmup error? I'm using Grasshopper/Honeybee and I don't know how I can change the tolerance value. As far as I know it's not included |
2018-05-26 04:50:53 -0500 | edited question | Any suggestions about setting an old conventional HVAC system (for tall building in hot climates)? Settings of old conventional HVAC systems (for tall buildings in hot climates) This is in connection with my other quest |
2018-05-25 13:09:42 -0500 | edited question | UnmetHours.com content citation UnmetHours content citation I've asked a number of questions at this site (UnmetHours.com) and received helpful replies. |
2018-05-25 13:08:39 -0500 | edited question | What is the most efficient (or most common) HVAC system for tall office building in tropical desert climate? What is the most efficient HVAC system for tall office building in tropical desert climate? Working on a research projec |
2018-05-25 13:04:04 -0500 | asked a question | UnmetHours.com content citation UnmetHours content citation I've asked a number of questions at this site (UnmetHours.com) and received helpful replies. |
2018-05-22 23:41:13 -0500 | received badge | ● Organizer (source) |
2018-05-22 23:39:43 -0500 | edited question | Any suggestions about setting an old conventional HVAC system (for tall building in hot climates)? Settings of old conventional HVAC systems for tall buildings in hot climates This is in connection with my other questio |
2018-05-22 23:39:25 -0500 | edited question | Any suggestions about setting an old conventional HVAC system (for tall building in hot climates)? Old HVAC systems settings? This is in connection with my other question here Doing a research project on tall buildings |
2018-05-22 19:28:32 -0500 | edited question | Any suggestions about setting an old conventional HVAC system (for tall building in hot climates)? Old HVAC systems settings? This is in connection with my other question here Doing a research project on tall buildings |
2018-05-22 19:27:34 -0500 | edited question | Any suggestions about setting an old conventional HVAC system (for tall building in hot climates)? Old HVAC systems settings? This is in connection with my other question at: link text Doing a research project on tall |
2018-05-22 19:25:37 -0500 | edited question | Any suggestions about setting an old conventional HVAC system (for tall building in hot climates)? Old HVAC systems settings? This is in connection with my other question at: link text Doing a research project on tall |
2018-05-22 19:24:38 -0500 | asked a question | Any suggestions about setting an old conventional HVAC system (for tall building in hot climates)? Old HVAC systems settings? This is in connection with my other question at: link text Doing a research project on tall |
2018-05-07 07:13:34 -0500 | commented question | What is appropriate heating and cooling thermostat set points for office building? It's a tall office building in tropical desert climate of Dubai (I edited the description of the question as well). |
2018-05-07 07:12:30 -0500 | edited question | What is appropriate heating and cooling thermostat set points for office building? What is appropriate heating and cooling thermostat set points for office building? What is appropriate heating and cooli |
2018-05-06 19:10:32 -0500 | asked a question | What is appropriate heating and cooling thermostat set points for office building? What is appropriate heating and cooling thermostat set points for office building? What is appropriate heating and cooli |
2018-04-23 07:33:12 -0500 | commented answer | How to modeling the ceiling void ? I read this discussion and this one but it's still unclear to me how to model large concrete beams (with significant th |
2018-04-19 06:04:39 -0500 | edited question | What is the most efficient (or most common) HVAC system for tall office building in tropical desert climate? What is the most efficient HVAC system for tall office building in tropical desert climate? Working on a research projec |
2018-04-19 05:43:19 -0500 | edited question | What is the most efficient (or most common) HVAC system for tall office building in tropical desert climate? What is the most efficient HVAC system for tall office building in tropical desert climate? Working on a research projec |
2018-04-18 13:16:37 -0500 | edited question | What is the most efficient (or most common) HVAC system for tall office building in tropical desert climate? What is the most efficient HVAC system for tall office building in tropical desert climate? Working on a research projec |
2018-04-18 13:15:02 -0500 | edited question | What is the most efficient (or most common) HVAC system for tall office building in tropical desert climate? What is the most efficient HVAC system for tall office building in tropical desert climate? Working on a research projec |
2018-04-18 13:12:43 -0500 | edited question | What is the most efficient (or most common) HVAC system for tall office building in tropical desert climate? What is the most efficient HVAC system for tall office building in tropical desert climate? I'm working on a research pr |
2018-04-18 13:12:32 -0500 | edited question | What is the most efficient (or most common) HVAC system for tall office building in tropical desert climate? What is the most efficient HVAC system for tall office building in tropical desert climate? I'm working on a research pr |
2018-04-18 13:11:54 -0500 | edited question | What is the most efficient (or most common) HVAC system for tall office building in tropical desert climate? What is the most efficient HVAC system for tall office building in tropical desert climate? I'm working on a research pr |
2018-04-18 13:08:25 -0500 | asked a question | What is the most efficient (or most common) HVAC system for tall office building in tropical desert climate? What is the most efficient HVAC system for tall office building in tropical desert climate? I'm working on a research pr |
2018-01-15 02:11:35 -0500 | commented answer | False ceiling: plenum or a layer of air in construction? (in EnergyPlus) Thank you for your reply. In the discussion that you mentioned, there are advantages and disadvantages listed for each s |
2018-01-14 11:56:00 -0500 | edited question | False ceiling: plenum or a layer of air in construction? (in EnergyPlus) False ceiling: plenum or a layer of air in construction? (in EnergyPlus) I want to simulate a room with false ceiling in |
2018-01-14 11:50:51 -0500 | edited question | False ceiling: plenum or a layer of air in construction? (in EnergyPlus) False ceiling: plenum or layer of air in construction? (in EnergyPlus) I want to simulate a room with false ceiling in E |