2023-09-10 13:31:05 -0500 | commented answer | SEER and HSPF in E+/Design Builder Here is my email address, if you don't mind sharing the file: |
2023-08-27 00:38:52 -0500 | commented question | SEER and HSPF in E+/Design Builder There seem to be no difference in SEER/HSPF between 9.4.0 and v23.1, but V23.1 also reports SEER2/HSPF2. Thanks for the |
2023-08-25 09:10:42 -0500 | commented question | SEER and HSPF in E+/Design Builder Richard, thank you very much for looking into this! I did not review the file yet, but will do that asap. To answer your |
2023-08-21 20:07:41 -0500 | commented question | SEER and HSPF in E+/Design Builder Hi Richard, Here is the link to IDF and manufacturer data: https://jordanskala-my.sharepoint.com/:f:/p/adavidovic/Eo4x |
2023-08-10 10:35:21 -0500 | commented answer | SEER and HSPF in E+/Design Builder Here is my email address, if you don't mind sharing the file: ananeddav@hotmail.com. |
2023-08-10 10:32:09 -0500 | commented question | SEER and HSPF in E+/Design Builder Hi Richard, Yes , I entered the evaporator fan power w/cfm for this specific HP model. This increased SEER a little bit, |
2023-08-10 10:09:10 -0500 | commented answer | SEER and HSPF in E+/Design Builder Sure, I would appreciate that very much. Could you share the link here, or should I provide my email address? I'm just t |
2023-08-10 08:59:37 -0500 | commented answer | SEER and HSPF in E+/Design Builder Hi Jim, Thanks for your response! I read that SEER for Multi Speed DX coil and HSPF are supposed to be calculated as we |
2023-08-09 21:06:25 -0500 | asked a question | SEER and HSPF in E+/Design Builder SEER and HSPF in E+/Design Builder Has anyone observed a big difference between SEER/HSPF reported in the Equipment Summ |
2019-09-06 10:30:47 -0500 | marked best answer | DOAS enhancements in eQUEST ? A pre-conference workshop at ASHRAE BPA 2017 will present new features of eQUEST and DOE-2, including a new stand-alone dedicated outdoor system and a detailed variable refrigerant flow system model. Are there any details available about the most recent DOAS enhancement in eQUEST? Any information on when a new version of eQUEST will be released? Thanks, |
2019-03-06 12:23:20 -0500 | commented answer | DOAS enhancements in eQUEST ? Great, Thank you! |
2019-03-06 08:52:22 -0500 | commented answer | DOAS enhancements in eQUEST ? The most recent version of eQuest build 7175 was released in Oct 2018. It was my understanding that this version was sup |
2018-11-27 05:56:36 -0500 | received badge | ● Notable Question (source) |
2018-10-28 12:00:40 -0500 | commented answer | DesignBuilder simulation-time Thank you, Dave. I've raised the ticket. I'm just really looking for some rough estimate, that would help me figure out |
2018-10-27 06:23:05 -0500 | commented answer | DesignBuilder simulation-time I takes 7 minutes to run the IDF in EP Launch, which is two times faster than running the same model in DesignBuilder. I |
2018-10-25 09:26:55 -0500 | commented answer | DesignBuilder simulation-time Thank you, Dave. I've raised the ticket. I'm just really looking for some rough estimate, that would help me figure out |
2018-10-24 18:03:24 -0500 | asked a question | DesignBuilder simulation-time DesignBuilder simulation-time Hi All, How much time do you expect a simulation (15,000 sf, 20 zone, 16 HVAC systems, 6 |
2017-08-30 19:55:32 -0500 | commented answer | Thermal Load too low in the OpenStudio / EnergyPlus Geraldo, Have you arrived to final answer to this question? I’ve noticed in several E+ models that the HVAC systems hav |
2017-08-29 19:55:23 -0500 | commented question | Cooling Load for Interzone Wall negative? For this particular zone, the zone level cooling peak occurs at 15:00 pm. The cooling peak does not occur at the same ti |
2017-08-28 15:19:58 -0500 | edited question | Cooling Load for Interzone Wall negative? Cooling Load for Interzone Wall negative? I noticed that the auto-sized air flow of my VAV system is much lower that the |
2017-08-28 15:07:17 -0500 | edited question | Cooling Load for Interzone Wall negative? Cooling Load for Interzone Wall negative? I noticed that the auto-sized air flow of my VAV system is much lower that the |
2017-08-28 14:59:28 -0500 | commented question | Cooling Load for Interzone Wall negative? The model geometry was generated in OpenStudio. Construction of interior walls in E+ is : 19mm gypsum board, Wall air sp |
2017-08-28 14:50:17 -0500 | edited question | Cooling Load for Interzone Wall negative? Cooling Load for Interzone Wall negative? I noticed that the auto-sized air flow of my VAV system is much lower that the |
2017-08-28 14:49:18 -0500 | edited question | Cooling Load for Interzone Wall negative? Cooling Load for Interzone Wall negative? I noticed that the auto-sized air flow of my VAV system is much lower that the |
2017-08-28 14:49:08 -0500 | edited question | Cooling Load for Interzone Wall negative? Cooling Load for Interzone Wall negative? I noticed that the auto-sized air flow of my VAV system is much lower that the |
2017-08-27 16:43:52 -0500 | edited question | Cooling Load for Interzone Wall negative? Cooling Load for Interzone Wall negative? I noticed that the auto-sized air flow of my VAV system is much lower that the |
2017-08-27 16:39:06 -0500 | edited question | Cooling Load for Interzone Wall negative? Cooling Load for Interzone Wall negative? I noticed that the auto-sized air flow of my VAV system is much lower that the |
2017-08-27 16:35:28 -0500 | edited question | Cooling Load for Interzone Wall negative? Cooling Load for Interzone Wall negative? I noticed that the auto-sized air flow of my VAV system is much lower that the |
2017-08-27 16:33:22 -0500 | edited question | How to specify Supply Air flow at VAV How to specify Supply Air flow at VAV I’m trying to model a VAV system with reheat in E+, which I believe should not be |
2017-08-27 16:31:52 -0500 | edited question | Cooling Load for Interzone Wall negative? Cooling Load for Interzone Wall negative? I noticed that the auto-sized air flow of my VAV system is much lower that the |
2017-08-27 16:31:45 -0500 | edited question | Cooling Load for Interzone Wall negative? Cooling Load for Interzone Wall negative? I noticed that the auto-sized air flow of my VAV system is much lower that the |
2017-08-27 16:31:45 -0500 | received badge | ● Editor (source) |
2017-08-27 16:31:33 -0500 | edited question | Cooling Load for Interzone Wall negative? Cooling Load for Interzone Wall negative? I noticed that the auto-sized air flow of my VAV system is much lower that the |
2017-08-27 16:25:54 -0500 | asked a question | Cooling Load for Interzone Wall negative? Cooling Load for Interzone Wall negative? I noticed that the auto-sized air flow of my VAV system is much lower that the |
2017-08-27 15:11:56 -0500 | commented answer | How to specify Supply Air flow at VAV Yes, I did specify Supply Fan Maximum Flow Rate and Supply Fan Minimum Flow Rate. System Availability Schedule should b |
2017-08-26 19:33:42 -0500 | answered a question | Which paramters do we need to change while using a new weather file in energyplus? Did you make any changes to Site:Location and SizingPeriod:DesignDay? |
2017-08-24 21:59:31 -0500 | commented answer | DOAS enhancements in eQUEST ? Yes, this helps. Thank you! |
2017-08-24 21:59:31 -0500 | received badge | ● Commentator |
2017-08-23 21:27:27 -0500 | asked a question | DOAS enhancements in eQUEST ? DOAS enhancements in eQUEST ? A pre-conference workshop at ASHRAE BPA 2017 will present new features of eQUEST and DOE-2 |
2017-08-23 10:25:59 -0500 | commented question | How to specify Supply Air flow at VAV Maybe I need to rephrase my question a bit to make it less specific to this project. Let’s assume that a VAV system is c |
2017-08-22 09:14:01 -0500 | commented question | How to specify Supply Air flow at VAV Thank you for reminding me of the rules. Yes, this is E+ 8.0. The model was built a few years ago, and I’m trying to fin |
2017-08-21 21:35:36 -0500 | asked a question | How to specify Supply Air flow at VAV How to specify Supply Air flow at VAV Hi Everyone, I’m trying to model a VAV system with reheat in E+, which I believe |
2017-08-08 11:51:03 -0500 | received badge | ● Popular Question (source) |
2017-05-27 06:09:02 -0500 | received badge | ● Nice Question (source) |
2017-05-16 09:44:11 -0500 | commented answer | How to model process cooling with ASHRAE 90.1 App G Baseline system 5 or 6 Agreed. Modeling the same rated cooling efficiency with an auto-sized chiller capacity in the Baseline model should be g |
2017-05-15 21:09:40 -0500 | answered a question | How to model process cooling with ASHRAE 90.1 App G Baseline system 5 or 6 Hi, It is a bit unclear how the space cooling is provided in the actual design (proposed model)? I assume that the spac |
2017-01-18 09:34:17 -0500 | commented answer | OpenStudio vs Design Builder Matthew, thank you for your detailed response. I was able to create some very complex geometry quickly using SketchUp/OpenStudio, but I didn't try to write any OpenStudio measures, and that should be my next step. Most of the projects I do are LEED or code compliance models, where equipment autosizing is not allowed. It sounds that OpenStudio measures would allow me to create HVAC systems for certain zones, but I would still have to manually specify individual equipment capacities/efficiencies etc., according to the mechanical schedules. Is that correct? |
2017-01-18 08:59:15 -0500 | commented answer | OpenStudio vs Design Builder Dave, thanks for replying to my post. As soon as I can make some time in my schedule, I will download a free 30day trial of DesignBuilder. Would the 30day trial give me an access to Engineering Plus/Pro version that have Scripting included? |
2017-01-18 08:34:17 -0500 | commented answer | OpenStudio vs Design Builder Thanks for sharing your experience. From your response, it sounds like Design Builder is very similar to eQuest. With eQuest, simple HVAC is created in Wizard, and then more detailed input or additional HVAC systems are created in Detailed mode. I found that ability to visually see HVAC and respective zone is a huge time saver, especially when I have to go back to old models to make some quick changes. Can you share a few examples of the more complex HVAC when writings scripts in DB would be necessary? Thanks again! |
2017-01-14 08:51:59 -0500 | asked a question | OpenStudio vs Design Builder I’m trying to figure out if there are some advantages in using Design Builder over OpenStudio. For example, would Design Builder allow me to create some more complex HVAC systems (such as DOAS with radiant slabs, or central ground source heat pump, etc.) and export an IDF file including the detailed HVAC components? Can you guys share your thoughts about advantages/disadvantages of Design Builder over OpenStudio? I’m asking this question because I need some reality check in terms of time I spend on my models and would greatly appreciate any suggestion. I used OpenStudio for several projects, but found specifying HVAC parameters in Open Studio time consuming and difficult (a lot of errors). To avoid many errors in HVAC, I would just create geometry and assign attributes in OpenStudio, and create all HVAC systems directly in IDF file by using E+. The building size I typically have to model is 150,000 sf to 200,000 sf. How many of HVAC components/ controls, in general, are you guys able to specify in Open Studio before switching to E+ ( idf) for this building size? Also, how much time roughly does it take for you to complete a model with standard systems ( e.g. VAV w/ boiler chiller) and a model with a more complex system ( e.g., radiant slabs with with DOAS w/ DCV providing ventilation air directly to the spaces)? Let’s assume that the building has 150,000 sq.ft and a simple rectangular shape. |