CRHavis's profile - activity

2018-01-17 22:00:54 -0500 marked best answer Why is there no heat rejection energy from air cooled VRF?

Is it always included in the (air cooled) compressor energy?

There is cooling energy, but I would expect to see some condenser fan energy under heat rejection. I did not see any way to connect condenser fans, so I assume that the assumption was the condenser fan energy is always rolled up with the compressor.

Openstudio 2.3.0

2018-01-16 17:59:03 -0500 asked a question Why is there no heat rejection energy from air cooled VRF?

Why is there no heat rejection energy from air cooled VRF? Is it always included in the (air cooled) compressor energy?

2016-11-04 16:13:05 -0500 commented answer How to use Chiller:Electric:ReformulatedEIR in openstudio

Does such a measure exist already?(I'm not a Ruby or E+ Guru) Any reason Chiller:Electric:ReformulatedEIR is not supported?

2016-11-04 15:33:39 -0500 asked a question How to use Chiller:Electric:ReformulatedEIR in openstudio

I have manufacturer's ReformulatedEIR curves. How can I get Chiller:Electric:ReformulatedEIR in my openstudio plant loop?

2016-10-18 17:37:38 -0500 received badge  Supporter (source)
2016-10-18 17:37:28 -0500 received badge  Scholar (source)
2016-10-18 14:46:59 -0500 asked a question OpenStudio grid view losing column alignment

Does loss of column alignment indicate a problem in my model, or is this a known glitch? I didn't find anything or didn't know what to search. Please see image: image description

2016-09-26 14:19:51 -0500 commented question Measure not working: Replace Exterior Window Construction with a Different Construction from the Model

Here is a link to the model. https://www.transferbigfiles.com/cb47... I did not see errors when applying the measure.

2016-09-23 11:23:23 -0500 received badge  Student (source)
2016-09-22 16:37:34 -0500 asked a question Measure not working: Replace Exterior Window Construction with a Different Construction from the Model

I am trying to use the measure "Replace Exterior Window Construction with a Different Construction from the Model" to do just what it says.

I have one construction that I want to swap out for a PAT analysis.

Measure runs, identifies the existing construction, and reports replacing 0 ft^2...


I found the problem. It is ignoring inherited constructions. It only replaces constructions entered at the space level.

2016-09-22 14:10:45 -0500 commented answer Can I create a HVAC template in Openstudio?

I am surprised to find out NREL has not written such a measure. It would be very useful for initial PAT analysis when evaluating systems.