First time here? Check out the Help page!
2022-02-01 20:04:51 -0500 | received badge | ● Notable Question (source) |
2020-04-10 01:20:56 -0500 | received badge | ● Notable Question (source) |
2019-08-29 07:02:03 -0500 | received badge | ● Popular Question (source) |
2018-11-02 19:39:31 -0500 | received badge | ● Popular Question (source) |
2018-06-27 15:27:44 -0500 | received badge | ● Popular Question (source) |
2017-10-04 19:26:17 -0500 | answered a question | calculate energy consumed in a house in energy plus I also believe that Matthew Steen is right for starting with BEopt for modeling the house. BEopt is easy to use for the |
2017-10-04 19:20:08 -0500 | asked a question | Data center models Data center models Hi, I am looking to model the data centers with energyplus with its feature of modeling data centers |
2017-10-04 19:16:46 -0500 | commented answer | Modeling Data Centers in EnergyPlus Hi all, I am also looking to model the data centers in EnergyPlus. Has the prototype models of data centers released fo |
2017-07-12 16:36:02 -0500 | asked a question | Running HVAC in rated power when on in EnergyPlus? Running HVAC in rated power when on in EnergyPlus? Hi all, I am trying to optimize the energy consumption of the house s |
2017-06-13 12:11:48 -0500 | asked a question | Equivalent thermal R and C of house Equivalent thermal R and C of house Hi all, I have developed an EnergyPlus house model using BEopt. I am trying to use a |
2017-01-18 07:48:40 -0500 | commented answer | Run EnergyPlus from python? @Julien Marrec and @Jamie Bull. Thanks a lot. That helped me a lot. |
2017-01-17 15:40:03 -0500 | asked a question | Run EnergyPlus from python? I am confused to run energyplus from python script using I have tried: which runs the energyplus without weather file. But I am not able to pass weather file as argument. |
2016-12-15 19:13:05 -0500 | commented question | Connect Python and BCVTB I am trying system command actor to communicate BCVTB and python. But I am not sure how to proceed in python script. Can you share any example of that? Thanks in advance |
2016-12-15 12:08:53 -0500 | received badge | ● Editor (source) |
2016-12-15 12:05:09 -0500 | asked a question | Connect Python and BCVTB I am trying to connect energyplus to python via BCVTB . Is there a sample python code to connect to BCVTB? Thanks, |
2016-11-15 15:06:30 -0500 | commented question | Zone temperature beyond heating setpoint temperature Thanks David. When the internal loads are removed, EMS and heating setpoints works fine. So, What should I do to maintain a house in constant heating setpoint temperature with the load. I would like to use single heating mode, without turning the cooling on in winter period. |
2016-11-15 12:55:18 -0500 | asked a question | Zone temperature beyond heating setpoint temperature I am new in EnergyPlus and I wanted to set a temperature of a house model at specific heating and cooling setpoint. When I use single heating mode in the example file Packaged Heat Terminal Pump and use a weather file, the zone temperature goes beyond the heating setpoint temperature even if the heating coils are turned off. I even tried by turning off the fan, but the temp increases in the middle of the day beyond my heating setpoint. I also tried the EMS and tried to give a deadband in heating setpoint. I donot understand why my zone temperature is above heating setpoint when outdoor temperature is lower than the heating setpoint and my heating coils off. I hope you could help me in this confusion. |
2016-09-28 09:35:47 -0500 | received badge | ● Student (source) |
2016-09-28 08:31:02 -0500 | asked a question | EnergyPlus and BCVTB interface problem I am new to BCVTB and I tried to change the example schedule problem of BCVTB. Instead of controlling temperature, I tried to control the lights. For that, I created an object named 'control lights' in external interface and included that object in schedule of Lights. In output variable as well, I created an object with the key value as 'control lights' and variable name as 'Schedule Value' in the first case and ' Lights Electric Power' in the second case.I also changed in variable.cfg file as well in both cases. I need the Lights Electric Power data to be used in Control actions but I am unable to get it. Am i missing something?? |