Question-and-Answer Resource for the Building Energy Modeling Community
Get started with the Help page
Ask Your Question

student's profile - activity

2022-12-18 22:14:32 -0500 received badge  Famous Question (source)
2022-06-28 04:04:53 -0500 received badge  Notable Question (source)
2022-01-23 15:13:55 -0500 received badge  Popular Question (source)
2021-05-24 04:56:42 -0500 received badge  Supporter (source)
2021-03-27 15:20:49 -0500 commented answer Some confusions about Ground Source Heat Pump in OS

I also uploaded a picture of the most important info about water in the Evap cooler.

2021-03-27 15:20:12 -0500 commented answer Some confusions about Ground Source Heat Pump in OS

@wjsjch would you be able to send a screenshot of the flow you get in Var Spd Pump (your 0.00135m3/s) to sebastien.devri

2021-03-27 15:18:02 -0500 commented answer Some confusions about Ground Source Heat Pump in OS

@wjsjch would you be able to send a screenshot of the flow you get in Var Spd Pump (your 0.00135m3/s) to sebastien.devri

2021-03-26 14:40:45 -0500 received badge  Commentator
2021-03-26 14:40:45 -0500 commented answer Some confusions about Ground Source Heat Pump in OS

I understand what you say, but what we have is an zero flow in the source loop the entire year. There is well flow in th

2021-03-26 13:57:53 -0500 commented answer Some confusions about Ground Source Heat Pump in OS

@JKavanaugh I understand what you are saying but how can it be possible that the source loop with ground heatexchanger h

2021-03-26 11:37:25 -0500 commented answer Some confusions about Ground Source Heat Pump in OS

little remark if you don't make separate loops you will need to take the right setpoint manager. Because a scheduled set

2021-03-26 10:44:28 -0500 commented answer Some confusions about Ground Source Heat Pump in OS

no, we have 3 loops. 1 source loop and one cooling and one heating loop. I will upload my file so you can see what we di

2021-03-26 10:42:48 -0500 commented answer Some confusions about Ground Source Heat Pump in OS

no, we have 3 loops. 1 source loop and one cooling and one heating loop. I will upload my file so you can see what we di

2021-03-26 07:23:14 -0500 edited answer Some confusions about Ground Source Heat Pump in OS

We also made a model with a ground heatexchanger. It is best that you create to separated loops one for heating and one

2021-03-26 07:15:37 -0500 received badge  Rapid Responder (source)
2021-03-26 07:15:37 -0500 answered a question Some confusions about Ground Source Heat Pump in OS

We also made a model with a ground heatexchanger. It is best that you create to separated loops one for heating and one

2021-03-14 15:12:34 -0500 commented question add zone mixing object

@Aaron Boranian Yes this is the object out of the BCL.

2021-03-14 05:37:05 -0500 edited question add zone mixing object

add zone mixing object Hello, I am a student working in OS (3.1.0) modelling a residential building. To have an balanced

2021-03-14 05:06:44 -0500 asked a question add zone mixing object

add zone mixing object Hello, I am a student working in OS (3.1.0) modelling a residential building. To have an balanced

2021-03-13 03:41:06 -0500 edited question fluid to fluid heat exchanger

fluid to fluid heat exchanger Hello I am a thesis student working in OS 3.1.0. We have by comparing the fluid heat excha

2021-03-13 03:26:34 -0500 edited question fluid to fluid heat exchanger

fluid to fluid heat exchanger Hello I am a thesis student working in OS 3.1.0. We have by comparing the fluid heat excha

2021-03-13 03:25:14 -0500 edited question fluid to fluid heat exchanger

fluid to fluid heat exchanger Hello I am a thesis student working in OS 3.1.0. We have by comparing the fluid heat excha

2021-03-11 12:54:12 -0500 asked a question fluid to fluid heat exchanger

fluid to fluid heat exchanger Hello I am a thesis student working in OS 3.1.0 and we have by comparing the fluid heat ex

2021-03-08 04:34:37 -0500 asked a question ground heatexchanger

ground heatexchanger I am a master student working with openstudio 2.7.0. I have some weird results in my loop with the

2021-03-08 04:20:27 -0500 asked a question Floor cooling water temperature too hot and condensation

Floor cooling water temperture to hot and condensation I am a Master student checking the robustness of a building with

2021-02-28 03:56:37 -0500 received badge  Organizer (source)
2021-02-28 03:54:51 -0500 edited question cooling loop to hot with heat exchanger fluid to fluid

cooling loop to hot with heat exchanger fluid to fluid I am a student working on my thesis, I must evaluated the robustn

2021-02-28 03:54:41 -0500 edited question cooling loop to hot with heat exchanger fluid to fluid

cooling loop to hot with heat exchanger fluid to fluid I am a student working on my thesis, I must evaluated the robustn

2021-02-28 03:00:45 -0500 edited question cooling loop to hot with heat exchanger fluid to fluid

water loops to hot or to cold I am a student working on my thesis, I must evaluated the robustness of a building with OS

2021-02-28 02:23:41 -0500 commented question Design Specification Outdoor air Object name blank

@julien Marrec, I have made a design specification outdoor air object with all values zero does this gave the same resul

2021-02-28 02:23:29 -0500 commented question Design Specification Outdoor air Object name blank

julien, I have hard sized the minimum and maximum outdoor air Flow rate but still get the warnings and severe error. Wha

2021-02-28 02:23:10 -0500 commented question Design Specification Outdoor air Object name blank

@julien Marrec, I have hard sized the minimum and maximum outdoor air Flow rate but still get the warnings and severe er

2021-02-28 02:22:15 -0500 commented question Design Specification Outdoor air Object name blank

@julien, I have made a design specification outdoor air object with all values zero does this gave the same results as d

2021-02-26 15:09:33 -0500 asked a question cooling loop to hot with heat exchanger fluid to fluid

water loops to hot or to cold I am a student working on my thesis, I must evaluated the robustness of a building with OS

2021-02-26 14:53:59 -0500 commented question Design Specification Outdoor air Object name blank

I have made a design specification outdoor air object with all values zero does this gave the same results as deleting t

2021-02-24 01:17:01 -0500 commented question Design Specification Outdoor air Object name blank

Tank you, to look into the problem and post the problem at OS. I have for a test set all the auto-sized equipment to har

2021-02-18 07:05:56 -0500 commented question Design Specification Outdoor air Object name blank

Julien, In this Wetransfer link you can find our model 11-49(error) and the error file on this link. I have implemented

2021-02-18 07:05:19 -0500 commented question Design Specification Outdoor air Object name blank

Julien, In this Wetransfer link you can find our model 11-49(error) and the error file on this link. I have implemented

2021-02-18 07:04:58 -0500 commented question Design Specification Outdoor air Object name blank

Julien, In this Wetransfer link you can find our model 11-49(error) and the error file on this link. I have implemented

2021-02-18 07:02:18 -0500 commented question Design Specification Outdoor air Object name blank

Julien, In this Wetransfer link you can find our model 11-49(error) and the error file on this link. I have implemented

2021-02-18 07:01:13 -0500 commented question Design Specification Outdoor air Object name blank

Julien, In this Wetransfer link you can find our model 11-49(error) and the error file link text. I have implemented alr

2021-02-17 15:18:55 -0500 commented question Design Specification Outdoor air Object name blank

Julien, I have hard sized the minimum and maximum outdoor air Flow rate but still get the warnings and severe error. Wha

2021-02-17 13:24:13 -0500 edited question Design Specification Outdoor air Object name blank

Design Specification Outdoor air Object name blank I am a student working on my thesis. I am modelling a building in OS

2021-02-17 13:21:08 -0500 commented question Design Specification Outdoor air Object name blank

Julien, the diffusers are hard sized and I still get the error? How does this come?

2021-02-16 15:34:38 -0500 edited question Design Specification Outdoor air Object name blank

Design Specification Outdoor air Object name blank I am a student working on my thesis. I am modelling a building in OS

2021-02-16 15:33:06 -0500 received badge  Editor (source)
2021-02-16 15:33:06 -0500 edited question Design Specification Outdoor air Object name blank

Design Specification Outdoor air Object name blank I am a student working on my thesis. I am modelling a building in OS

2021-02-16 08:41:41 -0500 received badge  Student (source)
2021-02-15 17:17:10 -0500 asked a question floor cooling and floor heating with borehole

floor cooling and floor heating with borehole I am a master student working on my thesis. I am modelling a building in O

2021-02-15 17:17:04 -0500 asked a question Design Specification Outdoor air Object name blank

Design Specification Outdoor air Object name blank I am a student working on my thesis. I am modelling a building in OS